CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Cooler Master MWE Gold 850 V4
Serial Number-
Lab IDCM85003435
Certification ID263435
  • Test Result Report ID: 26PS3435A
  • Certificate Issue Date: Oct 8, 2026
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
This product certification body is accredited by CYS-CYSAB (Cyprus Accreditation Body) under accreditation number C010 as a Product Certification Body, in accordance with the recognized International Standard ISO/IEC 17065:2012 “Conformity assessment — Requirements for bodies certifying products, processes and services”. The accreditation covers the ETA and LAMBDA certification of power supply units and of multimedia (information technology) equipment, and the PHI certification of cooling fans, each as a Type 1a scheme according to ISO/IEC 17067. Certifications outside that scope are not covered by the accreditation. This accreditation demonstrates technical competence for a defined scope and the operation of a management system.
Aristeidis Bitziopoulos, Certification Body General Manager
CYS-CYSAB accreditation symbol, ISO/IEC 17065:2012
No. of Accred.: C010
PRODUCT CERTIFICATION

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

838485868788899091929394Average efficiency (%)84.5089.9290.9890.5489.6885.7991.6592.9793.0092.520-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 83115V230V
838485868788899091929394Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 83115V230V
0.740.760.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0.9370.9830.9980.9980.9990.7770.9290.9700.9840.9910-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.74115V230V
0.740.760.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.74115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %200 / 20084.50%85.79%0.9370.777
20-<40 %318 / 31889.92%91.65%0.9830.929
40-<60 %319 / 31990.98%92.97%0.9980.970
60-<80 %318 / 31890.54%93.00%0.9980.984
80-100 %326 / 32689.68%92.52%0.9990.991
70-100 % (High-Load)486 / 48689.91%92.64%0.9990.989
All (published average)1481 / 148189.50%91.62%0.9870.943

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1481 (115V) and 1481 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 850 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 32.3 dB(A) at 115V and 32.2 dB(A) at 230V · loudest point 34.6 dB(A)
Efficiency 89.91% / 92.64% · power factor 0.999 / 0.989 (115V / 230V)
0510152025303540Average noise (dB(A))10.07.90-<20 %fan off 43%/52%12.412.220-<40 %fan off 3%/3%12.613.140-<60 %fan off 0%/0%22.222.360-<80 %fan off 0%/0%33.833.880-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))10.07.90-<20 %off 43%/52%12.412.220-<40 %off 3%/3%12.613.140-<60 %off 0%/0%22.222.360-<80 %off 0%/0%33.833.880-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %10.0 (12.6)7.9 (10.5)43% / 52%
20-<40 %12.4 (12.6)12.2 (12.6)3% / 3%
40-<60 %12.6 (18.2)13.1 (19.8)0% / 0%
60-<80 %22.2 (31.1)22.3 (30.3)0% / 0%
80-100 %33.8 (34.6)33.8 (34.6)0% / 0%
70-100 % (High-Load)32.3 (34.6)32.2 (34.6)0% / 0%
All (published average)27.5 (34.6)27.5 (34.6)6% / 7%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1481 (115V) and 1481 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 850 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 32.5 °C207 RPM · <6.0 dB(A) · 40.1 °C<6.0 in both
20%0 RPM · <6.0 dB(A) · 34.7 °C800 RPM · 12.6 dB(A) · 40.6 °Cfan starts (<6.0 → 12.6)
50%804 RPM · 12.6 dB(A) · 30.9 °C924 RPM · 17.0 dB(A) · 42.8 °C+4.4 dB(A)
100%1655 RPM · 34.4 dB(A) · 30.8 °C2138 RPM · 42.3 dB(A) · 45.4 °C+7.9 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 32.4 °C345 RPM · 7.5 dB(A) · 40.4 °Cfan starts (<6.0 → 7.5)
20%0 RPM · <6.0 dB(A) · 32.9 °C801 RPM · 12.6 dB(A) · 40.7 °Cfan starts (<6.0 → 12.6)
50%1134 RPM · 23.8 dB(A) · 30.8 °C930 RPM · 17.0 dB(A) · 42.5 °C-6.8 dB(A)
100%1592 RPM · 34.0 dB(A) · 30.0 °C2144 RPM · 42.8 dB(A) · 45.7 °C+8.8 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Cooler Master MWE Gold 850 V4

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus