| Average Efficiency (>1450 load combinations) | 91.625% |
| Average Noise Output (>1450 Load Combinations) | 27.55dBA |
| Average PF (>1450 Load Combinations) | 0.943 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 70.158% |
| Standby Power Consumption | 0.1658W |
| 12V Ripple (Full Load) | 35.11mV |
| 5V Ripple (Full Load) | 25.15mV |
| 3.3V Ripple (Full Load) | 21.97mV |
| 5VSB Ripple (Full Load) | 20.68mV |
| 12V Load Regulation | 0.83% |
| 5V Load Regulation | 0.12% |
| 3.3V Load Regulation | 0.15% |
| 5VSB Load Regulation | 3.76% |
| Inrush Current | 65.590A |
| 12V Transient Response (200%) | 11.41V |
| 5V Transient Response (200%) | 4.963V |
| 3.3V Transient Response (200%) | 3.234V |
| 5VSB Transient Response (200%) | 4.817V |
| Hold-Up Time & PWR_OK Signal | 18.40ms |
| AC Loss to PWR_OK Hold Up Time | 16.00ms |
| PWR_OK Inactive to DC Loss Delay | 2.40ms |
| PSU Timings: T1 (20% / 100%) | 116.0ms | 118.0ms |
| PSU Timings: T3 (20% / 100%) | 118.0ms | 118.0ms |
| 12V OCP (30.7°C / 41.9°C) | 81.300A (114.83%), 11.992V — shut down | 81.600A (115.25%), 11.986V — shut down |
| 5V OCP (30.7°C / 41.9°C) | 24.000A (120.00%), 5.209V — shut down | 24.000A (120.00%), 5.221V — shut down |
| 3.3V OCP (30.7°C / 41.9°C) | 24.000A (120.00%), 3.443V — shut down | 23.900A (119.50%), 3.451V — shut down |
| 5VSB OCP (30.7°C / 41.9°C) | 4.300A (143.33%), 4.880V — shut down | 4.300A (143.33%), 4.888V — shut down |
| OPP (27.31°C / 43.02°C) | 128.57% | 128.59% |