| Average Efficiency (>1450 load combinations) | 91.296% |
| Average Noise Output (>1450 Load Combinations) | 25.96dBA |
| Average PF (>1450 Load Combinations) | 0.936 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 68.368% |
| Standby Power Consumption | 0.1502W |
| 12V Ripple (Full Load) | 31.45mV |
| 5V Ripple (Full Load) | 20.40mV |
| 3.3V Ripple (Full Load) | 23.91mV |
| 5VSB Ripple (Full Load) | 21.96mV |
| 12V Load Regulation | 0.69% |
| 5V Load Regulation | 0.12% |
| 3.3V Load Regulation | 0.24% |
| 5VSB Load Regulation | 3.56% |
| Inrush Current | 60.160A |
| 12V Transient Response (200%) | 11.48V |
| 5V Transient Response (200%) | 4.947V |
| 3.3V Transient Response (200%) | 3.245V |
| 5VSB Transient Response (200%) | 4.931V |
| Hold-Up Time & PWR_OK Signal | 23.20ms |
| AC Loss to PWR_OK Hold Up Time | 19.00ms |
| PWR_OK Inactive to DC Loss Delay | 4.20ms |
| PSU Timings: T1 (20% / 100%) | 108.0ms | 111.0ms |
| PSU Timings: T3 (20% / 100%) | 120.0ms | 119.0ms |
| 12V OCP (29.2°C / 42.9°C) | 70.900A (113.44%), 11.989V — shut down | 70.900A (113.44%), 11.986V — shut down |
| 5V OCP (29.2°C / 42.9°C) | 24.100A (120.50%), 5.147V — shut down | 24.200A (121.00%), 5.166V — shut down |
| 3.3V OCP (29.2°C / 42.9°C) | 23.800A (119.00%), 3.439V — shut down | 23.800A (119.00%), 3.450V — shut down |
| 5VSB OCP (29.2°C / 42.9°C) | 4.300A (143.33%), 4.869V — shut down | 4.300A (143.33%), 4.865V — shut down |
| OPP (28.49°C / 42.43°C) | 129.18% | 129.17% |