| Average Efficiency (>1450 load combinations) | 92.860% |
| Average Noise Output (>1450 Load Combinations) | 12.22dBA |
| Average PF (>1450 Load Combinations) | 0.962 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 74.565% |
| Standby Power Consumption | 0.1141W |
| 12V Ripple (Full Load) | 29.82mV |
| 5V Ripple (Full Load) | 13.52mV |
| 3.3V Ripple (Full Load) | 15.16mV |
| 5VSB Ripple (Full Load) | 18.29mV |
| 12V Load Regulation | 0.47% |
| 5V Load Regulation | 0.65% |
| 3.3V Load Regulation | 1.21% |
| 5VSB Load Regulation | 4.08% |
| Inrush Current | 84.550A |
| 12V Transient Response (200%) | 11.27V |
| 5V Transient Response (200%) | 4.981V |
| 3.3V Transient Response (200%) | 3.181V |
| 5VSB Transient Response (200%) | 5.007V |
| Hold-Up Time & PWR_OK Signal | 17.90ms |
| AC Loss to PWR_OK Hold Up Time | 14.70ms |
| PWR_OK Inactive to DC Loss Delay | 3.20ms |
| PSU Timings: T1 (20% / 100%) | 76.0ms | 46.0ms |
| PSU Timings: T3 (20% / 100%) | 127.0ms | 125.0ms |
| 12V OCP (30.9°C / 41.8°C) | 119.830A (143.85%), 12.078V — shut down | 119.830A (143.85%), 12.082V — shut down |
| 5V OCP (30.9°C / 41.8°C) | 23.000A (115.00%), 5.073V — shut down | 21.700A (108.50%), 5.072V — shut down |
| 3.3V OCP (30.9°C / 41.8°C) | 27.300A (136.50%), 3.334V — shut down | 27.100A (135.50%), 3.336V — shut down |
| 5VSB OCP (30.9°C / 41.8°C) | 3.600A (120.00%), 4.952V — shut down | 3.600A (120.00%), 4.951V — shut down |
| OPP (29.47°C / 43.35°C) | 143.53% | 143.53% |