| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load range | Points | Efficiency 115V | Efficiency 230V | PF 115V | PF 230V |
|---|---|---|---|---|---|
| 0-<20 % | 228 / 228 | 85.46% | 86.50% | 0.972 | 0.882 |
| 20-<40 % | 331 / 331 | 90.99% | 92.35% | 0.988 | 0.956 |
| 40-<60 % | 327 / 327 | 91.64% | 93.35% | 0.991 | 0.975 |
| 60-<80 % | 333 / 333 | 91.15% | 93.26% | 0.993 | 0.983 |
| 80-100 % | 334 / 334 | 90.22% | 92.77% | 0.995 | 0.987 |
| 70-100 % (High-Load) | 505 / 505 | 90.47% | 92.91% | 0.995 | 0.986 |
| All (published average) | 1553 / 1553 | 90.18% | 91.99% | 0.989 | 0.961 |
Informational. Not part of the ETA or LAMBDA rating.
| Load range | Noise 115V avg (loudest) | Noise 230V avg (loudest) | Fan off 115V / 230V |
|---|---|---|---|
| 0-<20 % | <6.0 (<6.0) | <6.0 (<6.0) | 100% / 100% |
| 20-<40 % | <6.0 (<6.0) | <6.0 (<6.0) | 100% / 100% |
| 40-<60 % | 12.1 (23.5) | 13.7 (23.5) | 91% / 86% |
| 60-<80 % | 20.6 (23.5) | 20.6 (23.5) | 42% / 44% |
| 80-100 % | 24.4 (26.3) | 24.4 (26.3) | 3% / 4% |
| 70-100 % (High-Load) | 23.8 (26.3) | 23.7 (26.3) | 10% / 11% |
| All (published average) | 19.5 (26.3) | 19.5 (26.3) | 65% / 64% |
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 36.0 °C | 0 RPM · <6.0 dB(A) · 50.2 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 40.8 °C | 0 RPM · <6.0 dB(A) · 48.2 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 41.2 °C | 0 RPM · <6.0 dB(A) · 65.4 °C | fan off in both |
| 100% | 884 RPM · 25.3 dB(A) · 30.8 °C | 1343 RPM · 34.0 dB(A) · 45.5 °C | +8.7 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 41.5 °C | 0 RPM · <6.0 dB(A) · 47.2 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 42.4 °C | 0 RPM · <6.0 dB(A) · 46.5 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 45.3 °C | 0 RPM · <6.0 dB(A) · 50.8 °C | fan off in both |
| 100% | 945 RPM · 26.6 dB(A) · 30.5 °C | 1347 RPM · 34.0 dB(A) · 45.6 °C | +7.4 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.