CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Cougar GR X2 750
Serial Number-
Lab IDCG75003464
Certification ID263464
  • Test Result Report ID: 26PS3464A
  • Certificate Issue Date: Oct 11, 2026
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

84858687888990919293Average efficiency (%)85.3289.9790.8890.0889.0586.6791.4992.7092.4491.880-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
84858687888990919293Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0.9590.9890.9940.9960.9960.8100.9420.9710.9750.9750-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78115V230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %215 / 21585.32%86.67%0.9590.810
20-<40 %333 / 33389.97%91.49%0.9890.942
40-<60 %331 / 33190.88%92.70%0.9940.971
60-<80 %332 / 33290.08%92.44%0.9960.975
80-100 %341 / 34189.05%91.88%0.9960.975
70-100 % (High-Load)504 / 50489.30%92.01%0.9960.975
All (published average)1552 / 155289.34%91.37%0.9890.944

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1552 (115V) and 1552 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 22.8 dB(A) at 115V and 21.7 dB(A) at 230V · loudest point 30.3 dB(A)
Efficiency 89.30% / 92.01% · power factor 0.996 / 0.975 (115V / 230V)
051015202530Average noise (dB(A))6.66.60-<20 %fan off 0%/0%6.66.620-<40 %fan off 0%/0%6.66.740-<60 %fan off 0%/0%13.814.960-<80 %fan off 0%/0%24.222.980-100 %fan off 0%/0%115V230V
051015202530Average noise (dB(A))6.66.60-<20 %off 0%/0%6.66.620-<40 %off 0%/0%6.66.740-<60 %off 0%/0%13.814.960-<80 %off 0%/0%24.222.980-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %6.6 (6.6)6.6 (6.6)0% / 0%
20-<40 %6.6 (6.6)6.6 (6.6)0% / 0%
40-<60 %6.6 (10.9)6.7 (13.5)0% / 0%
60-<80 %13.8 (22.9)14.9 (22.9)0% / 0%
80-100 %24.2 (30.3)22.9 (27.4)0% / 0%
70-100 % (High-Load)22.8 (30.3)21.7 (27.4)0% / 0%
All (published average)18.2 (30.3)17.2 (27.4)0% / 0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1552 (115V) and 1552 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%498 RPM · 6.6 dB(A) · 30.1 °C530 RPM · 8.9 dB(A) · 40.1 °C+2.3 dB(A)
20%505 RPM · 7.5 dB(A) · 30.2 °C539 RPM · 11.1 dB(A) · 40.6 °C+3.6 dB(A)
50%513 RPM · 7.5 dB(A) · 30.5 °C551 RPM · 10.9 dB(A) · 42.2 °C+3.4 dB(A)
100%1092 RPM · 27.0 dB(A) · 30.0 °C1574 RPM · 39.7 dB(A) · 45.2 °C+12.7 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%516 RPM · 7.5 dB(A) · 30.9 °C526 RPM · 7.5 dB(A) · 40.1 °C+0.0 dB(A)
20%512 RPM · 7.5 dB(A) · 30.1 °C536 RPM · 8.9 dB(A) · 40.3 °C+1.4 dB(A)
50%511 RPM · 7.5 dB(A) · 30.8 °C549 RPM · 11.1 dB(A) · 42.1 °C+3.6 dB(A)
100%1067 RPM · 26.3 dB(A) · 30.4 °C1615 RPM · 39.4 dB(A) · 45.4 °C+13.1 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Cougar GR X2 750

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus