CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Super Flower Leadex 2500W ATX3+
Serial NumberS2609199012
Lab IDSF25003472
Certification ID263472
  • Test Result Report ID: 26PS3472A
  • Certificate Issue Date: Nov 3, 2026
230V
Scheme: ETA-EMI PSU
230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary 230V

Hold-Up Time & PWR_OK Signal

Vampire Power

Tables 230V

Graphs 230V

Efficiency Graph

230V

Efficiency and power factor by load range

878889909192939495Average efficiency (%)88.8894.6194.8794.2193.340-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87230V
878889909192939495Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0.8170.9320.9720.9820.9860-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78230V
Load rangePointsEfficiency
230V
PF
230V
0-<20 %30088.88%0.817
20-<40 %32194.61%0.932
40-<60 %32694.87%0.972
60-<80 %32094.21%0.982
80-100 %32993.34%0.986
70-100 % (High-Load)49093.55%0.985
All (published average)159693.25%0.940

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1596 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 2500 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

230V

Noise by load range

High-Load Index (70-100 % load)
Noise 45.4 dB(A) at 230V · loudest point 47.9 dB(A)
Efficiency 93.55% · power factor 0.985 (230V)
0510152025303540455055Average noise (dB(A))12.00-<20 %fan off 0%12.020-<40 %fan off 0%23.740-<60 %fan off 0%40.560-<80 %fan off 0%46.280-100 %fan off 0%230V
01020304050Average noise (dB(A))12.00-<20 %off 0%12.020-<40 %off 0%23.740-<60 %off 0%40.560-<80 %off 0%46.280-100 %off 0%230V
Load rangeNoise 230V
avg (loudest)
Fan off
230V
0-<20 %12.0 (12.0)0%
20-<40 %12.0 (12.0)0%
40-<60 %23.7 (31.3)0%
60-<80 %40.5 (44.3)0%
80-100 %46.2 (47.9)0%
70-100 % (High-Load)45.4 (47.9)0%
All (published average)40.4 (47.9)0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1596 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 2500 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%475 RPM · 11.5 dB(A) · 30.9 °C485 RPM · 11.5 dB(A) · 40.3 °C+0.0 dB(A)
20%477 RPM · 11.5 dB(A) · 30.1 °C486 RPM · 11.5 dB(A) · 41.0 °C+0.0 dB(A)
50%481 RPM · 11.5 dB(A) · 30.9 °C1235 RPM · 34.9 dB(A) · 42.2 °C+23.4 dB(A)
100%2081 RPM · 47.8 dB(A) · 30.9 °C2353 RPM · 50.4 dB(A) · 45.2 °C+2.6 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC) 230V

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests 230V

Light Load Tests 230V

Ripple Measurements 230V

Super Flower Leadex 2500W ATX3+

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure. THETA rates cooler performance on AMD AM5 and Intel LGA1851 outside ISO 17065 and accreditation scope
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus