CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Super Flower Leadex 2500W ATX3+
序号S2609199012
Lab IDSF25003472
Certification ID263472
  • Test Result Report ID: 26PS3472A
  • Certificate Issue Date: Nov 3, 2026
230V
Scheme: ETA-EMI PSU
230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

线材与接头(Non-accredited measurements)

Protection Features(Manufacturer)

电源规范

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary 230V

保持时间 & PG信号

待机电源

Tables 230V

Graphs 230V

转换效率图表

230V

Efficiency and power factor by load range

878889909192939495Average efficiency (%)88.8894.6194.8794.2193.340-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87230V
878889909192939495Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0.8170.9320.9720.9820.9860-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78230V
Load rangePointsEfficiency
230V
PF
230V
0-<20 %30088.88%0.817
20-<40 %32194.61%0.932
40-<60 %32694.87%0.972
60-<80 %32094.21%0.982
80-100 %32993.34%0.986
70-100 % (High-Load)49093.55%0.985
All (published average)159693.25%0.940

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1596 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 2500 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

噪音值图表

230V

Noise by load range

High-Load Index (70-100 % load)
Noise 45.4 dB(A) at 230V · loudest point 47.9 dB(A)
Efficiency 93.55% · power factor 0.985 (230V)
0510152025303540455055Average noise (dB(A))12.00-<20 %fan off 0%12.020-<40 %fan off 0%23.740-<60 %fan off 0%40.560-<80 %fan off 0%46.280-100 %fan off 0%230V
01020304050Average noise (dB(A))12.00-<20 %off 0%12.020-<40 %off 0%23.740-<60 %off 0%40.560-<80 %off 0%46.280-100 %off 0%230V
Load rangeNoise 230V
avg (loudest)
Fan off
230V
0-<20 %12.0 (12.0)0%
20-<40 %12.0 (12.0)0%
40-<60 %23.7 (31.3)0%
60-<80 %40.5 (44.3)0%
80-100 %46.2 (47.9)0%
70-100 % (High-Load)45.4 (47.9)0%
All (published average)40.4 (47.9)0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1596 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 2500 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%475 RPM · 11.5 dB(A) · 30.9 °C485 RPM · 11.5 dB(A) · 40.3 °C+0.0 dB(A)
20%477 RPM · 11.5 dB(A) · 30.1 °C486 RPM · 11.5 dB(A) · 41.0 °C+0.0 dB(A)
50%481 RPM · 11.5 dB(A) · 30.9 °C1235 RPM · 34.9 dB(A) · 42.2 °C+23.4 dB(A)
100%2081 RPM · 47.8 dB(A) · 30.9 °C2353 RPM · 50.4 dB(A) · 45.2 °C+2.6 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

高环温电源转换效率

5Vsb转换效率

输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V

Protection Features

Supplementary Tests (For Reference)

10-110%负载测试 230V

20-80瓦负载测试 230V

纹波测量 230V

Super Flower Leadex 2500W ATX3+

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
本测试报告中包含的所有数据和图表均可在以下条件下由任何人使用:使用过程需提及测试结果由Cybenetics提供。
在任何情况下都应提供原始测试结果文档的网站链接
Cybenetics 提供自愿性认证计划:电源方面有 ETA(效率)、LAMBDA(噪声)与 SAFE(安全与正确运行);散热产品方面有 DELTA(机箱隔音)与 PHI(风扇风量与静压)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus