| 230V | |
| Scheme: ETA-EMI PSU | ![]() |
| 230V | |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load range | Points | Efficiency 230V | PF 230V |
|---|---|---|---|
| 0-<20 % | 293 | 90.04% | 0.807 |
| 20-<40 % | 310 | 94.85% | 0.946 |
| 40-<60 % | 310 | 94.72% | 0.978 |
| 60-<80 % | 310 | 93.84% | 0.985 |
| 80-100 % | 312 | 92.77% | 0.989 |
| 70-100 % (High-Load) | 467 | 93.03% | 0.988 |
| All (published average) | 1535 | 93.28% | 0.942 |
Informational. Not part of the ETA or LAMBDA rating.
| Load range | Noise 230V avg (loudest) | Fan off 230V |
|---|---|---|
| 0-<20 % | 13.2 (13.2) | 0% |
| 20-<40 % | 14.2 (18.7) | 0% |
| 40-<60 % | 32.7 (39.1) | 0% |
| 60-<80 % | 43.5 (47.2) | 0% |
| 80-100 % | 49.7 (52.3) | 0% |
| 70-100 % (High-Load) | 48.6 (52.3) | 0% |
| All (published average) | 43.8 (52.3) | 0% |
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 532 RPM · 13.2 dB(A) · 30.3 °C | 549 RPM · 13.2 dB(A) · 40.5 °C | +0.0 dB(A) |
| 20% | 538 RPM · 13.2 dB(A) · 30.5 °C | 557 RPM · 13.2 dB(A) · 40.8 °C | +0.0 dB(A) |
| 50% | 545 RPM · 13.2 dB(A) · 30.9 °C | 1443 RPM · 39.7 dB(A) · 43.4 °C | +26.5 dB(A) |
| 100% | 2156 RPM · 48.5 dB(A) · 31.0 °C | 3033 RPM · 55.9 dB(A) · 45.8 °C | +7.4 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.