CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Super Flower Leadex 3000W ATX3+
Serial NumberS2609199014
Lab IDSF30003473
Certification ID263473
  • Test Result Report ID: 26PS3473A
  • Certificate Issue Date: Nov 3, 2026
230V
Scheme: ETA-EMI PSU
230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary 230V

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables 230V

Graphs 230V

Efficiency Graph

230V

Efficiency and power factor by load range

89909192939495Average efficiency (%)90.0494.8594.7293.8492.770-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 89230V
89909192939495Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 89230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0.8070.9460.9780.9850.9890-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78230V
Load rangePointsEfficiency
230V
PF
230V
0-<20 %29390.04%0.807
20-<40 %31094.85%0.946
40-<60 %31094.72%0.978
60-<80 %31093.84%0.985
80-100 %31292.77%0.989
70-100 % (High-Load)46793.03%0.988
All (published average)153593.28%0.942

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1535 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 3000 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

230V

Noise by load range

High-Load Index (70-100 % load)
Noise 48.6 dB(A) at 230V · loudest point 52.3 dB(A)
Efficiency 93.03% · power factor 0.988 (230V)
0510152025303540455055Average noise (dB(A))13.20-<20 %fan off 0%14.220-<40 %fan off 0%32.740-<60 %fan off 0%43.560-<80 %fan off 0%49.780-100 %fan off 0%230V
01020304050Average noise (dB(A))13.20-<20 %off 0%14.220-<40 %off 0%32.740-<60 %off 0%43.560-<80 %off 0%49.780-100 %off 0%230V
Load rangeNoise 230V
avg (loudest)
Fan off
230V
0-<20 %13.2 (13.2)0%
20-<40 %14.2 (18.7)0%
40-<60 %32.7 (39.1)0%
60-<80 %43.5 (47.2)0%
80-100 %49.7 (52.3)0%
70-100 % (High-Load)48.6 (52.3)0%
All (published average)43.8 (52.3)0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1535 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 3000 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%532 RPM · 13.2 dB(A) · 30.3 °C549 RPM · 13.2 dB(A) · 40.5 °C+0.0 dB(A)
20%538 RPM · 13.2 dB(A) · 30.5 °C557 RPM · 13.2 dB(A) · 40.8 °C+0.0 dB(A)
50%545 RPM · 13.2 dB(A) · 30.9 °C1443 RPM · 39.7 dB(A) · 43.4 °C+26.5 dB(A)
100%2156 RPM · 48.5 dB(A) · 31.0 °C3033 RPM · 55.9 dB(A) · 45.8 °C+7.4 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC) 230V

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests 230V

Light Load Tests 230V

Ripple Measurements 230V

Super Flower Leadex 3000W ATX3+

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern