CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Thermaltake Dockpower FI 850W
Serial NumberPSDCP0850FNFAGE2YFCY00002
Lab IDTT85003487
Certification ID263487
  • Test Result Report ID: 26PS3487A
  • Certificate Issue Date: Nov 9, 2026
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

85868788899091929394Average efficiency (%)86.1491.0891.2290.1889.0487.7192.6793.1692.5791.900-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
85868788899091929394Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
0.740.760.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0.9560.9850.9930.9950.9960.7790.9360.9680.9780.9820-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.74115V230V
0.740.760.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.74115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %228 / 22886.14%87.71%0.9560.779
20-<40 %331 / 33191.08%92.67%0.9850.936
40-<60 %328 / 32791.22%93.16%0.9930.968
60-<80 %332 / 33390.18%92.57%0.9950.978
80-100 %334 / 33489.04%91.90%0.9960.982
70-100 % (High-Load)499 / 49889.33%92.08%0.9960.981
All (published average)1553 / 155389.75%91.86%0.9870.939

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1553 (115V) and 1553 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 850 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 34.3 dB(A) at 115V and 33.4 dB(A) at 230V · loudest point 41.3 dB(A)
Efficiency 89.33% / 92.08% · power factor 0.996 / 0.981 (115V / 230V)
051015202530354045Average noise (dB(A))5.05.00-<20 %fan off 0%/100%5.05.020-<40 %fan off 0%/100%11.413.440-<60 %fan off 0%/56%21.320.060-<80 %fan off 0%/0%35.935.180-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))5.05.00-<20 %off 0%/100%5.05.020-<40 %off 0%/100%11.413.440-<60 %off 0%/56%21.320.060-<80 %off 0%/0%35.935.180-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %5.0 (5.0)5.0 (5.0)0% / 100%
20-<40 %5.0 (5.0)5.0 (5.0)0% / 100%
40-<60 %11.4 (16.6)13.4 (16.6)0% / 56%
60-<80 %21.3 (33.8)20.0 (33.8)0% / 0%
80-100 %35.9 (41.3)35.1 (41.3)0% / 0%
70-100 % (High-Load)34.3 (41.3)33.4 (41.3)0% / 0%
All (published average)29.4 (41.3)28.5 (41.3)0% / 48%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1553 (115V) and 1553 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 850 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 35.4 °C0 RPM · <6.0 dB(A) · 44.3 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 36.6 °C0 RPM · <6.0 dB(A) · 45.6 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 38.2 °C0 RPM · <6.0 dB(A) · 64.0 °Cfan off in both
100%1747 RPM · 43.9 dB(A) · 30.5 °C1888 RPM · 45.7 dB(A) · 45.5 °C+1.8 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%321 RPM · <6.0 dB(A) · 30.5 °C281 RPM · <6.0 dB(A) · 40.3 °Cfan off in both
20%322 RPM · <6.0 dB(A) · 30.7 °C281 RPM · <6.0 dB(A) · 40.5 °Cfan off in both
50%325 RPM · <6.0 dB(A) · 30.5 °C614 RPM · 17.1 dB(A) · 42.5 °Cfan starts (<6.0 → 17.1)
100%1584 RPM · 41.0 dB(A) · 30.8 °C1897 RPM · 46.2 dB(A) · 45.3 °C+5.2 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Thermaltake Dockpower FI 850W

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus