This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.212
58.564%
0.036
5.098V
0.362
115.11V
2
0.087A
0.444
68.519%
0.063
5.097V
0.648
115.11V
3
0.542A
2.758
77.515%
0.272
5.087V
3.558
115.11V
4
1.002A
5.085
76.260%
0.381
5.074V
6.668
115.11V
5
1.502A
7.606
76.251%
0.438
5.065V
9.975
115.11V
6
2.501A
12.610
74.002%
0.496
5.042V
17.040
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.212
54.780%
0.012
5.098V
0.387
230.31V
2
0.087A
0.445
65.154%
0.020
5.097V
0.683
230.31V
3
0.542A
2.757
76.118%
0.102
5.086V
3.622
230.30V
4
1.002A
5.086
76.666%
0.174
5.075V
6.634
230.30V
5
1.502A
7.606
76.836%
0.235
5.065V
9.899
230.31V
6
2.501A
12.606
77.007%
0.320
5.040V
16.370
230.31V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.383A
1.965A
1.949A
0.986A
74.802
85.576%
758
21.2
40.10°C
0.968
12.141V
5.088V
3.384V
5.065V
87.410
46.01°C
115.13V
2
9.799A
2.947A
2.934A
1.186A
149.730
89.721%
758
21.2
40.87°C
0.986
12.132V
5.077V
3.372V
5.053V
166.884
47.23°C
115.14V
3
15.570A
3.458A
3.446A
1.385A
224.871
91.014%
755
21.3
41.17°C
0.989
12.124V
5.069V
3.363V
5.041V
247.072
48.03°C
115.13V
4
21.337A
3.955A
3.933A
1.590A
299.728
91.199%
753
21.4
41.65°C
0.990
12.116V
5.062V
3.354V
5.030V
328.653
49.03°C
115.13V
5
26.777A
4.951A
4.935A
1.790A
374.685
90.988%
753
21.4
42.20°C
0.990
12.107V
5.054V
3.342V
5.017V
411.797
50.47°C
115.12V
6
32.218A
5.949A
5.941A
1.996A
449.538
90.484%
750
21.4
42.61°C
0.989
12.098V
5.042V
3.330V
5.003V
496.813
52.52°C
115.12V
7
37.676A
6.958A
6.962A
2.200A
524.596
89.144%
935
25.5
43.16°C
0.988
12.090V
5.033V
3.317V
4.991V
588.482
54.89°C
115.19V
8
43.135A
7.967A
7.984A
2.410A
599.516
88.351%
1165
31.7
43.68°C
0.989
12.081V
5.023V
3.305V
4.978V
678.562
55.66°C
115.13V
9
49.035A
8.477A
8.526A
2.411A
674.541
87.564%
1380
36.6
44.89°C
0.991
12.072V
5.015V
3.295V
4.971V
770.340
57.42°C
115.21V
10
54.892A
8.995A
9.039A
2.516A
749.369
86.771%
1467
39.9
46.27°C
0.992
12.063V
5.006V
3.285V
4.962V
863.616
59.21°C
115.17V
11
58.432A
9.011A
9.058A
2.520A
824.240
85.736%
1465
39.9
47.06°C
0.993
12.613V
5.000V
3.279V
4.953V
961.372
60.50°C
115.18V
CL1
0.100A
14.028A
14.006A
0.004A
118.532
83.662%
763
20.8
45.12°C
0.983
12.123V
5.048V
3.319V
5.064V
141.679
55.65°C
115.24V
CL2
61.934A
1.003A
1.002A
1.002A
760.950
87.276%
1470
39.9
46.02°C
0.992
12.070V
5.037V
3.331V
5.006V
871.887
58.07°C
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.387A
1.963A
1.952A
0.986A
74.817
83.238%
758
21.2
40.08°C
0.834
12.135V
5.087V
3.383V
5.062V
89.883
45.58°C
230.24V
2
9.798A
2.949A
2.934A
1.186A
149.753
89.558%
755
21.3
40.82°C
0.923
12.135V
5.077V
3.372V
5.050V
167.214
46.86°C
230.23V
3
15.571A
3.456A
3.445A
1.386A
224.892
91.472%
755
21.3
41.11°C
0.951
12.126V
5.068V
3.361V
5.039V
245.859
47.67°C
230.24V
4
21.338A
3.952A
3.935A
1.591A
299.768
92.099%
753
21.4
41.81°C
0.963
12.118V
5.061V
3.353V
5.028V
325.486
48.85°C
230.24V
5
26.780A
4.948A
4.937A
1.792A
374.762
92.213%
753
21.4
42.14°C
0.970
12.109V
5.053V
3.341V
5.015V
406.411
49.30°C
230.24V
6
32.223A
5.943A
5.943A
1.998A
449.619
91.963%
768
20.5
42.97°C
0.974
12.099V
5.043V
3.330V
5.001V
488.915
50.58°C
230.24V
7
37.674A
6.959A
6.965A
2.201A
524.648
91.735%
760
21.2
43.17°C
0.977
12.092V
5.031V
3.316V
4.992V
571.914
51.39°C
230.25V
8
43.138A
7.965A
7.987A
2.410A
599.596
91.193%
1110
31.3
43.96°C
0.978
12.082V
5.023V
3.305V
4.978V
657.502
52.48°C
230.24V
9
49.035A
8.476A
8.527A
2.411A
674.623
90.806%
1330
36.3
44.56°C
0.979
12.074V
5.014V
3.294V
4.972V
742.926
53.24°C
230.24V
10
54.892A
8.995A
9.038A
2.516A
749.484
90.330%
1467
39.9
45.55°C
0.980
12.065V
5.007V
3.285V
4.962V
829.715
54.96°C
230.25V
11
61.140A
9.010A
9.057A
2.521A
824.392
89.895%
1467
39.9
46.61°C
0.983
12.057V
5.000V
3.278V
4.954V
917.060
56.62°C
230.25V
CL1
0.098A
14.025A
14.004A
0.005A
118.548
83.311%
766
20.5
43.19°C
0.906
12.121V
5.051V
3.320V
5.066V
142.295
51.95°C
230.25V
CL2
61.944A
1.002A
1.003A
1.002A
761.193
91.010%
1470
39.9
45.38°C
0.980
12.072V
5.037V
3.331V
5.007V
836.383
54.70°C
230.25V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.492A
0.469A
0.196A
19.667
60.070%
760
21.2
0.868
12.141V
5.098V
3.396V
5.088V
32.740
115.14V
2
2.424A
0.981A
0.971A
0.391A
39.720
79.045%
758
21.2
0.930
12.146V
5.095V
3.392V
5.081V
50.250
115.14V
3
3.659A
1.467A
1.475A
0.591A
59.893
83.860%
758
21.2
0.959
12.143V
5.090V
3.387V
5.075V
71.420
115.13V
4
4.875A
1.966A
1.948A
0.786A
79.758
86.422%
758
21.2
0.971
12.140V
5.087V
3.383V
5.069V
92.289
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.204A
0.489A
0.469A
0.196A
19.703
50.722%
758
21.2
0.592
12.144V
5.097V
3.395V
5.086V
38.845
230.24V
2
2.430A
0.980A
0.972A
0.391A
39.776
72.494%
758
21.2
0.707
12.141V
5.093V
3.392V
5.079V
54.868
230.24V
3
3.662A
1.466A
1.474A
0.591A
59.897
81.362%
755
21.3
0.788
12.138V
5.088V
3.386V
5.073V
73.618
230.24V
4
4.878A
1.965A
1.949A
0.786A
79.757
84.399%
758
21.2
0.844
12.134V
5.085V
3.382V
5.068V
94.500
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.0 mV
31.6 mV
13.1 mV
22.6 mV
Pass
20% Load
23.5 mV
34.8 mV
15.3 mV
24.1 mV
Pass
30% Load
25.4 mV
35.8 mV
14.3 mV
23.5 mV
Pass
40% Load
28.3 mV
34.4 mV
14.1 mV
23.9 mV
Pass
50% Load
31.7 mV
34.1 mV
13.0 mV
23.9 mV
Pass
60% Load
37.5 mV
35.4 mV
14.2 mV
34.3 mV
Pass
70% Load
36.6 mV
37.9 mV
22.9 mV
25.6 mV
Pass
80% Load
38.2 mV
39.7 mV
27.1 mV
23.6 mV
Pass
90% Load
41.2 mV
36.6 mV
25.2 mV
25.0 mV
Pass
100% Load
46.8 mV
42.3 mV
23.2 mV
29.5 mV
Pass
110% Load
48.8 mV
41.6 mV
22.1 mV
28.9 mV
Pass
Crossload 1
32.8 mV
32.6 mV
17.3 mV
63.3 mV
Fail
Crossload 2
37.1 mV
39.5 mV
19.2 mV
27.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.6 mV
30.2 mV
14.3 mV
22.4 mV
Pass
20% Load
28.9 mV
34.3 mV
14.3 mV
22.5 mV
Pass
30% Load
32.0 mV
45.1 mV
18.7 mV
24.5 mV
Pass
40% Load
31.4 mV
36.6 mV
15.6 mV
27.3 mV
Pass
50% Load
34.1 mV
39.7 mV
17.8 mV
25.8 mV
Pass
60% Load
34.6 mV
37.7 mV
15.1 mV
29.1 mV
Pass
70% Load
38.5 mV
40.7 mV
22.8 mV
27.5 mV
Pass
80% Load
40.7 mV
42.0 mV
26.1 mV
25.3 mV
Pass
90% Load
43.8 mV
41.0 mV
26.8 mV
26.0 mV
Pass
100% Load
46.2 mV
39.6 mV
25.9 mV
28.7 mV
Pass
110% Load
48.7 mV
39.3 mV
22.5 mV
27.5 mV
Pass
Crossload 1
41.3 mV
34.7 mV
16.6 mV
71.6 mV
Fail
Crossload 2
37.7 mV
37.4 mV
20.1 mV
23.7 mV
Pass
The results above are not used in the certification process