This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
噪音值图表
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC)
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.044A
0.225
67.365%
0.032
5.106V
0.334
115.39V
2
0.089A
0.455
73.151%
0.060
5.105V
0.622
115.39V
3
0.540A
2.752
77.850%
0.268
5.095V
3.535
115.38V
4
1.000A
5.086
77.732%
0.372
5.084V
6.543
115.39V
5
1.500A
7.612
78.160%
0.426
5.073V
9.739
115.38V
6
3.001A
15.093
76.316%
0.493
5.030V
19.777
115.37V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.044A
0.225
57.990%
0.013
5.106V
0.388
230.97V
2
0.089A
0.455
66.423%
0.023
5.105V
0.685
230.97V
3
0.540A
2.752
76.064%
0.113
5.094V
3.618
230.96V
4
1.000A
5.085
77.291%
0.189
5.084V
6.579
230.96V
5
1.500A
7.610
77.416%
0.251
5.072V
9.830
230.96V
6
3.001A
15.117
77.802%
0.355
5.038V
19.430
230.96V
Protection Features
Supplementary Tests (For Reference)
10-110%负载测试
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
5.222A
1.996A
1.987A
0.985A
84.992
86.748%
621
11.6
41.65°C
0.973
12.137V
5.010V
3.327V
5.078V
97.976
47.59°C
115.27V
2
11.485A
2.997A
2.979A
1.184A
170.301
90.194%
565
10.7
38.83°C
0.988
12.136V
5.009V
3.325V
5.069V
188.816
47.93°C
115.17V
3
18.076A
3.497A
3.490A
1.384A
255.483
91.014%
550
10.4
39.01°C
0.990
12.136V
5.008V
3.323V
5.059V
280.706
48.41°C
115.15V
4
24.667A
3.997A
3.973A
1.585A
340.575
91.022%
550
10.4
39.57°C
0.991
12.136V
5.007V
3.322V
5.050V
374.169
49.23°C
115.03V
5
30.861A
4.998A
4.968A
1.786A
425.082
90.655%
560
10.5
40.75°C
0.990
12.137V
5.006V
3.321V
5.041V
468.903
50.75°C
114.91V
6
37.117A
5.997A
5.965A
1.988A
510.384
90.095%
880
20.6
41.79°C
0.991
12.139V
5.005V
3.320V
5.031V
566.497
52.22°C
114.88V
7
43.348A
6.997A
6.961A
2.192A
595.278
89.427%
1333
31.4
42.33°C
0.991
12.138V
5.004V
3.319V
5.020V
665.660
52.93°C
114.75V
8
49.587A
7.998A
7.962A
2.395A
680.212
88.693%
1984
41.5
42.93°C
0.992
12.136V
5.003V
3.317V
5.011V
766.925
53.79°C
114.72V
9
56.248A
8.499A
8.474A
2.398A
765.241
87.942%
2310
45.1
44.02°C
0.992
12.136V
5.002V
3.316V
5.006V
870.166
55.12°C
114.58V
10
62.643A
9.000A
8.958A
3.009A
849.956
87.009%
2320
45.2
45.40°C
0.993
12.136V
5.002V
3.315V
4.987V
976.857
56.83°C
114.43V
11
69.683A
9.000A
8.962A
3.012A
935.525
85.851%
2225
44.7
47.19°C
0.993
12.138V
5.001V
3.314V
4.981V
1089.714
58.87°C
114.39V
CL1
0.159A
12.001A
12.000A
0.001A
101.985
85.242%
560
10.5
43.42°C
0.983
12.145V
5.008V
3.329V
5.092V
119.642
53.02°C
115.24V
CL2
70.008A
1.002A
1.001A
1.001A
863.063
87.262%
2320
45.2
45.75°C
0.993
12.137V
5.004V
3.315V
5.039V
989.045
56.15°C
114.43V
The results above are not used in the certification process
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
5.208A
1.996A
1.982A
0.985A
84.840
87.431%
675
13.8
39.70°C
0.826
12.144V
5.010V
3.327V
5.076V
97.036
46.04°C
230.88V
2
11.400A
2.996A
2.975A
1.185A
169.340
91.393%
560
10.5
40.03°C
0.929
12.144V
5.008V
3.325V
5.065V
185.287
47.41°C
230.83V
3
17.987A
3.496A
3.461A
1.385A
254.440
92.476%
560
10.5
40.78°C
0.959
12.144V
5.007V
3.323V
5.054V
275.143
48.65°C
230.77V
4
24.573A
3.997A
3.972A
1.586A
339.642
92.686%
560
10.5
41.33°C
0.971
12.145V
5.006V
3.322V
5.043V
366.444
49.83°C
230.70V
5
30.828A
4.995A
4.968A
1.788A
424.965
92.577%
590
12.8
42.09°C
0.977
12.147V
5.005V
3.321V
5.033V
459.039
50.87°C
230.64V
6
37.016A
5.997A
5.964A
1.992A
509.484
92.211%
1015
23.6
42.48°C
0.981
12.148V
5.004V
3.320V
5.022V
552.520
51.80°C
230.68V
7
43.281A
6.998A
6.961A
2.196A
594.801
91.780%
1650
36.9
43.67°C
0.983
12.146V
5.003V
3.318V
5.010V
648.071
53.47°C
230.62V
8
49.545A
8.001A
7.961A
2.401A
680.139
91.283%
2130
44.4
44.38°C
0.985
12.145V
5.001V
3.316V
4.999V
745.089
54.58°C
230.55V
9
56.200A
8.501A
8.446A
2.404A
765.065
90.888%
2330
45.4
45.22°C
0.986
12.145V
5.001V
3.315V
4.993V
841.767
55.82°C
230.32V
10
62.586A
9.003A
8.960A
3.017A
849.881
90.180%
2340
45.4
46.39°C
0.987
12.146V
5.000V
3.314V
4.973V
942.424
57.53°C
230.42V
11
69.566A
9.003A
8.964A
3.021A
934.658
89.523%
2340
45.4
47.16°C
0.988
12.146V
4.999V
3.313V
4.967V
1044.048
58.98°C
230.47V
CL1
0.144A
12.001A
11.998A
0.000A
101.768
86.140%
560
10.5
44.36°C
0.868
12.149V
5.008V
3.327V
5.088V
118.143
54.52°C
230.95V
CL2
70.004A
1.002A
0.998A
1.000A
863.621
90.526%
2340
45.4
45.89°C
0.987
12.146V
5.003V
3.317V
5.029V
954.007
57.07°C
230.42V
The results above are not used in the certification process
20-80瓦负载测试
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.273A
0.500A
0.482A
0.197A
20.562
69.035%
0
<6.0
0.810
12.133V
5.014V
3.329V
5.101V
29.785
115.36V
2
2.456A
1.001A
0.995A
0.393A
40.123
79.750%
0
<6.0
0.915
12.133V
5.009V
3.325V
5.095V
50.311
115.34V
3
3.709A
1.499A
1.507A
0.590A
60.535
84.325%
0
<6.0
0.954
12.135V
5.010V
3.327V
5.089V
71.788
115.31V
4
4.895A
1.999A
1.986A
0.788A
80.033
86.626%
0
<6.0
0.971
12.136V
5.010V
3.327V
5.083V
92.389
115.29V
The results above are not used in the certification process
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.190A
0.499A
0.479A
0.196A
19.548
69.710%
0
<6.0
0.492
12.143V
5.015V
3.331V
5.100V
28.042
230.92V
2
2.441A
0.999A
0.991A
0.393A
39.947
81.002%
0
<6.0
0.640
12.144V
5.010V
3.328V
5.094V
49.316
230.91V
3
3.623A
1.496A
1.473A
0.590A
59.396
85.279%
0
<6.0
0.744
12.144V
5.010V
3.328V
5.088V
69.649
230.89V
4
4.880A
1.995A
1.983A
0.787A
79.854
87.528%
0
<6.0
0.812
12.144V
5.010V
3.327V
5.081V
91.233
230.89V
The results above are not used in the certification process
纹波测量
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.0 mV
5.2 mV
3.6 mV
2.8 mV
Pass
20% Load
10.4 mV
6.1 mV
4.5 mV
3.5 mV
Pass
30% Load
13.3 mV
6.6 mV
5.0 mV
4.3 mV
Pass
40% Load
15.2 mV
7.7 mV
5.7 mV
4.7 mV
Pass
50% Load
15.7 mV
9.2 mV
6.7 mV
4.7 mV
Pass
60% Load
15.1 mV
9.9 mV
7.3 mV
5.8 mV
Pass
70% Load
16.5 mV
10.2 mV
7.8 mV
5.8 mV
Pass
80% Load
18.3 mV
10.4 mV
8.7 mV
8.7 mV
Pass
90% Load
21.2 mV
11.2 mV
9.0 mV
9.1 mV
Pass
100% Load
24.2 mV
12.3 mV
9.5 mV
9.8 mV
Pass
110% Load
26.9 mV
12.7 mV
9.7 mV
9.9 mV
Pass
Crossload 1
8.4 mV
10.6 mV
7.8 mV
3.3 mV
Pass
Crossload 2
24.0 mV
7.9 mV
5.8 mV
7.2 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.60mV
5.30mV
4.00mV
2.90mV
Pass
20% Load
9.80mV
5.90mV
4.50mV
3.40mV
Pass
30% Load
12.30mV
6.50mV
4.90mV
3.90mV
Pass
40% Load
14.50mV
7.80mV
5.70mV
3.80mV
Pass
50% Load
14.60mV
9.30mV
6.80mV
3.90mV
Pass
60% Load
14.40mV
9.70mV
7.30mV
4.90mV
Pass
70% Load
15.70mV
10.10mV
7.90mV
4.30mV
Pass
80% Load
18.40mV
10.00mV
9.00mV
7.10mV
Pass
90% Load
20.80mV
10.40mV
9.20mV
7.50mV
Pass
100% Load
23.10mV
11.50mV
9.60mV
7.50mV
Pass
110% Load
25.80mV
12.20mV
10.10mV
8.00mV
Pass
Crossload1
8.00mV
10.30mV
8.20mV
3.30mV
Pass
Crossload2
23.70mV
7.90mV
6.10mV
5.20mV
Pass
The results above are not used in the certification process