Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (560mm)
1
1
18-22AWG
No
4+4 pin EPS12V (750mm)
1
1
16AWG
No
4+4 pin EPS12V (550mm)
1
1
16AWG
No
6+2 pin PCIe (550mm)
4
4
16AWG
No
SATA (610mm+150mm+150mm+150mm)
3
12
18AWG
No
4 pin Molex (600mm+150mm+150mm)
1
3
18AWG
No
FDD Adapter (+105mm)
1
1
22AWG
No
AC Power Cord (1400mm) - C13 coupler
1
1
16AWG
-
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
22
2
70.9
3
0.3
Watts
120
850
15
3.6
Total Max. Power (W)
850
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
90.245%
Average Noise Output (>1450 Load Combinations)
23.61dBA
Average PF (>1450 Load Combinations)
0.992
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0866W
Non-Accredited
12V Ripple (Full Load)
34.12mV
5V Ripple (Full Load)
25.62mV
3.3V Ripple (Full Load)
19.85mV
5VSB Ripple (Full Load)
25.48mV
12V Load Regulation
1.26%
5V Load Regulation
1.63%
3.3V Load Regulation
2.46%
5VSB Load Regulation
2.88%
Inrush Current
96.359A
Accredited
Average Efficiency (>1450 load combinations)
91.973%
Average Noise Output (>1450 Load Combinations)
23.94dBA
Average PF (>1450 Load Combinations)
0.963
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1571W
Non-Accredited
12V Ripple (Full Load)
33.34mV
5V Ripple (Full Load)
25.40mV
3.3V Ripple (Full Load)
20.20mV
5VSB Ripple (Full Load)
25.34mV
12V Load Regulation
1.24%
5V Load Regulation
1.63%
3.3V Load Regulation
2.46%
5VSB Load Regulation
2.88%
Inrush Current
63.703A
Hold-Up Time & PWR_OK Signal
9.70ms
AC Loss to PWR_OK Hold Up Time
11.10ms
PWR_OK Inactive to DC Loss Delay
-1.40ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
9.7
AC Loss to PWR_OK Hold Up Time (ms)
11.1
PWR_OK Inactive to DC Loss Delay (ms)
-1.4
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
66.189%
0.028
5.115V
0.349
115.38V
2
0.090A
0.461
72.828%
0.050
5.113V
0.633
115.38V
3
0.550A
2.802
80.080%
0.217
5.094V
3.499
115.37V
4
1.000A
5.079
80.966%
0.293
5.078V
6.273
115.37V
5
1.500A
7.591
80.884%
0.337
5.060V
9.385
115.37V
6
3.000A
15.000
79.085%
0.394
5.000V
18.967
115.36V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
56.757%
0.012
5.115V
0.407
230.93V
2
0.090A
0.461
64.838%
0.020
5.112V
0.711
230.94V
3
0.550A
2.800
76.004%
0.098
5.090V
3.684
230.93V
4
1.000A
5.075
78.804%
0.158
5.074V
6.440
230.92V
5
1.500A
7.584
79.364%
0.211
5.055V
9.556
230.92V
6
3.000A
14.996
79.034%
0.301
4.998V
18.974
230.92V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.156A
1.960A
1.960A
0.986A
84.775
89.574%
735
15.3
45.53°C
0.968
12.256V
5.097V
3.364V
5.070V
94.642
39.17°C
115.27V
2
11.303A
2.948A
2.950A
1.186A
169.245
91.875%
660
13.4
39.43°C
0.986
12.240V
5.088V
3.355V
5.059V
184.213
46.29°C
115.16V
3
17.861A
3.445A
3.435A
1.387A
254.344
92.351%
1245
29.9
39.90°C
0.994
12.225V
5.080V
3.346V
5.046V
275.409
47.36°C
115.05V
4
24.438A
3.941A
3.953A
1.590A
339.550
92.240%
1255
30.7
40.83°C
0.995
12.209V
5.072V
3.338V
5.033V
368.115
48.59°C
115.03V
5
30.705A
4.938A
4.952A
1.792A
424.872
91.749%
1335
30.5
40.74°C
0.996
12.193V
5.063V
3.329V
5.022V
463.081
49.24°C
114.91V
6
36.924A
5.937A
5.962A
1.996A
509.395
91.218%
1415
33.0
41.41°C
0.997
12.176V
5.054V
3.321V
5.011V
558.437
50.27°C
114.89V
7
43.225A
6.937A
6.973A
2.201A
594.713
90.710%
1480
35.9
42.67°C
0.997
12.160V
5.045V
3.312V
5.000V
655.621
51.89°C
114.77V
8
49.552A
7.945A
7.991A
2.406A
680.067
89.986%
1545
35.7
43.43°C
0.998
12.142V
5.036V
3.303V
4.988V
755.750
53.19°C
114.64V
9
56.288A
8.454A
8.496A
2.409A
764.996
89.200%
1565
36.0
44.59°C
0.998
12.125V
5.028V
3.295V
4.982V
857.618
54.54°C
114.61V
10
62.777A
8.968A
9.040A
3.030A
849.824
88.180%
1535
35.0
45.40°C
0.998
12.108V
5.019V
3.286V
4.952V
963.738
55.93°C
114.47V
11
69.877A
8.982A
9.063A
3.035A
934.593
86.983%
1545
35.7
46.72°C
0.996
12.091V
5.011V
3.277V
4.943V
1074.454
57.84°C
114.43V
CL1
0.138A
14.003A
13.998A
0.000A
119.704
85.192%
675
14.4
42.63°C
0.984
12.244V
5.074V
3.355V
5.152V
140.511
51.77°C
115.24V
CL2
70.834A
1.001A
0.999A
1.000A
871.056
88.518%
1545
35.7
44.61°C
0.998
12.109V
5.033V
3.293V
4.999V
984.045
54.87°C
114.46V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.171A
1.963A
1.964A
0.987A
84.984
89.840%
735
15.3
46.31°C
0.820
12.255V
5.096V
3.364V
5.069V
94.595
40.12°C
230.89V
2
11.321A
2.950A
2.952A
1.187A
169.469
92.672%
660
13.4
40.72°C
0.930
12.239V
5.087V
3.354V
5.058V
182.870
47.80°C
230.84V
3
17.880A
3.447A
3.438A
1.388A
254.558
93.545%
1245
29.9
41.17°C
0.958
12.223V
5.079V
3.345V
5.045V
272.125
48.80°C
230.77V
4
24.454A
3.946A
3.956A
1.590A
339.723
93.740%
1280
29.8
41.77°C
0.976
12.207V
5.071V
3.337V
5.032V
362.411
49.54°C
230.79V
5
30.717A
4.939A
4.957A
1.793A
425.007
93.666%
1345
31.0
42.12°C
0.981
12.192V
5.062V
3.329V
5.021V
453.748
50.54°C
230.75V
6
36.936A
5.938A
5.962A
1.997A
509.500
93.309%
1375
31.7
42.76°C
0.986
12.175V
5.053V
3.320V
5.010V
546.035
51.55°C
230.69V
7
43.235A
6.939A
6.976A
2.201A
594.793
92.903%
1475
35.8
43.22°C
0.990
12.159V
5.044V
3.311V
4.998V
640.227
52.45°C
230.62V
8
49.557A
7.945A
7.994A
2.407A
680.132
92.419%
1515
36.0
43.76°C
0.993
12.142V
5.035V
3.303V
4.987V
735.924
53.23°C
230.56V
9
56.291A
8.457A
8.498A
2.410A
765.039
91.840%
1560
35.9
44.43°C
0.995
12.125V
5.027V
3.294V
4.981V
833.017
54.56°C
230.50V
10
62.780A
8.969A
9.043A
3.031A
849.859
91.112%
1525
35.5
45.29°C
0.996
12.108V
5.018V
3.285V
4.951V
932.762
55.85°C
230.52V
11
69.875A
8.984A
9.062A
3.036A
934.630
90.275%
1550
35.7
46.73°C
0.997
12.092V
5.010V
3.276V
4.942V
1035.314
57.83°C
230.46V
CL1
0.141A
14.003A
13.999A
0.000A
119.744
85.608%
675
14.4
43.49°C
0.896
12.243V
5.074V
3.355V
5.153V
139.874
52.46°C
230.94V
CL2
70.840A
1.001A
1.001A
1.000A
871.060
91.482%
1500
36.3
45.12°C
0.996
12.108V
5.032V
3.292V
4.998V
952.162
55.79°C
230.53V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.172A
0.489A
0.472A
0.196A
19.460
70.825%
730
15.3
0.815
12.264V
5.104V
3.372V
5.099V
27.476
115.35V
2
2.415A
0.980A
0.977A
0.393A
39.905
82.580%
735
15.3
0.918
12.262V
5.102V
3.369V
5.093V
48.323
115.32V
3
3.587A
1.470A
1.452A
0.590A
59.362
86.460%
735
15.3
0.947
12.260V
5.100V
3.367V
5.085V
68.658
115.30V
4
4.828A
1.960A
1.960A
0.788A
79.764
89.033%
735
15.3
0.967
12.257V
5.097V
3.365V
5.078V
89.589
115.27V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.185A
0.491A
0.473A
0.196A
19.632
71.894%
730
15.3
0.472
12.263V
5.104V
3.372V
5.099V
27.307
230.92V
2
2.428A
0.980A
0.981A
0.393A
40.076
82.838%
730
15.3
0.634
12.261V
5.102V
3.369V
5.092V
48.379
230.92V
3
3.600A
1.472A
1.454A
0.590A
59.535
87.025%
735
15.3
0.736
12.259V
5.099V
3.367V
5.085V
68.411
230.91V
4
4.830A
1.960A
1.961A
0.788A
79.770
89.380%
730
15.3
0.808
12.254V
5.096V
3.363V
5.076V
89.248
230.99V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.3 mV
9.7 mV
5.9 mV
5.6 mV
Pass
20% Load
6.5 mV
10.9 mV
6.4 mV
6.7 mV
Pass
30% Load
8.5 mV
13.8 mV
7.9 mV
8.9 mV
Pass
40% Load
10.3 mV
16.9 mV
10.0 mV
12.9 mV
Pass
50% Load
12.4 mV
21.3 mV
12.7 mV
15.7 mV
Pass
60% Load
14.3 mV
21.9 mV
16.0 mV
15.8 mV
Pass
70% Load
18.2 mV
22.2 mV
14.8 mV
16.2 mV
Pass
80% Load
22.8 mV
22.0 mV
16.2 mV
18.2 mV
Pass
90% Load
28.9 mV
23.4 mV
19.1 mV
22.1 mV
Pass
100% Load
34.1 mV
25.6 mV
19.9 mV
25.5 mV
Pass
110% Load
42.0 mV
29.8 mV
23.8 mV
35.3 mV
Pass
Crossload 1
6.7 mV
12.3 mV
12.2 mV
6.5 mV
Pass
Crossload 2
34.2 mV
24.6 mV
16.4 mV
25.2 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.6 mV
9.4 mV
5.4 mV
5.7 mV
Pass
20% Load
6.3 mV
11.2 mV
6.3 mV
6.8 mV
Pass
30% Load
7.9 mV
13.3 mV
7.4 mV
9.2 mV
Pass
40% Load
9.7 mV
16.4 mV
9.9 mV
12.9 mV
Pass
50% Load
12.0 mV
20.2 mV
12.3 mV
16.1 mV
Pass
60% Load
13.9 mV
21.8 mV
15.6 mV
16.3 mV
Pass
70% Load
17.4 mV
21.6 mV
15.2 mV
16.7 mV
Pass
80% Load
22.3 mV
21.6 mV
16.7 mV
18.7 mV
Pass
90% Load
27.8 mV
23.1 mV
18.8 mV
22.1 mV
Pass
100% Load
33.3 mV
25.4 mV
20.2 mV
25.3 mV
Pass
110% Load
46.5 mV
30.8 mV
27.8 mV
36.6 mV
Pass
Crossload 1
6.9 mV
12.6 mV
12.0 mV
6.8 mV
Pass
Crossload 2
32.6 mV
23.8 mV
16.6 mV
25.3 mV
Pass
The results above are not used in the certification process
SilverStone Strider Platinum 850W
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern