140mm Hydro Dynamic Bearing Fan (TT-1425 (A1425L12S))
Semi-Passive Operation
✓ (selectable)
Cybenetics Testing Information
Lab ID
483
Date of receipt
Sep 10, 2018
Testing Date
Sep 23, 2018
Report Issued Date
Sep 26, 2018
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
18AWG
No
4+4 pin EPS12V (660mm)
1
1
18AWG
No
6+2 pin PCIe (500mm+155mm)
2
4
18AWG
No
SATA (510mm+155mm+155mm)
3
9
18AWG
No
4-pin Molex (500mm+150mm+150mm+150mm)
1
4
18AWG
No
RGB Cable (580mm+80mm)
1
1
26AWG
No
FDD Adapter (+160mm)
1
1
22AWG
No
AC Power Cord (1400mm) - C13 coupler
1
1
18AWG
-
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
22
22
54.2
3
0.3
Watts
120
650
15
3.6
Total Max. Power (W)
650
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.838%
Average Noise Output (>1450 Load Combinations)
29.30dBA
Average PF (>1450 Load Combinations)
0.988
Efficiency With 10W (≤500W) or 2% (>500W) Load
62.497%
Standby Power Consumption
0.0901W
Non-Accredited
12V Ripple (Full Load)
18.65mV
5V Ripple (Full Load)
18.68mV
3.3V Ripple (Full Load)
17.14mV
5VSB Ripple (Full Load)
11.29mV
12V Load Regulation
1.13%
5V Load Regulation
2.18%
3.3V Load Regulation
3.93%
5VSB Load Regulation
4.78%
Inrush Current
32.625A
Accredited
Average Efficiency (>1450 load combinations)
90.410%
Average Noise Output (>1450 Load Combinations)
29.25dBA
Average PF (>1450 Load Combinations)
0.940
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1676W
Non-Accredited
12V Ripple (Full Load)
16.91mV
5V Ripple (Full Load)
18.27mV
3.3V Ripple (Full Load)
17.00mV
5VSB Ripple (Full Load)
11.52mV
12V Load Regulation
1.07%
5V Load Regulation
2.16%
3.3V Load Regulation
3.87%
5VSB Load Regulation
4.77%
Inrush Current
67.251A
Hold-Up Time & PWR_OK Signal
16.40ms
AC Loss to PWR_OK Hold Up Time
15.00ms
PWR_OK Inactive to DC Loss Delay
1.40ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
16.4
AC Loss to PWR_OK Hold Up Time (ms)
15
PWR_OK Inactive to DC Loss Delay (ms)
1.4
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
66.667%
0.043
5.104V
0.345
115.05V
2
0.090A
0.460
72.785%
0.077
5.102V
0.632
115.05V
3
0.550A
2.795
79.246%
0.252
5.080V
3.527
115.06V
4
1.000A
5.060
79.585%
0.299
5.060V
6.358
115.05V
5
1.500A
7.556
79.545%
0.324
5.037V
9.499
115.05V
6
3.000A
14.887
76.777%
0.360
4.962V
19.390
115.04V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
58.524%
0.017
5.104V
0.393
230.20V
2
0.090A
0.460
65.341%
0.029
5.102V
0.704
230.02V
3
0.550A
2.794
75.087%
0.133
5.080V
3.721
230.20V
4
1.000A
5.060
77.655%
0.192
5.059V
6.516
230.20V
5
1.500A
7.555
77.774%
0.233
5.036V
9.714
230.18V
6
3.000A
14.895
76.739%
0.286
4.965V
19.410
230.20V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.560A
1.970A
1.968A
0.994A
64.889
85.816%
0
<6.0
48.34°C
0.946
12.160V
5.078V
3.351V
5.032V
75.614
40.47°C
115.06V
2
8.109A
2.961A
2.966A
1.197A
129.390
89.713%
687
13.7
40.88°C
0.977
12.145V
5.067V
3.338V
5.014V
144.226
49.23°C
115.06V
3
13.059A
3.462A
3.459A
1.402A
194.464
91.167%
585
9.6
41.09°C
0.985
12.134V
5.056V
3.325V
4.994V
213.306
50.02°C
115.06V
4
18.029A
3.966A
3.983A
1.609A
259.687
91.524%
580
9.5
41.71°C
0.994
12.118V
5.045V
3.314V
4.974V
283.738
51.23°C
115.05V
5
22.676A
4.969A
5.001A
1.817A
324.980
91.064%
575
9.5
42.30°C
0.994
12.104V
5.033V
3.299V
4.954V
356.870
52.44°C
115.05V
6
27.270A
5.976A
6.028A
2.027A
389.503
90.481%
830
19.4
42.53°C
0.994
12.090V
5.021V
3.285V
4.934V
430.481
53.45°C
115.05V
7
31.941A
6.990A
7.063A
2.239A
454.760
89.849%
1020
26.2
43.37°C
0.995
12.074V
5.008V
3.270V
4.914V
506.139
54.81°C
115.05V
8
36.617A
8.007A
8.111A
2.453A
520.081
89.129%
1150
30.0
43.57°C
0.996
12.062V
4.996V
3.255V
4.893V
583.514
55.46°C
115.04V
9
41.720A
8.530A
8.632A
2.457A
584.994
88.497%
1415
36.1
44.75°C
0.996
12.044V
4.985V
3.243V
4.885V
661.033
56.80°C
115.04V
10
46.549A
9.051A
9.196A
3.102A
649.842
87.655%
1430
36.3
45.63°C
0.997
12.033V
4.974V
3.229V
4.837V
741.364
58.22°C
115.04V
11
51.991A
9.066A
9.222A
3.108A
714.651
86.935%
1430
36.3
46.57°C
0.997
12.020V
4.966V
3.220V
4.827V
822.051
59.73°C
115.04V
CL1
0.142A
14.002A
13.999A
0.000A
118.128
82.280%
695
13.8
42.39°C
0.978
12.152V
5.033V
3.281V
5.092V
143.569
52.47°C
115.06V
CL2
54.172A
1.003A
0.999A
1.000A
665.100
88.437%
1430
36.3
45.34°C
0.997
12.033V
5.007V
3.275V
4.954V
752.060
58.34°C
115.04V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.557A
1.967A
1.968A
0.994A
64.854
86.629%
0
<6.0
46.76°C
0.790
12.163V
5.079V
3.352V
5.033V
74.864
40.25°C
230.03V
2
8.108A
2.961A
2.965A
1.197A
129.350
90.583%
687
13.7
40.75°C
0.884
12.143V
5.066V
3.337V
5.013V
142.797
47.78°C
230.21V
3
13.059A
3.461A
3.458A
1.402A
194.438
92.458%
585
9.6
41.34°C
0.911
12.133V
5.055V
3.325V
4.993V
210.299
48.89°C
230.03V
4
18.027A
3.964A
3.982A
1.609A
259.648
92.656%
580
9.5
41.65°C
0.916
12.118V
5.045V
3.314V
4.973V
280.227
49.80°C
230.20V
5
22.676A
4.968A
5.000A
1.817A
324.887
92.467%
575
9.5
42.31°C
0.955
12.100V
5.033V
3.300V
4.955V
351.356
50.94°C
230.21V
6
27.270A
5.979A
6.028A
2.027A
389.479
92.076%
830
19.4
42.55°C
0.972
12.089V
5.020V
3.284V
4.934V
422.997
51.67°C
230.20V
7
31.940A
6.991A
7.067A
2.240A
454.825
91.697%
1020
26.2
43.21°C
0.976
12.076V
5.008V
3.269V
4.913V
496.010
52.68°C
230.02V
8
36.617A
8.009A
8.113A
2.453A
520.126
91.168%
1150
30.0
43.63°C
0.983
12.063V
4.996V
3.254V
4.893V
570.514
53.67°C
230.02V
9
41.713A
8.528A
8.635A
2.458A
585.067
90.549%
1417
36.2
44.47°C
0.989
12.048V
4.985V
3.242V
4.883V
646.133
55.20°C
230.03V
10
46.554A
9.051A
9.200A
3.103A
649.898
89.922%
1430
36.3
45.78°C
0.991
12.033V
4.973V
3.228V
4.836V
722.733
57.16°C
230.19V
11
52.000A
9.067A
9.229A
3.109A
714.718
89.412%
1422
36.2
46.66°C
0.993
12.019V
4.965V
3.219V
4.826V
799.352
58.63°C
230.19V
CL1
0.144A
14.003A
14.000A
0.000A
118.147
82.901%
695
13.8
42.85°C
0.880
12.151V
5.032V
3.281V
5.092V
142.516
51.65°C
230.21V
CL2
54.178A
1.000A
1.001A
1.000A
665.109
90.773%
1425
36.3
45.35°C
0.992
12.032V
5.007V
3.275V
4.954V
732.720
57.27°C
230.19V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.186A
0.493A
0.475A
0.197A
19.568
68.093%
0
<6.0
0.870
12.192V
5.089V
3.366V
5.080V
28.737
115.06V
2
2.439A
0.983A
0.981A
0.395A
39.982
81.302%
0
<6.0
0.916
12.171V
5.085V
3.361V
5.067V
49.177
115.05V
3
3.625A
1.476A
1.461A
0.594A
59.505
85.335%
0
<6.0
0.943
12.165V
5.082V
3.356V
5.055V
69.731
115.05V
4
4.876A
1.970A
1.969A
0.794A
79.905
87.469%
0
<6.0
0.957
12.162V
5.078V
3.350V
5.042V
91.352
115.06V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.184A
0.490A
0.476A
0.197A
19.542
68.939%
0
<6.0
0.547
12.199V
5.092V
3.367V
5.083V
28.347
230.21V
2
2.434A
0.983A
0.982A
0.395A
39.936
82.281%
0
<6.0
0.696
12.174V
5.087V
3.361V
5.070V
48.536
230.20V
3
3.622A
1.475A
1.458A
0.594A
59.453
85.936%
0
<6.0
0.776
12.165V
5.082V
3.356V
5.056V
69.183
230.21V
4
4.871A
1.970A
1.969A
0.794A
79.822
88.120%
0
<6.0
0.825
12.158V
5.077V
3.350V
5.042V
90.583
230.21V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.0 mV
9.6 mV
9.3 mV
16.0 mV
Pass
20% Load
23.7 mV
10.5 mV
10.3 mV
17.6 mV
Pass
30% Load
26.9 mV
11.5 mV
11.1 mV
19.7 mV
Pass
40% Load
27.9 mV
13.2 mV
15.8 mV
19.7 mV
Pass
50% Load
31.0 mV
15.0 mV
17.7 mV
20.1 mV
Pass
60% Load
37.7 mV
17.3 mV
34.0 mV
21.8 mV
Pass
70% Load
36.5 mV
19.7 mV
16.9 mV
32.1 mV
Pass
80% Load
39.2 mV
21.4 mV
17.9 mV
27.9 mV
Pass
90% Load
41.0 mV
23.9 mV
28.2 mV
30.1 mV
Pass
100% Load
45.1 mV
29.9 mV
33.9 mV
28.4 mV
Pass
110% Load
47.2 mV
31.7 mV
39.7 mV
30.2 mV
Pass
Crossload 1
36.2 mV
17.4 mV
11.9 mV
15.1 mV
Pass
Crossload 2
37.4 mV
26.8 mV
38.9 mV
33.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
28.0 mV
6.3 mV
6.8 mV
4.1 mV
Pass
20% Load
21.4 mV
7.3 mV
9.0 mV
4.7 mV
Pass
30% Load
11.3 mV
9.3 mV
10.6 mV
7.2 mV
Pass
40% Load
11.5 mV
9.3 mV
10.2 mV
6.2 mV
Pass
50% Load
12.0 mV
11.1 mV
11.2 mV
6.9 mV
Pass
60% Load
12.3 mV
15.1 mV
14.1 mV
10.2 mV
Pass
70% Load
13.2 mV
13.5 mV
13.4 mV
8.4 mV
Pass
80% Load
14.1 mV
15.1 mV
15.2 mV
9.2 mV
Pass
90% Load
15.6 mV
16.4 mV
16.6 mV
10.3 mV
Pass
100% Load
16.9 mV
18.3 mV
17.0 mV
11.5 mV
Pass
110% Load
19.0 mV
19.6 mV
17.8 mV
12.0 mV
Pass
Crossload 1
21.7 mV
13.4 mV
14.6 mV
6.9 mV
Pass
Crossload 2
17.6 mV
13.0 mV
12.1 mV
9.1 mV
Pass
The results above are not used in the certification process