This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228
66.279%
0.051
5.048V
0.344
115.06V
2
0.090A
0.455
71.429%
0.092
5.048V
0.637
115.06V
3
0.550A
2.774
85.066%
0.314
5.043V
3.261
115.07V
4
1.000A
5.038
84.772%
0.397
5.037V
5.943
115.06V
5
1.500A
7.548
83.597%
0.440
5.031V
9.029
115.06V
6
2.500A
12.550
83.628%
0.476
5.019V
15.007
115.06V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228
58.163%
0.170
5.034V
0.392
230.22V
2
0.090A
0.455
65.280%
0.031
5.048V
0.697
230.20V
3
0.550A
2.774
82.806%
0.137
5.042V
3.350
230.21V
4
1.000A
5.038
84.374%
0.215
5.037V
5.971
230.20V
5
1.500A
7.548
84.232%
0.276
5.031V
8.961
230.04V
6
2.500A
12.549
84.216%
0.344
5.019V
14.901
230.21V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.934A
1.986A
1.972A
0.994A
44.909
85.283%
0
<6.0
44.75°C
0.858
12.050V
5.037V
3.345V
5.034V
52.659
40.08°C
115.06V
2
4.852A
2.979A
2.961A
1.193A
89.359
89.723%
0
<6.0
45.84°C
0.932
12.048V
5.036V
3.344V
5.028V
99.594
40.77°C
115.06V
3
8.175A
3.477A
3.440A
1.394A
134.502
91.229%
0
<6.0
47.05°C
0.957
12.048V
5.035V
3.343V
5.023V
147.434
41.47°C
115.06V
4
11.497A
3.974A
3.948A
1.594A
179.719
91.795%
0
<6.0
48.93°C
0.971
12.048V
5.034V
3.343V
5.019V
195.783
42.17°C
115.06V
5
14.485A
4.969A
4.937A
1.796A
225.016
91.879%
1348
14.7
42.24°C
0.979
12.047V
5.034V
3.342V
5.012V
244.906
49.71°C
115.05V
6
17.405A
5.963A
5.924A
1.998A
269.521
91.408%
1479
17.8
42.84°C
0.983
12.049V
5.033V
3.341V
5.007V
294.856
51.57°C
115.05V
7
20.391A
6.958A
6.915A
2.200A
314.804
91.135%
1694
21.8
43.31°C
0.986
12.049V
5.032V
3.340V
5.002V
345.427
53.01°C
115.05V
8
23.380A
7.954A
7.907A
2.402A
360.101
90.778%
1902
24.6
43.80°C
0.988
12.048V
5.031V
3.339V
4.996V
396.683
54.06°C
115.05V
9
26.771A
8.451A
8.386A
2.404A
405.017
90.381%
2510
32.9
44.80°C
0.989
12.047V
5.030V
3.338V
4.994V
448.123
55.64°C
115.05V
10
30.093A
8.951A
8.901A
2.506A
449.720
89.925%
2979
37.5
45.62°C
0.990
12.046V
5.029V
3.337V
4.989V
500.103
57.34°C
115.04V
11
33.816A
8.951A
8.902A
2.507A
494.519
89.459%
3489
41.5
46.72°C
0.990
12.045V
5.028V
3.336V
4.987V
552.786
58.90°C
115.04V
CL1
0.139A
12.003A
11.999A
0.000A
102.248
87.187%
665
6.3
42.35°C
0.941
12.065V
5.034V
3.346V
5.035V
117.275
50.39°C
115.06V
CL2
37.509A
1.002A
1.002A
1.000A
465.118
90.573%
2948
37.6
45.36°C
0.990
12.043V
5.031V
3.337V
5.013V
513.526
57.26°C
115.04V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.932A
1.985A
1.971A
0.994A
44.874
85.132%
0
<6.0
44.60°C
0.685
12.050V
5.036V
3.345V
5.034V
52.711
40.21°C
230.20V
2
4.848A
2.980A
2.959A
1.193A
89.341
90.374%
0
<6.0
45.82°C
0.824
12.055V
5.035V
3.344V
5.028V
98.857
40.96°C
230.21V
3
8.170A
3.476A
3.438A
1.394A
134.455
92.145%
0
<6.0
46.70°C
0.887
12.051V
5.035V
3.343V
5.024V
145.917
41.56°C
230.20V
4
11.492A
3.974A
3.947A
1.594A
179.676
92.855%
0
<6.0
48.37°C
0.918
12.050V
5.034V
3.342V
5.019V
193.501
42.59°C
230.19V
5
14.484A
4.969A
4.938A
1.796A
224.968
93.440%
1363
15.0
42.98°C
0.943
12.045V
5.033V
3.341V
5.012V
240.763
49.18°C
230.19V
6
17.406A
5.962A
5.926A
1.998A
269.491
93.054%
1481
17.9
43.42°C
0.950
12.047V
5.032V
3.341V
5.006V
289.608
50.28°C
230.19V
7
20.392A
6.958A
6.916A
2.200A
314.790
92.943%
1698
21.7
43.86°C
0.960
12.048V
5.031V
3.340V
5.001V
338.690
51.65°C
230.19V
8
23.380A
7.955A
7.905A
2.403A
360.117
92.725%
1906
24.7
44.20°C
0.966
12.049V
5.030V
3.339V
4.995V
388.370
52.50°C
230.20V
9
26.772A
8.454A
8.390A
2.404A
405.044
92.524%
2343
30.5
44.90°C
0.970
12.047V
5.029V
3.338V
4.992V
437.772
54.08°C
230.20V
10
30.099A
8.951A
8.901A
2.506A
449.753
92.226%
2969
37.6
45.52°C
0.973
12.045V
5.028V
3.337V
4.989V
487.666
55.94°C
230.20V
11
33.821A
8.955A
8.903A
2.508A
494.571
91.911%
3483
41.5
46.57°C
0.976
12.044V
5.028V
3.336V
4.986V
538.100
57.42°C
230.20V
CL1
0.141A
12.003A
12.001A
0.000A
102.279
88.002%
760
6.6
42.60°C
0.850
12.065V
5.034V
3.346V
5.035V
116.224
49.25°C
230.20V
CL2
37.513A
1.002A
1.001A
1.000A
465.128
92.924%
2857
36.2
45.18°C
0.974
12.042V
5.031V
3.338V
5.013V
500.544
55.41°C
230.20V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.199A
0.496A
0.478A
0.198A
19.545
76.404%
0
<6.0
0.755
12.050V
5.039V
3.346V
5.045V
25.581
115.06V
2
2.466A
0.993A
0.987A
0.397A
40.019
85.432%
0
<6.0
0.846
12.049V
5.038V
3.346V
5.042V
46.843
115.06V
3
3.660A
1.488A
1.464A
0.596A
59.490
88.148%
0
<6.0
0.892
12.048V
5.037V
3.345V
5.038V
67.489
115.06V
4
4.918A
1.987A
1.973A
0.795A
79.862
89.690%
0
<6.0
0.925
12.048V
5.037V
3.345V
5.034V
89.042
115.06V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.198A
0.495A
0.479A
0.198A
19.534
75.975%
0
<6.0
0.502
12.052V
5.038V
3.347V
5.045V
25.711
230.20V
2
2.464A
0.993A
0.987A
0.397A
39.997
84.982%
0
<6.0
0.657
12.050V
5.037V
3.346V
5.042V
47.065
230.19V
3
3.657A
1.489A
1.465A
5.038A
59.462
88.207%
0
<6.0
0.745
12.048V
5.037V
3.345V
5.038V
67.412
230.19V
4
4.917A
1.984A
1.972A
0.795A
79.854
90.195%
0
<6.0
0.802
12.053V
5.036V
3.345V
5.034V
88.535
230.20V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.6 mV
6.5 mV
4.5 mV
8.4 mV
Pass
20% Load
8.4 mV
7.5 mV
5.4 mV
10.3 mV
Pass
30% Load
11.1 mV
7.3 mV
5.8 mV
9.9 mV
Pass
40% Load
12.4 mV
7.8 mV
5.9 mV
9.3 mV
Pass
50% Load
14.8 mV
8.3 mV
6.6 mV
9.4 mV
Pass
60% Load
16.7 mV
9.0 mV
7.4 mV
9.3 mV
Pass
70% Load
19.5 mV
9.7 mV
8.6 mV
10.9 mV
Pass
80% Load
19.3 mV
10.3 mV
11.7 mV
12.1 mV
Pass
90% Load
21.5 mV
10.9 mV
12.8 mV
13.0 mV
Pass
100% Load
23.3 mV
11.9 mV
14.4 mV
14.5 mV
Pass
110% Load
26.2 mV
11.9 mV
13.8 mV
15.6 mV
Pass
Crossload 1
10.0 mV
12.3 mV
11.1 mV
16.6 mV
Pass
Crossload 2
23.5 mV
8.1 mV
11.6 mV
16.6 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.1 mV
8.0 mV
4.9 mV
7.2 mV
Pass
20% Load
20.0 mV
7.7 mV
5.3 mV
9.7 mV
Pass
30% Load
15.8 mV
7.3 mV
5.6 mV
9.4 mV
Pass
40% Load
15.7 mV
8.1 mV
5.9 mV
9.2 mV
Pass
50% Load
15.2 mV
8.1 mV
6.6 mV
9.5 mV
Pass
60% Load
17.3 mV
8.9 mV
7.6 mV
10.2 mV
Pass
70% Load
19.2 mV
9.4 mV
8.5 mV
10.7 mV
Pass
80% Load
20.3 mV
10.4 mV
11.6 mV
12.4 mV
Pass
90% Load
22.0 mV
11.0 mV
12.6 mV
12.9 mV
Pass
100% Load
23.9 mV
12.3 mV
14.4 mV
14.4 mV
Pass
110% Load
26.0 mV
11.9 mV
14.9 mV
15.6 mV
Pass
Crossload 1
16.3 mV
12.2 mV
10.8 mV
15.8 mV
Pass
Crossload 2
24.2 mV
8.1 mV
10.8 mV
16.2 mV
Pass
The results above are not used in the certification process
Corsair SF450 Platinum
Top side
Power specifications table
ybenetics bietet die freiwilligen ETA- und Lambda-Zertifizierungsprogramme an, mit denen effiziente und leise Netzteile (PSU) beworben werden