Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (610mm)
1
1
16-20AWG
Yes
4+4 pin EPS12V (650mm)
2
2
18AWG
Yes
6+2 pin PCIe (670mm+100mm)
4
8
16-18AWG
Yes
SATA (460mm+110mm+110mm+110mm)
4
16
18AWG
No
4 pin Molex (550mm+100mm+100mm)
2
6
18AWG
No
FDD Adapter (110mm)
1
1
22AWG
No
AC Power Cord (1400mm)
1
1
14AWG
-
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
70
3
0.3
Watts
100
840
15
3.6
Total Max. Power (W)
850
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
92.543%
Average Noise Output (>1450 Load Combinations)
15.37dBA
Average PF (>1450 Load Combinations)
0.988
Efficiency With 10W (≤500W) or 2% (>500W) Load
75.879%
Standby Power Consumption
0.0477W
Non-Accredited
12V Ripple (Full Load)
10.79mV
5V Ripple (Full Load)
5.76mV
3.3V Ripple (Full Load)
11.80mV
5VSB Ripple (Full Load)
9.60mV
12V Load Regulation
0.25%
5V Load Regulation
0.42%
3.3V Load Regulation
0.38%
5VSB Load Regulation
1.17%
Inrush Current
44.445A
Accredited
Average Efficiency (>1450 load combinations)
94.077%
Average Noise Output (>1450 Load Combinations)
14.66dBA
Average PF (>1450 Load Combinations)
0.944
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0795W
Non-Accredited
12V Ripple (Full Load)
10.85mV
5V Ripple (Full Load)
5.93mV
3.3V Ripple (Full Load)
11.52mV
5VSB Ripple (Full Load)
10.64mV
12V Load Regulation
0.23%
5V Load Regulation
0.42%
3.3V Load Regulation
0.36%
5VSB Load Regulation
1.15%
Inrush Current
63.621A
Hold-Up Time & PWR_OK Signal
22.10ms
AC Loss to PWR_OK Hold Up Time
20.40ms
PWR_OK Inactive to DC Loss Delay
1.70ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
22.1
AC Loss to PWR_OK Hold Up Time (ms)
20.4
PWR_OK Inactive to DC Loss Delay (ms)
1.7
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.223
68.196%
0.000
4.957V
0.327
115.08V
2
0.090A
0.446
72.876%
0.058
4.956V
0.612
115.08V
3
0.550A
2.722
80.342%
0.250
4.948V
3.388
115.13V
4
1.000A
4.940
80.456%
0.345
4.939V
6.140
115.13V
5
1.500A
7.395
80.582%
0.401
4.929V
9.177
115.13V
6
3.001A
14.703
79.869%
0.474
4.900V
18.409
115.12V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.223
60.270%
0.011
4.957V
0.370
230.22V
2
0.090A
0.446
67.988%
0.019
4.956V
0.656
365.12V
3
0.550A
2.720
77.163%
0.097
4.946V
3.525
230.22V
4
1.000A
4.938
78.983%
0.160
4.937V
6.252
230.22V
5
1.500A
7.392
79.544%
0.217
4.927V
9.293
230.22V
6
3.000A
14.690
79.153%
0.326
4.896V
18.559
230.22V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.158A
1.977A
1.953A
0.992A
84.759
91.742%
0
<6.0
46.67°C
0.957
12.248V
5.056V
3.376V
5.044V
92.388
39.72°C
115.10V
2
11.302A
2.967A
2.932A
1.191A
169.272
93.792%
0
<6.0
47.61°C
0.983
12.244V
5.054V
3.374V
5.040V
180.476
40.29°C
115.11V
3
17.840A
3.466A
3.407A
1.391A
254.382
94.374%
0
<6.0
49.13°C
0.992
12.241V
5.051V
3.373V
5.035V
269.547
41.23°C
115.11V
4
24.390A
3.960A
3.912A
1.591A
339.654
93.904%
609
13.6
41.66°C
0.991
12.237V
5.050V
3.372V
5.031V
361.704
50.10°C
115.11V
5
30.609A
4.955A
4.893A
1.791A
424.971
93.528%
617
14.0
42.11°C
0.993
12.234V
5.047V
3.370V
5.027V
454.377
51.54°C
115.11V
6
36.766A
5.947A
5.877A
1.991A
509.488
93.116%
665
16.3
42.74°C
0.995
12.231V
5.045V
3.369V
5.023V
547.157
52.67°C
115.12V
7
42.992A
6.941A
6.857A
2.192A
594.807
92.497%
718
18.9
43.20°C
0.996
12.228V
5.043V
3.368V
5.020V
643.058
53.46°C
115.12V
8
49.224A
7.936A
7.841A
2.393A
680.174
91.940%
804
24.0
43.49°C
0.997
12.225V
5.041V
3.367V
5.016V
739.806
54.50°C
115.12V
9
55.856A
8.436A
8.319A
2.393A
765.116
91.388%
865
25.9
44.59°C
0.997
12.221V
5.039V
3.365V
5.014V
837.221
55.93°C
115.13V
10
62.220A
8.937A
8.827A
2.999A
849.915
90.836%
928
27.1
45.80°C
0.997
12.218V
5.037V
3.364V
5.002V
935.657
57.55°C
115.13V
11
69.177A
8.939A
8.830A
3.001A
934.705
90.202%
1141
33.7
46.60°C
0.998
12.215V
5.035V
3.363V
5.000V
1036.237
58.75°C
115.13V
CL1
0.147A
11.999A
12.000A
0.000A
102.847
89.010%
776
22.4
42.73°C
0.969
12.245V
5.052V
3.369V
5.076V
115.545
51.65°C
115.14V
CL2
70.013A
1.003A
0.998A
1.000A
868.794
91.108%
905
26.7
45.44°C
0.998
12.217V
5.040V
3.369V
5.028V
953.588
57.46°C
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.167A
1.978A
1.954A
0.992A
84.872
92.300%
0
<6.0
46.14°C
0.779
12.245V
5.056V
3.376V
5.044V
91.952
39.33°C
230.32V
2
11.307A
2.968A
2.933A
1.191A
169.319
94.647%
0
<6.0
47.58°C
0.899
12.242V
5.054V
3.374V
5.040V
178.895
40.15°C
230.32V
3
17.844A
3.464A
3.406A
1.390A
254.380
95.211%
0
<6.0
48.66°C
0.940
12.239V
5.052V
3.373V
5.035V
267.174
40.87°C
230.31V
4
24.384A
3.959A
3.912A
1.590A
339.546
95.360%
0
<6.0
49.46°C
0.960
12.236V
5.050V
3.372V
5.031V
356.068
41.42°C
230.29V
5
30.602A
4.951A
4.892A
1.790A
424.837
95.203%
618
14.0
41.83°C
0.970
12.233V
5.048V
3.371V
5.027V
446.244
50.37°C
230.28V
6
36.761A
5.944A
5.872A
1.991A
509.366
94.955%
631
14.7
42.63°C
0.976
12.230V
5.046V
3.369V
5.024V
536.430
51.62°C
230.28V
7
42.986A
6.938A
6.858A
2.191A
594.639
94.676%
695
17.5
42.80°C
0.981
12.226V
5.044V
3.368V
5.020V
628.077
52.45°C
230.29V
8
49.216A
7.934A
7.837A
2.393A
680.003
94.343%
777
22.4
43.36°C
0.985
12.224V
5.041V
3.367V
5.016V
720.775
53.47°C
230.28V
9
55.849A
8.433A
8.319A
2.393A
764.972
93.979%
852
25.1
44.52°C
0.986
12.220V
5.039V
3.366V
5.015V
813.982
55.05°C
230.29V
10
62.217A
8.935A
8.825A
2.999A
849.811
93.578%
921
27.0
45.55°C
0.988
12.217V
5.037V
3.365V
5.003V
908.135
56.56°C
230.29V
11
69.174A
8.937A
8.828A
3.000A
934.589
93.152%
1172
34.5
46.61°C
0.990
12.214V
5.035V
3.364V
5.001V
1003.300
57.87°C
230.30V
CL1
0.140A
11.997A
11.998A
0.000A
102.756
89.822%
729
19.8
42.15°C
0.829
12.243V
5.053V
3.369V
5.076V
114.399
50.88°C
230.29V
CL2
70.004A
1.000A
0.997A
1.000A
868.596
93.849%
891
26.1
45.29°C
0.989
12.216V
5.040V
3.369V
5.029V
925.522
56.39°C
230.30V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.170A
0.493A
0.471A
0.198A
19.421
77.771%
0
<6.0
0.778
12.249V
5.062V
3.380V
5.061V
24.972
115.09V
2
2.416A
0.988A
0.974A
0.396A
39.881
87.016%
0
<6.0
0.901
12.249V
5.058V
3.377V
5.054V
45.832
115.10V
3
3.588A
1.480A
1.449A
0.594A
59.328
89.580%
0
<6.0
0.936
12.249V
5.057V
3.377V
5.051V
66.229
115.10V
4
4.828A
1.977A
1.952A
0.793A
79.721
91.555%
0
<6.0
0.954
12.248V
5.056V
3.376V
5.048V
87.074
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.178A
0.491A
0.472A
0.198A
19.510
78.303%
0
<6.0
0.439
12.247V
5.062V
3.380V
5.061V
24.916
230.30V
2
2.422A
0.990A
0.976A
0.396A
39.965
86.780%
0
<6.0
0.612
12.246V
5.058V
3.377V
5.054V
46.053
230.30V
3
3.595A
1.483A
1.448A
0.594A
59.413
90.252%
0
<6.0
0.705
12.245V
5.058V
3.377V
5.051V
65.830
230.31V
4
4.838A
1.978A
1.952A
0.793A
79.837
92.007%
0
<6.0
0.766
12.245V
5.057V
3.376V
5.048V
86.773
230.30V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.7 mV
4.3 mV
8.6 mV
6.8 mV
Pass
20% Load
8.3 mV
4.6 mV
9.0 mV
7.1 mV
Pass
30% Load
9.2 mV
5.2 mV
9.6 mV
7.2 mV
Pass
40% Load
5.7 mV
5.8 mV
9.9 mV
8.0 mV
Pass
50% Load
5.6 mV
4.7 mV
9.7 mV
8.0 mV
Pass
60% Load
6.0 mV
5.1 mV
9.7 mV
8.5 mV
Pass
70% Load
6.7 mV
5.0 mV
10.3 mV
8.3 mV
Pass
80% Load
6.9 mV
5.1 mV
10.6 mV
8.9 mV
Pass
90% Load
6.8 mV
5.1 mV
10.4 mV
8.1 mV
Pass
100% Load
10.8 mV
5.8 mV
11.8 mV
9.6 mV
Pass
110% Load
10.9 mV
5.7 mV
12.5 mV
10.1 mV
Pass
Crossload 1
8.9 mV
5.1 mV
12.0 mV
7.8 mV
Pass
Crossload 2
10.9 mV
5.5 mV
10.7 mV
9.6 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.10mV
4.80mV
8.80mV
7.10mV
Pass
20% Load
8.80mV
4.70mV
8.90mV
7.00mV
Pass
30% Load
10.00mV
4.90mV
8.90mV
7.40mV
Pass
40% Load
5.70mV
5.70mV
10.40mV
8.40mV
Pass
50% Load
5.40mV
5.20mV
9.50mV
7.90mV
Pass
60% Load
6.20mV
5.00mV
10.40mV
9.50mV
Pass
70% Load
6.70mV
5.30mV
10.00mV
8.90mV
Pass
80% Load
7.10mV
5.00mV
10.80mV
9.20mV
Pass
90% Load
7.30mV
5.30mV
10.30mV
9.60mV
Pass
100% Load
10.90mV
5.90mV
11.50mV
10.60mV
Pass
110% Load
11.50mV
5.80mV
11.40mV
11.70mV
Pass
Crossload1
10.10mV
4.70mV
11.50mV
8.30mV
Pass
Crossload2
10.80mV
5.90mV
10.30mV
10.20mV
Pass
The results above are not used in the certification process