Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (560mm)
1
1
18-20AWG
No
4+4 pin EPS12V (620mm)
1
1
18AWG
No
6+2 pin PCIe (580mm+110mm)
1
2
18AWG
No
SATA (460mm+120mm+120mm)
2
6
18AWG
No
SATA (460mm) / 4-pin Molex (+120mm+120mm) / FDD (+120mm)
1
1 / 2 / 1
18-20AWG
No
AC Power Cord (1380mm) - C13 coupler
1
1
18AWG
-
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
36
3
0.3
Watts
110
432
15
3.6
Total Max. Power (W)
450
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✗
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
82.734%
Average Noise Output (>1450 Load Combinations)
31.85dBA
Average PF (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
55.611%
Standby Power Consumption
0.0452W
Non-Accredited
12V Ripple (Full Load)
53.24mV
5V Ripple (Full Load)
19.85mV
3.3V Ripple (Full Load)
21.63mV
5VSB Ripple (Full Load)
25.49mV
12V Load Regulation
1.41%
5V Load Regulation
1.11%
3.3V Load Regulation
2.34%
5VSB Load Regulation
3.11%
Inrush Current
43.288A
Accredited
Average Efficiency (>1450 load combinations)
85.151%
Average Noise Output (>1450 Load Combinations)
31.77dBA
Average PF (>1450 Load Combinations)
0.967
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1033W
Non-Accredited
12V Ripple (Full Load)
66.69mV
5V Ripple (Full Load)
26.95mV
3.3V Ripple (Full Load)
21.40mV
5VSB Ripple (Full Load)
30.98mV
12V Load Regulation
1.41%
5V Load Regulation
1.34%
3.3V Load Regulation
2.28%
5VSB Load Regulation
3.07%
Inrush Current
43.109A
Hold-Up Time & PWR_OK Signal
19.60ms
AC Loss to PWR_OK Hold Up Time
15.40ms
PWR_OK Inactive to DC Loss Delay
4.20ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
19.6
AC Loss to PWR_OK Hold Up Time (ms)
15.4
PWR_OK Inactive to DC Loss Delay (ms)
4.2
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.226
72.903%
0.046
5.029V
0.310
115.03V
2
0.090A
0.453
77.702%
0.085
5.029V
0.583
115.03V
3
0.550A
2.761
80.897%
0.299
5.020V
3.413
115.03V
4
1.000A
5.010
81.016%
0.366
5.010V
6.184
115.03V
5
1.500A
7.499
80.634%
0.402
5.000V
9.300
115.03V
6
3.000A
14.900
77.030%
0.450
4.967V
19.343
115.03V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.226
62.259%
0.017
5.029V
0.363
230.18V
2
0.090A
0.453
69.907%
0.030
5.029V
0.648
230.18V
3
0.550A
2.761
77.950%
0.144
5.020V
3.542
230.18V
4
1.000A
5.010
79.853%
0.216
5.010V
6.274
230.18V
5
1.500A
7.499
80.263%
0.268
4.999V
9.343
230.17V
6
3.000A
14.893
79.744%
0.342
4.965V
18.676
230.18V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.902A
1.992A
1.954A
1.001A
44.725
76.102%
715
16.8
35.35°C
0.970
12.163V
5.018V
3.375V
4.995V
58.770
42.16°C
115.04V
2
4.809A
2.992A
2.939A
1.205A
89.220
82.473%
744
17.7
35.91°C
0.987
12.131V
5.009V
3.366V
4.981V
108.181
43.27°C
115.04V
3
8.127A
3.488A
3.422A
1.409A
134.362
84.351%
852
20.8
36.06°C
0.992
12.104V
5.017V
3.359V
4.968V
159.290
44.86°C
115.04V
4
11.448A
3.979A
3.937A
1.614A
179.590
84.938%
943
23.5
36.71°C
0.988
12.089V
5.027V
3.351V
4.957V
211.437
46.49°C
115.04V
5
14.435A
4.979A
4.936A
1.821A
224.896
84.740%
1124
28.2
37.16°C
0.989
12.082V
5.020V
3.342V
4.943V
265.394
47.69°C
115.04V
6
17.364A
5.987A
5.939A
2.029A
269.426
84.257%
1280
32.1
37.51°C
0.991
12.072V
5.013V
3.333V
4.929V
319.766
48.91°C
115.04V
7
20.368A
6.993A
6.947A
2.239A
314.725
83.547%
1470
35.0
38.80°C
0.993
12.059V
5.006V
3.325V
4.914V
376.703
51.11°C
115.04V
8
23.377A
8.006A
7.962A
2.451A
360.035
82.741%
1605
37.5
38.90°C
0.994
12.047V
4.997V
3.316V
4.898V
435.136
52.34°C
115.04V
9
26.835A
8.499A
8.464A
2.455A
404.937
81.834%
1782
40.2
39.38°C
0.994
12.015V
5.002V
3.308V
4.889V
494.829
54.21°C
115.04V
10
30.025A
8.996A
9.002A
3.084A
449.767
80.695%
1897
42.6
39.74°C
0.995
11.992V
5.003V
3.299V
4.865V
557.369
55.95°C
115.03V
11
33.885A
8.972A
9.022A
3.089A
494.565
79.514%
1990
42.8
40.14°C
0.996
11.948V
5.016V
3.292V
4.857V
621.987
58.30°C
115.03V
CL1
0.130A
13.000A
13.000A
0.000A
103.069
75.799%
1375
33.6
37.76°C
0.987
12.644V
4.461V
3.341V
4.969V
135.976
48.08°C
115.05V
CL2
35.998A
1.000A
1.000A
1.000A
435.565
81.387%
1707
39.5
39.45°C
0.995
11.723V
5.298V
3.322V
4.940V
535.177
55.57°C
115.04V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.906A
1.993A
1.954A
1.001A
44.766
77.610%
711
16.8
35.09°C
0.818
12.160V
5.016V
3.374V
4.994V
57.681
41.82°C
230.19V
2
4.811A
2.995A
2.938A
1.205A
89.232
84.076%
734
17.3
35.94°C
0.914
12.128V
5.007V
3.365V
4.980V
106.133
43.22°C
230.18V
3
8.129A
3.488A
3.421A
1.410A
134.353
86.217%
821
20.3
36.24°C
0.949
12.101V
5.015V
3.358V
4.967V
155.832
44.37°C
230.19V
4
11.448A
3.980A
3.936A
1.615A
179.562
86.949%
961
23.7
36.61°C
0.963
12.087V
5.025V
3.350V
4.956V
206.513
45.84°C
230.18V
5
14.433A
4.981A
4.936A
1.821A
224.843
86.967%
1104
28.0
36.93°C
0.971
12.080V
5.019V
3.341V
4.943V
258.537
47.04°C
230.19V
6
17.364A
5.987A
5.939A
2.030A
269.370
86.684%
1251
31.1
37.30°C
0.976
12.069V
5.012V
3.333V
4.928V
310.750
48.25°C
230.19V
7
20.368A
6.998A
6.948A
2.240A
314.668
86.212%
1426
34.0
37.81°C
0.980
12.056V
5.003V
3.324V
4.913V
364.995
49.63°C
230.18V
8
23.371A
8.012A
7.962A
2.450A
359.959
85.645%
1587
37.4
38.01°C
0.982
12.047V
4.994V
3.315V
4.899V
420.294
50.33°C
230.16V
9
26.837A
8.501A
8.467A
2.456A
404.895
85.018%
1790
40.2
38.39°C
0.984
12.013V
5.000V
3.306V
4.888V
476.249
52.76°C
230.16V
10
30.031A
9.001A
9.004A
3.085A
449.754
84.244%
1917
42.6
39.14°C
0.986
11.989V
5.001V
3.298V
4.863V
533.872
54.73°C
230.17V
11
33.893A
8.978A
9.024A
3.091A
494.573
83.496%
1988
42.8
40.22°C
0.987
11.945V
5.014V
3.291V
4.855V
592.332
56.77°C
230.17V
CL1
0.132A
13.002A
12.998A
0.000A
103.045
77.375%
1387
33.7
36.88°C
0.937
12.645V
4.457V
3.341V
4.968V
133.176
47.72°C
230.18V
CL2
35.998A
1.002A
0.999A
1.000A
435.353
84.650%
1772
40.1
39.12°C
0.985
11.717V
5.299V
3.321V
4.937V
514.299
54.60°C
230.17V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.172A
0.489A
0.472A
0.199A
19.347
66.952%
677
15.5
0.922
12.175V
5.078V
3.382V
5.021V
28.897
115.04V
2
2.431A
0.988A
0.972A
0.399A
39.765
76.585%
683
15.9
0.967
12.130V
5.053V
3.378V
5.013V
51.923
115.04V
3
3.623A
1.486A
1.450A
0.600A
59.306
80.235%
693
16.2
0.977
12.122V
5.043V
3.374V
5.004V
73.915
115.04V
4
4.883A
1.985A
1.955A
0.801A
79.744
82.189%
719
16.8
0.982
12.115V
5.036V
3.370V
4.995V
97.025
115.04V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.182A
0.492A
0.472A
0.199A
19.479
68.271%
667
15.2
0.637
12.171V
5.077V
3.382V
5.019V
28.532
230.20V
2
2.440A
0.989A
0.977A
0.399A
39.883
77.913%
674
15.5
0.796
12.126V
5.052V
3.377V
5.012V
51.189
230.18V
3
3.632A
1.484A
1.451A
0.600A
59.390
81.684%
684
16.0
0.862
12.118V
5.042V
3.373V
5.002V
72.707
230.19V
4
4.890A
1.986A
1.955A
0.801A
79.808
83.909%
708
16.8
0.904
12.111V
5.035V
3.369V
4.993V
95.113
230.19V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.2 mV
6.5 mV
8.7 mV
12.3 mV
Pass
20% Load
13.4 mV
7.5 mV
9.6 mV
16.4 mV
Pass
30% Load
15.4 mV
8.9 mV
10.3 mV
15.1 mV
Pass
40% Load
19.0 mV
10.0 mV
11.0 mV
17.6 mV
Pass
50% Load
23.1 mV
11.8 mV
12.5 mV
18.7 mV
Pass
60% Load
34.7 mV
15.9 mV
14.4 mV
19.4 mV
Pass
70% Load
35.6 mV
15.3 mV
15.4 mV
19.7 mV
Pass
80% Load
38.3 mV
16.1 mV
18.7 mV
22.2 mV
Pass
90% Load
46.3 mV
18.2 mV
20.3 mV
22.1 mV
Pass
100% Load
53.2 mV
19.9 mV
21.6 mV
25.5 mV
Pass
110% Load
58.7 mV
21.0 mV
23.2 mV
26.1 mV
Pass
Crossload 1
21.6 mV
37.6 mV
17.5 mV
14.2 mV
Pass
Crossload 2
60.7 mV
18.3 mV
19.0 mV
21.7 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.4 mV
5.9 mV
8.6 mV
11.4 mV
Pass
20% Load
13.9 mV
7.5 mV
9.4 mV
14.3 mV
Pass
30% Load
17.3 mV
8.7 mV
9.8 mV
13.8 mV
Pass
40% Load
20.1 mV
10.2 mV
10.8 mV
15.5 mV
Pass
50% Load
22.7 mV
10.6 mV
12.2 mV
17.3 mV
Pass
60% Load
30.2 mV
14.3 mV
13.7 mV
16.9 mV
Pass
70% Load
35.5 mV
15.5 mV
15.0 mV
17.8 mV
Pass
80% Load
38.3 mV
15.8 mV
18.1 mV
19.0 mV
Pass
90% Load
43.9 mV
17.6 mV
19.8 mV
22.7 mV
Pass
100% Load
66.7 mV
27.0 mV
21.4 mV
31.0 mV
Pass
110% Load
76.9 mV
29.8 mV
23.1 mV
33.7 mV
Pass
Crossload 1
22.1 mV
55.7 mV
17.9 mV
13.1 mV
Fail
Crossload 2
74.1 mV
26.2 mV
18.8 mV
20.6 mV
Pass
The results above are not used in the certification process