ErP Lot 6 2010: Partially
ErP Lot 6 2013: Partially
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
83.878%
Average Noise Output (>1450 Load Combinations)
39.22dBA
Average PF (>1450 Load Combinations)
0.982
Efficiency With 10W (≤500W) or 2% (>500W) Load
50.735%
Standby Power Consumption
0.1460W
Non-Accredited
12V Ripple (Full Load)
52.63mV
5V Ripple (Full Load)
29.92mV
3.3V Ripple (Full Load)
29.88mV
5VSB Ripple (Full Load)
20.22mV
12V Load Regulation
1.37%
5V Load Regulation
2.08%
3.3V Load Regulation
0.59%
5VSB Load Regulation
2.49%
Inrush Current
132.557A
Accredited
Average Efficiency (>1450 load combinations)
85.708%
Average Noise Output (>1450 Load Combinations)
39.40dBA
Average PF (>1450 Load Combinations)
0.937
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.3798W
Non-Accredited
12V Ripple (Full Load)
51.44mV
5V Ripple (Full Load)
27.38mV
3.3V Ripple (Full Load)
27.62mV
5VSB Ripple (Full Load)
20.89mV
12V Load Regulation
1.35%
5V Load Regulation
2.08%
3.3V Load Regulation
0.59%
5VSB Load Regulation
2.51%
Inrush Current
75.008A
Hold-Up Time & PWR_OK Signal
11.40ms
AC Loss to PWR_OK Hold Up Time
93.00ms
PWR_OK Inactive to DC Loss Delay
-81.60ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
11.4
AC Loss to PWR_OK Hold Up Time (ms)
93
PWR_OK Inactive to DC Loss Delay (ms)
-81.6
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
50.658%
0.060
5.112V
0.456
115.11V
2
0.090A
0.460
59.585%
0.097
5.110V
0.772
115.11V
3
0.550A
2.805
76.723%
0.258
5.099V
3.656
115.12V
4
1.000A
5.088
77.349%
0.303
5.087V
6.578
115.12V
5
1.500A
7.613
78.002%
0.326
5.074V
9.760
115.12V
6
2.500A
12.621
77.056%
0.353
5.048V
16.379
115.12V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
32.624%
0.029
5.112V
0.705
230.24V
2
0.090A
0.460
43.315%
0.043
5.111V
1.062
230.25V
3
0.550A
2.805
69.776%
0.140
5.098V
4.020
230.23V
4
1.000A
5.088
73.622%
0.198
5.087V
6.911
230.23V
5
1.500A
7.612
74.358%
0.236
5.074V
10.237
230.24V
6
2.500A
12.620
76.052%
0.274
5.048V
16.594
230.24V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.742A
1.950A
1.958A
0.984A
79.976
77.893%
888
21.5
29.48°C
0.951
12.313V
5.126V
3.367V
5.080V
102.674
31.10°C
115.11V
2
10.475A
2.932A
2.940A
1.184A
159.706
83.677%
892
21.9
29.85°C
0.959
12.297V
5.115V
3.366V
5.068V
190.859
31.77°C
115.11V
3
16.578A
3.426A
3.417A
1.384A
239.581
85.786%
1027
25.9
30.36°C
0.976
12.281V
5.106V
3.364V
5.057V
279.279
32.51°C
115.11V
4
22.699A
3.924A
3.925A
1.586A
319.570
86.523%
1363
34.3
30.86°C
0.984
12.264V
5.096V
3.361V
5.045V
369.349
33.76°C
115.11V
5
28.514A
4.916A
4.907A
1.788A
399.690
86.627%
1636
39.2
31.16°C
0.988
12.247V
5.084V
3.360V
5.033V
461.390
34.22°C
115.10V
6
34.345A
5.913A
5.896A
1.992A
479.796
86.434%
1719
40.8
31.43°C
0.990
12.229V
5.073V
3.357V
5.021V
555.099
34.81°C
115.10V
7
40.168A
6.916A
6.884A
2.196A
559.506
86.027%
1722
41.0
32.20°C
0.992
12.209V
5.061V
3.355V
5.008V
650.382
35.89°C
115.10V
8
46.065A
7.924A
7.874A
2.402A
640.025
85.423%
1724
41.0
33.38°C
0.993
12.192V
5.048V
3.353V
4.995V
749.241
37.49°C
115.09V
9
52.317A
8.438A
8.354A
2.406A
719.361
84.717%
1719
40.8
33.88°C
0.993
12.173V
5.038V
3.351V
4.988V
849.135
38.61°C
115.09V
10
58.666A
8.954A
8.868A
2.512A
800.057
83.819%
1718
40.8
34.79°C
0.994
12.151V
5.027V
3.348V
4.978V
954.500
40.05°C
115.09V
11
65.363A
8.970A
8.876A
2.515A
880.056
82.806%
1723
41.0
35.08°C
0.992
12.130V
5.017V
3.346V
4.971V
1062.794
41.05°C
115.08V
CL1
0.136A
16.002A
15.997A
0.000A
136.650
74.519%
1712
40.7
31.01°C
0.953
12.303V
5.068V
3.368V
5.088V
183.377
34.72°C
115.11V
CL2
60.000A
1.000A
0.998A
1.000A
743.282
84.833%
1724
41.0
34.91°C
0.994
12.164V
5.066V
3.350V
5.032V
876.166
40.53°C
115.08V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.746A
1.950A
1.959A
0.984A
80.019
78.930%
890
21.7
28.82°C
0.848
12.311V
5.126V
3.367V
5.080V
101.380
30.55°C
230.25V
2
10.480A
2.932A
2.940A
1.184A
159.740
85.240%
894
22.0
29.37°C
0.903
12.295V
5.114V
3.365V
5.068V
187.401
31.33°C
230.25V
3
16.581A
3.428A
3.418A
1.384A
239.608
87.355%
1085
27.9
30.52°C
0.923
12.280V
5.105V
3.363V
5.057V
274.293
32.79°C
230.25V
4
22.704A
3.925A
3.926A
1.586A
319.615
88.090%
1369
34.4
30.94°C
0.937
12.263V
5.095V
3.361V
5.045V
362.829
33.57°C
230.25V
5
28.520A
4.918A
4.910A
1.788A
399.716
88.293%
1646
39.3
31.44°C
0.949
12.245V
5.083V
3.359V
5.033V
452.715
34.56°C
230.25V
6
34.346A
5.915A
5.898A
1.992A
479.779
88.218%
1724
41.0
32.54°C
0.953
12.228V
5.071V
3.357V
5.021V
543.856
35.96°C
230.25V
7
40.159A
6.917A
6.883A
2.196A
559.458
87.953%
1723
41.0
32.74°C
0.958
12.211V
5.059V
3.354V
5.008V
636.091
36.47°C
230.24V
8
46.062A
7.926A
7.873A
2.402A
639.979
87.504%
1719
40.8
33.21°C
0.962
12.192V
5.047V
3.352V
4.995V
731.368
37.64°C
230.24V
9
52.313A
8.438A
8.356A
2.406A
719.293
86.983%
1722
41.0
34.22°C
0.967
12.173V
5.036V
3.350V
4.988V
826.936
38.78°C
230.23V
10
58.667A
8.955A
8.870A
2.512A
800.003
86.144%
1724
41.0
35.07°C
0.972
12.150V
5.025V
3.348V
4.977V
928.678
39.88°C
230.22V
11
65.353A
8.970A
8.878A
2.515A
879.998
85.734%
1725
41.0
35.25°C
0.976
12.131V
5.017V
3.345V
4.971V
1026.425
40.21°C
230.23V
CL1
0.130A
16.001A
16.000A
0.000A
136.564
75.963%
1716
40.8
31.31°C
0.899
12.303V
5.067V
3.368V
5.087V
179.776
34.74°C
230.22V
CL2
59.997A
0.999A
0.998A
1.000A
743.239
87.231%
1725
41.0
35.28°C
0.968
12.164V
5.065V
3.350V
5.032V
852.034
39.74°C
230.23V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.169A
0.487A
0.474A
0.196A
19.507
54.457%
876
21.2
0.877
12.324V
5.139V
3.369V
5.105V
35.821
115.12V
2
2.405A
0.973A
0.980A
0.392A
39.925
67.681%
880
21.3
0.928
12.320V
5.134V
3.368V
5.099V
58.990
115.12V
3
3.576A
1.461A
1.451A
0.589A
59.406
74.660%
882
21.3
0.950
12.311V
5.130V
3.368V
5.092V
79.569
115.12V
4
4.807A
1.950A
1.956A
0.787A
79.773
77.835%
886
21.4
0.952
12.313V
5.126V
3.367V
5.085V
102.490
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.172A
0.486A
0.476A
0.196A
19.546
55.919%
886
21.4
0.598
12.324V
5.139V
3.369V
5.106V
34.954
230.26V
2
2.409A
0.973A
0.980A
0.392A
39.969
69.088%
886
21.4
0.740
12.318V
5.134V
3.368V
5.099V
57.852
230.26V
3
3.578A
1.460A
1.454A
0.589A
59.449
75.355%
888
21.5
0.811
12.315V
5.130V
3.368V
5.092V
78.892
230.26V
4
4.811A
1.951A
1.958A
0.787A
79.821
78.855%
888
21.5
0.849
12.311V
5.125V
3.367V
5.085V
101.225
230.26V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
15.4 mV
42.7 mV
24.6 mV
8.6 mV
Pass
20% Load
14.8 mV
37.2 mV
24.1 mV
10.3 mV
Pass
30% Load
17.0 mV
37.7 mV
23.7 mV
11.1 mV
Pass
40% Load
20.7 mV
35.1 mV
23.6 mV
12.1 mV
Pass
50% Load
23.8 mV
33.9 mV
23.4 mV
12.0 mV
Pass
60% Load
28.6 mV
35.5 mV
25.2 mV
12.8 mV
Pass
70% Load
31.9 mV
36.8 mV
27.0 mV
13.8 mV
Pass
80% Load
36.5 mV
34.9 mV
29.6 mV
15.0 mV
Pass
90% Load
43.2 mV
30.7 mV
27.3 mV
17.9 mV
Pass
100% Load
52.6 mV
29.9 mV
29.9 mV
20.2 mV
Pass
110% Load
65.5 mV
30.0 mV
31.6 mV
24.6 mV
Pass
Crossload 1
14.9 mV
79.1 mV
51.7 mV
6.6 mV
Fail
Crossload 2
52.3 mV
25.6 mV
28.5 mV
15.0 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.6 mV
44.2 mV
25.6 mV
8.2 mV
Pass
20% Load
16.2 mV
37.8 mV
23.7 mV
9.3 mV
Pass
30% Load
16.9 mV
37.2 mV
23.8 mV
10.1 mV
Pass
40% Load
20.3 mV
34.8 mV
22.8 mV
11.1 mV
Pass
50% Load
25.3 mV
34.5 mV
23.9 mV
10.8 mV
Pass
60% Load
28.4 mV
37.3 mV
26.9 mV
12.6 mV
Pass
70% Load
33.2 mV
36.5 mV
27.2 mV
13.9 mV
Pass
80% Load
36.3 mV
34.2 mV
27.6 mV
15.7 mV
Pass
90% Load
42.9 mV
29.0 mV
26.5 mV
17.5 mV
Pass
100% Load
51.4 mV
27.4 mV
27.6 mV
20.9 mV
Pass
110% Load
68.1 mV
36.4 mV
35.6 mV
23.7 mV
Pass
Crossload 1
15.5 mV
81.5 mV
50.9 mV
6.7 mV
Fail
Crossload 2
50.5 mV
24.4 mV
26.7 mV
14.2 mV
Pass
The results above are not used in the certification process