ErP Lot 6 2010: ✓
ErP Lot 6 2013: Partially
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
84.327%
Average Noise Output (>1450 Load Combinations)
37.51dBA
Average PF (>1450 Load Combinations)
0.988
Efficiency With 10W (≤500W) or 2% (>500W) Load
55.120%
Standby Power Consumption
0.1072W
Non-Accredited
12V Ripple (Full Load)
30.13mV
5V Ripple (Full Load)
22.92mV
3.3V Ripple (Full Load)
22.70mV
5VSB Ripple (Full Load)
42.16mV
12V Load Regulation
1.00%
5V Load Regulation
2.25%
3.3V Load Regulation
1.92%
5VSB Load Regulation
2.13%
Inrush Current
99.284A
Accredited
Average Efficiency (>1450 load combinations)
86.040%
Average Noise Output (>1450 Load Combinations)
37.49dBA
Average PF (>1450 Load Combinations)
0.945
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1890W
Non-Accredited
12V Ripple (Full Load)
26.83mV
5V Ripple (Full Load)
20.90mV
3.3V Ripple (Full Load)
23.99mV
5VSB Ripple (Full Load)
38.46mV
12V Load Regulation
0.99%
5V Load Regulation
2.35%
3.3V Load Regulation
1.83%
5VSB Load Regulation
2.09%
Inrush Current
66.130A
Hold-Up Time & PWR_OK Signal
12.50ms
AC Loss to PWR_OK Hold Up Time
8.10ms
PWR_OK Inactive to DC Loss Delay
4.40ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
12.50
AC Loss to PWR_OK Hold Up Time (ms)
8.10
PWR_OK Inactive to DC Loss Delay (ms)
4.40
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
53.349%
0.068
5.137V
0.433
115.10V
2
0.090A
0.462
61.682%
0.112
5.134V
0.749
115.10V
3
0.550A
2.820
74.722%
0.290
5.126V
3.774
115.10V
4
1.000A
5.120
76.190%
0.332
5.120V
6.720
115.10V
5
1.500A
7.669
75.998%
0.356
5.112V
10.091
115.10V
6
2.501A
12.743
74.420%
0.385
5.096V
17.123
115.10V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
43.667%
0.026
5.134V
0.529
230.28V
2
0.090A
0.462
53.534%
0.041
5.133V
0.863
230.28V
3
0.550A
2.820
71.320%
0.160
5.126V
3.954
230.26V
4
1.000A
5.121
74.390%
0.226
5.120V
6.884
230.26V
5
1.500A
7.669
74.922%
0.269
5.112V
10.236
230.26V
6
2.501A
12.744
75.377%
0.315
5.096V
16.907
230.25V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.262A
1.971A
1.980A
0.979A
49.553
78.666%
1018
25.6
29.03°C
0.966
12.359V
5.076V
3.328V
5.110V
62.992
30.88°C
115.10V
2
5.563A
2.962A
2.981A
1.177A
99.634
84.383%
1022
25.8
29.69°C
0.963
12.357V
5.062V
3.320V
5.099V
118.073
32.00°C
115.09V
3
9.204A
3.461A
3.469A
1.376A
149.522
86.071%
1022
25.8
30.25°C
0.977
12.335V
5.056V
3.312V
5.089V
173.719
32.90°C
115.08V
4
12.865A
3.959A
3.989A
1.575A
199.556
86.559%
1029
26.0
30.90°C
0.986
12.310V
5.052V
3.306V
5.079V
230.542
33.78°C
115.07V
5
16.186A
4.962A
4.997A
1.776A
249.675
86.311%
1247
32.0
31.16°C
0.991
12.306V
5.038V
3.300V
5.069V
289.272
34.56°C
115.08V
6
19.514A
5.970A
6.010A
1.978A
299.785
85.681%
1498
36.9
31.61°C
0.993
12.298V
5.025V
3.294V
5.058V
349.883
35.46°C
115.09V
7
22.838A
6.987A
7.026A
2.180A
349.893
84.865%
1736
41.3
32.49°C
0.995
12.295V
5.010V
3.287V
5.046V
412.296
36.90°C
115.09V
8
26.161A
8.009A
8.042A
2.383A
400.023
84.010%
1737
41.3
33.53°C
0.996
12.294V
4.995V
3.282V
5.036V
476.162
38.26°C
115.09V
9
29.935A
8.517A
8.544A
2.386A
449.742
83.133%
1726
41.0
33.80°C
0.996
12.268V
4.990V
3.277V
5.030V
540.994
39.21°C
115.09V
10
33.743A
9.026A
9.092A
2.491A
500.055
82.111%
1729
41.1
35.24°C
0.996
12.235V
4.986V
3.267V
5.019V
608.996
41.17°C
115.09V
11
37.968A
9.019A
9.105A
2.496A
549.677
80.930%
1718
40.8
35.88°C
0.997
12.181V
4.989V
3.261V
5.009V
679.198
42.61°C
115.09V
CL1
0.136A
12.000A
12.001A
0.000A
99.215
76.531%
1364
34.3
31.74°C
0.971
12.939V
4.817V
3.304V
5.105V
129.640
34.72°C
115.10V
CL2
31.993A
1.001A
0.999A
1.000A
393.809
84.564%
1689
40.2
35.93°C
0.996
11.886V
5.169V
3.294V
5.075V
465.696
41.16°C
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.268A
1.967A
1.981A
0.979A
49.608
79.695%
1014
25.3
28.90°C
0.595
12.358V
5.076V
3.328V
5.110V
62.247
30.87°C
230.30V
2
5.569A
2.962A
2.980A
1.177A
99.702
85.237%
1016
25.5
29.55°C
0.817
12.357V
5.061V
3.320V
5.099V
116.970
31.86°C
230.30V
3
9.210A
3.462A
3.469A
1.376A
149.601
87.290%
1019
25.7
30.21°C
0.912
12.335V
5.056V
3.312V
5.089V
171.383
32.83°C
230.30V
4
12.869A
3.959A
3.989A
1.575A
199.607
87.971%
1025
25.9
30.87°C
0.942
12.310V
5.052V
3.306V
5.080V
226.901
33.87°C
230.29V
5
16.188A
4.962A
4.997A
1.776A
249.700
87.916%
1255
32.1
31.07°C
0.965
12.306V
5.038V
3.300V
5.069V
284.021
34.70°C
230.29V
6
19.516A
5.969A
6.010A
1.978A
299.795
87.522%
1487
36.6
31.79°C
0.978
12.298V
5.024V
3.294V
5.057V
342.535
35.78°C
230.27V
7
22.836A
6.987A
7.027A
2.180A
349.888
86.936%
1721
40.9
32.38°C
0.984
12.296V
5.009V
3.287V
5.046V
402.465
37.18°C
230.27V
8
26.157A
8.012A
8.042A
2.383A
400.007
86.320%
1725
41.0
33.36°C
0.985
12.295V
4.994V
3.282V
5.036V
463.401
38.54°C
230.27V
9
29.933A
8.518A
8.543A
2.386A
449.720
85.725%
1724
41.0
33.62°C
0.986
12.268V
4.990V
3.277V
5.030V
524.609
39.46°C
230.26V
10
33.739A
9.030A
9.089A
2.491A
500.041
84.984%
1722
41.0
34.41°C
0.987
12.236V
4.985V
3.267V
5.019V
588.396
40.65°C
230.27V
11
37.970A
9.020A
9.104A
2.496A
549.674
84.156%
1716
40.8
35.79°C
0.988
12.180V
4.989V
3.262V
5.009V
653.161
42.39°C
230.28V
CL1
0.134A
12.000A
12.001A
0.000A
99.176
77.618%
1389
34.7
31.23°C
0.850
12.937V
4.817V
3.303V
5.105V
127.774
34.75°C
230.29V
CL2
32.005A
1.002A
0.997A
1.000A
393.919
86.870%
1689
40.2
34.14°C
0.985
11.885V
5.169V
3.295V
5.075V
453.459
40.50°C
230.29V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.164A
0.487A
0.476A
0.195A
19.359
66.894%
1006
24.8
0.841
12.267V
5.121V
3.334V
5.128V
28.940
115.11V
2
2.403A
0.979A
0.987A
0.391A
39.856
77.567%
1011
25.1
0.949
12.306V
5.101V
3.331V
5.121V
51.383
115.10V
3
3.563A
1.474A
1.469A
0.587A
59.290
81.782%
1013
25.2
0.987
12.320V
5.090V
3.328V
5.115V
72.498
115.09V
4
4.798A
1.966A
1.983A
0.783A
79.727
83.488%
1016
25.5
0.967
12.327V
5.081V
3.324V
5.110V
95.495
115.09V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.171A
0.487A
0.476A
0.195A
19.443
67.677%
1007
24.8
0.399
12.265V
5.121V
3.334V
5.128V
28.729
230.29V
2
2.408A
0.980A
0.988A
0.391A
39.923
78.527%
1007
24.8
0.545
12.305V
5.101V
3.331V
5.121V
50.840
230.29V
3
3.569A
1.473A
1.469A
0.587A
59.353
82.144%
1010
25.0
0.669
12.319V
5.090V
3.327V
5.115V
72.255
230.30V
4
4.803A
1.968A
1.981A
0.783A
79.791
84.297%
1011
25.1
0.759
12.327V
5.080V
3.324V
5.110V
94.655
230.29V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.7 mV
8.7 mV
11.7 mV
13.4 mV
Pass
20% Load
8.9 mV
9.0 mV
21.3 mV
14.5 mV
Pass
30% Load
11.1 mV
9.4 mV
13.8 mV
15.9 mV
Pass
40% Load
12.5 mV
9.7 mV
14.4 mV
16.7 mV
Pass
50% Load
13.7 mV
10.6 mV
15.5 mV
18.4 mV
Pass
60% Load
15.7 mV
12.2 mV
17.5 mV
23.3 mV
Pass
70% Load
17.6 mV
13.7 mV
20.2 mV
25.1 mV
Pass
80% Load
19.0 mV
15.4 mV
19.5 mV
32.5 mV
Pass
90% Load
21.0 mV
17.1 mV
24.0 mV
36.8 mV
Pass
100% Load
30.1 mV
22.9 mV
22.7 mV
42.2 mV
Pass
110% Load
36.1 mV
26.8 mV
23.6 mV
54.7 mV
Fail
Crossload 1
12.7 mV
72.7 mV
24.0 mV
28.2 mV
Fail
Crossload 2
23.6 mV
18.9 mV
15.1 mV
20.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.0 mV
8.7 mV
13.5 mV
13.2 mV
Pass
20% Load
8.4 mV
8.2 mV
13.5 mV
14.6 mV
Pass
30% Load
9.4 mV
9.3 mV
13.1 mV
15.6 mV
Pass
40% Load
10.6 mV
9.5 mV
13.6 mV
15.9 mV
Pass
50% Load
11.2 mV
10.0 mV
15.1 mV
18.8 mV
Pass
60% Load
12.0 mV
11.3 mV
17.1 mV
23.2 mV
Pass
70% Load
13.6 mV
12.8 mV
17.1 mV
27.0 mV
Pass
80% Load
16.1 mV
13.6 mV
21.0 mV
30.3 mV
Pass
90% Load
18.0 mV
15.6 mV
20.8 mV
34.8 mV
Pass
100% Load
26.8 mV
20.9 mV
24.0 mV
38.5 mV
Pass
110% Load
30.5 mV
24.8 mV
24.4 mV
50.5 mV
Fail
Crossload 1
12.2 mV
61.8 mV
27.1 mV
28.2 mV
Fail
Crossload 2
18.1 mV
17.0 mV
15.3 mV
20.7 mV
Pass
The results above are not used in the certification process
Gamemax GM500 rev.2
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern