140mm Hydro Dynamic Bearing Fan [TT-1425 (A1425L12S)]
Semi-Passive Operation
✓ (selectable)
Cybenetics Testing Information
Lab ID
617
Date of receipt
Jan 22, 2019
Testing Date
Jan 27, 2019
Report Issued Date
Jan 31, 2019
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
18AWG
No
4+4 pin EPS12V (650mm)
1
1
16AWG
No
8 pin EPS12V (650mm)
1
1
16AWG
No
6+2 pin PCIe (700mm+150mm)
3
6
16-18AWG
No
SATA (500mm+150mm+150mm+150mm)
3
12
18AWG
No
4 pin Molex (500mm+150mm+150mm+150mm)
1
4
18AWG
No
FDD Adapter (100mm)
1
1
22AWG
No
AC Power Cord (1420mm) - C13 coupler
1
1
18AWG
-
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
22
22
70.9
3
0.3
Watts
120
850
15
3.6
Total Max. Power (W)
850
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
89.216%
Average Noise Output (>1450 Load Combinations)
28.45dBA
Average PF (>1450 Load Combinations)
0.979
Efficiency With 10W (≤500W) or 2% (>500W) Load
69.051%
Standby Power Consumption
0.0470W
Non-Accredited
12V Ripple (Full Load)
14.01mV
5V Ripple (Full Load)
15.07mV
3.3V Ripple (Full Load)
11.87mV
5VSB Ripple (Full Load)
13.94mV
12V Load Regulation
0.52%
5V Load Regulation
0.20%
3.3V Load Regulation
0.42%
5VSB Load Regulation
1.62%
Inrush Current
32.788A
Accredited
Average Efficiency (>1450 load combinations)
90.852%
Average Noise Output (>1450 Load Combinations)
27.91dBA
Average PF (>1450 Load Combinations)
0.937
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0609W
Non-Accredited
12V Ripple (Full Load)
-
5V Ripple (Full Load)
-
3.3V Ripple (Full Load)
-
5VSB Ripple (Full Load)
-
12V Load Regulation
-
5V Load Regulation
-
3.3V Load Regulation
-
5VSB Load Regulation
-
Inrush Current
66.240A
Hold-Up Time & PWR_OK Signal
20.00ms
AC Loss to PWR_OK Hold Up Time
18.60ms
PWR_OK Inactive to DC Loss Delay
1.40ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
20
AC Loss to PWR_OK Hold Up Time (ms)
18.6
PWR_OK Inactive to DC Loss Delay (ms)
1.4
Vampire Power
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
69.605%
0.033
5.078V
0.329
115.14V
2
0.090A
0.458
74.959%
0.061
5.078V
0.611
115.14V
3
0.550A
2.788
79.025%
0.264
5.067V
3.528
115.12V
4
1.000A
5.056
78.705%
0.356
5.055V
6.424
115.13V
5
1.500A
7.566
78.266%
0.409
5.044V
9.667
115.13V
6
3.000A
15.012
76.176%
0.472
5.004V
19.707
115.14V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
65.616%
0.011
5.078V
0.349
230.24V
2
0.090A
0.457
71.743%
0.019
5.078V
0.637
230.24V
3
0.550A
2.787
77.980%
0.101
5.067V
3.574
230.24V
4
1.000A
5.056
78.182%
0.169
5.055V
6.467
230.24V
5
1.500A
7.563
78.025%
0.227
5.042V
9.693
230.24V
6
3.000A
15.007
76.991%
0.330
5.002V
19.492
230.22V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.264A
1.994A
1.996A
0.991A
84.845
87.408%
0
<6.0
43.65°C
0.962
12.015V
5.014V
3.305V
5.048V
97.068
39.46°C
115.11V
2
11.527A
2.992A
2.994A
1.191A
169.337
90.870%
0
<6.0
44.87°C
0.980
12.010V
5.014V
3.304V
5.040V
186.350
40.25°C
115.11V
3
18.196A
3.491A
3.483A
1.391A
254.429
91.733%
0
<6.0
46.04°C
0.983
12.004V
5.013V
3.302V
5.034V
277.359
40.92°C
115.11V
4
24.879A
3.992A
3.997A
1.591A
339.629
91.648%
536
8.8
41.46°C
0.979
11.995V
5.012V
3.301V
5.030V
370.581
47.97°C
115.11V
5
31.239A
4.990A
4.998A
1.792A
424.995
91.257%
578
9.6
42.17°C
0.978
11.988V
5.011V
3.300V
5.024V
465.713
48.49°C
115.11V
6
37.528A
5.990A
6.003A
1.993A
509.470
90.694%
795
18.8
42.80°C
0.980
11.982V
5.010V
3.298V
5.019V
561.749
49.79°C
115.11V
7
43.901A
6.991A
7.010A
2.195A
594.793
89.402%
1304
33.6
43.34°C
0.982
11.974V
5.008V
3.296V
5.014V
665.299
51.30°C
115.11V
8
50.281A
7.993A
8.014A
2.396A
680.123
88.683%
1526
37.6
43.82°C
0.983
11.967V
5.006V
3.294V
5.008V
766.918
52.37°C
115.11V
9
57.064A
8.493A
8.504A
2.397A
765.046
88.046%
1526
37.6
44.20°C
0.985
11.961V
5.005V
3.292V
5.007V
868.914
53.31°C
115.11V
10
63.585A
8.995A
9.023A
3.007A
849.866
87.163%
1525
37.6
45.50°C
0.986
11.955V
5.004V
3.291V
4.989V
975.033
55.32°C
115.10V
11
70.699A
8.995A
9.025A
3.009A
934.632
86.267%
1524
37.6
46.86°C
0.988
11.951V
5.004V
3.290V
4.987V
1083.419
57.04°C
115.11V
CL1
0.144A
14.003A
13.999A
0.000A
118.082
83.744%
540
8.9
42.35°C
0.972
12.007V
5.009V
3.301V
5.069V
141.004
48.35°C
115.13V
CL2
70.836A
1.002A
1.001A
1.000A
860.699
87.776%
1525
37.6
45.19°C
0.987
11.962V
5.011V
3.295V
5.039V
980.567
55.22°C
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.265A
1.994A
1.995A
0.991A
84.811
86.742%
0
<6.0
43.83°C
0.805
12.007V
5.015V
3.305V
5.046V
97.774
39.34°C
230.24V
2
11.534A
2.990A
2.996A
1.191A
169.286
90.411%
536
8.8
40.68°C
0.909
11.999V
5.013V
3.304V
5.040V
187.241
45.42°C
230.24V
3
18.198A
3.492A
3.482A
1.390A
254.394
92.224%
537
8.8
41.08°C
0.937
12.001V
5.012V
3.302V
5.036V
275.843
46.78°C
230.24V
4
24.879A
3.991A
3.998A
1.591A
339.595
92.739%
537
8.8
41.61°C
0.951
11.994V
5.011V
3.300V
5.031V
366.185
47.88°C
230.24V
5
31.233A
4.989A
5.001A
1.791A
424.919
92.718%
587
10.1
42.16°C
0.957
11.988V
5.011V
3.299V
5.025V
458.292
49.02°C
230.24V
6
37.528A
5.990A
6.001A
1.993A
509.422
92.452%
963
25.0
42.79°C
0.961
11.981V
5.009V
3.298V
5.019V
551.012
50.36°C
230.25V
7
43.900A
6.991A
7.005A
2.194A
594.759
92.122%
1272
33.3
43.19°C
0.963
11.974V
5.008V
3.296V
5.014V
645.619
51.24°C
230.24V
8
50.279A
7.992A
8.014A
2.397A
680.099
91.684%
1527
37.6
43.79°C
0.964
11.967V
5.006V
3.294V
5.008V
741.782
52.82°C
230.25V
9
57.056A
8.493A
8.503A
2.397A
765.003
91.325%
1527
37.6
44.58°C
0.967
11.962V
5.005V
3.292V
5.006V
837.673
54.46°C
230.24V
10
63.581A
8.994A
9.025A
3.007A
849.828
90.821%
1526
37.6
45.61°C
0.969
11.955V
5.005V
3.291V
4.989V
935.715
55.86°C
230.24V
11
70.696A
8.994A
9.026A
3.008A
934.589
90.396%
1526
37.6
46.58°C
0.970
11.951V
5.004V
3.290V
4.987V
1033.884
57.57°C
230.24V
CL1
0.141A
14.001A
13.998A
0.000A
118.030
83.099%
572
<6.0
42.60°C
0.875
11.998V
5.009V
3.301V
5.069V
142.035
49.32°C
230.24V
CL2
70.832A
1.001A
0.999A
1.000A
860.566
91.492%
1525
37.6
45.95°C
0.969
11.961V
5.009V
3.295V
5.039V
940.591
55.61°C
230.24V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.205A
0.499A
0.481A
0.197A
19.563
70.416%
0
<6.0
0.786
12.009V
5.015V
3.306V
5.071V
27.782
115.10V
2
2.466A
0.997A
0.997A
0.395A
39.931
81.032%
0
<6.0
0.904
12.018V
5.014V
3.305V
5.065V
49.278
115.11V
3
3.666A
1.496A
1.483A
0.593A
59.453
85.049%
0
<6.0
0.943
12.016V
5.014V
3.305V
5.060V
69.904
115.10V
4
4.929A
1.994A
1.997A
0.792A
79.827
87.145%
0
<6.0
0.959
12.016V
5.014V
3.305V
5.054V
91.603
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.205A
0.494A
0.483A
0.197A
19.550
70.230%
0
<6.0
0.431
12.013V
5.016V
3.307V
5.069V
27.837
230.26V
2
2.465A
0.996A
0.998A
0.395A
39.900
79.933%
0
<6.0
0.600
12.010V
5.016V
3.306V
5.063V
49.917
230.25V
3
3.665A
1.495A
1.480A
0.593A
59.398
84.032%
0
<6.0
0.720
12.008V
5.015V
3.305V
5.058V
70.685
230.24V
4
4.933A
1.993A
1.995A
0.792A
79.818
86.373%
0
<6.0
0.792
12.007V
5.014V
3.305V
5.053V
92.411
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
26.1 mV
12.5 mV
6.2 mV
7.6 mV
Pass
20% Load
9.0 mV
11.8 mV
6.8 mV
5.6 mV
Pass
30% Load
8.8 mV
12.1 mV
7.2 mV
5.5 mV
Pass
40% Load
8.7 mV
13.2 mV
7.8 mV
7.5 mV
Pass
50% Load
8.3 mV
13.1 mV
8.2 mV
9.3 mV
Pass
60% Load
8.1 mV
13.7 mV
8.8 mV
9.8 mV
Pass
70% Load
8.4 mV
14.0 mV
9.6 mV
10.8 mV
Pass
80% Load
9.7 mV
25.7 mV
20.2 mV
12.4 mV
Pass
90% Load
9.4 mV
15.4 mV
12.7 mV
11.7 mV
Pass
100% Load
14.0 mV
15.1 mV
11.9 mV
13.9 mV
Pass
110% Load
13.8 mV
16.0 mV
12.4 mV
13.4 mV
Pass
Crossload 1
10.9 mV
14.4 mV
9.8 mV
5.4 mV
Pass
Crossload 2
13.7 mV
13.4 mV
9.1 mV
12.0 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
2.7 mV
11.5 mV
6.4 mV
8.0 mV
Pass
20% Load
8.1 mV
12.1 mV
7.0 mV
5.1 mV
Pass
30% Load
11.8 mV
12.2 mV
7.7 mV
5.3 mV
Pass
40% Load
9.4 mV
12.6 mV
8.1 mV
7.7 mV
Pass
50% Load
8.6 mV
13.9 mV
9.0 mV
10.1 mV
Pass
60% Load
8.3 mV
14.4 mV
9.9 mV
10.6 mV
Pass
70% Load
9.1 mV
14.0 mV
9.5 mV
11.4 mV
Pass
80% Load
9.6 mV
26.6 mV
20.7 mV
11.9 mV
Pass
90% Load
9.3 mV
15.7 mV
12.3 mV
12.6 mV
Pass
100% Load
13.1 mV
15.3 mV
12.1 mV
12.2 mV
Pass
110% Load
14.0 mV
16.2 mV
12.8 mV
13.3 mV
Pass
Crossload 1
5.4 mV
14.0 mV
10.1 mV
5.2 mV
Pass
Crossload 2
13.5 mV
13.7 mV
9.5 mV
11.1 mV
Pass
The results above are not used in the certification process
Thermaltake Toughpower GF1 850W (#2)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure