Globe Fan S1201512HB (120mm, 12V, 0.45A, Fluid Dynamic Bearing Fan)
5VSB Circuit
Standby PWM Controller
Excelliance EM8569C
Rectifier
MBR1045ULPS (45V, 10A @ 90°C)
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.541%
Average Noise Output (>1450 Load Combinations)
36.91dBA
Average PF (>1450 Load Combinations)
0.984
Efficiency With 10W (≤500W) or 2% (>500W) Load
64.200%
Standby Power Consumption
0.0459W
Non-Accredited
12V Ripple (Full Load)
24.81mV
5V Ripple (Full Load)
23.27mV
3.3V Ripple (Full Load)
21.35mV
5VSB Ripple (Full Load)
18.92mV
12V Load Regulation
0.05%
5V Load Regulation
0.36%
3.3V Load Regulation
0.45%
5VSB Load Regulation
2.10%
Inrush Current
33.513A
Accredited
Average Efficiency (>1450 load combinations)
90.650%
Average Noise Output (>1450 Load Combinations)
36.53dBA
Average PF (>1450 Load Combinations)
0.944
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0730W
Non-Accredited
12V Ripple (Full Load)
34.56mV
5V Ripple (Full Load)
24.01mV
3.3V Ripple (Full Load)
20.97mV
5VSB Ripple (Full Load)
17.23mV
12V Load Regulation
0.06%
5V Load Regulation
0.36%
3.3V Load Regulation
0.42%
5VSB Load Regulation
2.09%
Inrush Current
56.094A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
19.00ms
AC Loss to PWR_OK Hold Up Time
16.60ms
PWR_OK Inactive to DC Loss Delay
2.40ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19.0
AC Loss to PWR_OK Hold Up Time (ms)
16.6
PWR_OK Inactive to DC Loss Delay (ms)
2.4
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
68.546%
0.056
5.136V
0.337
115.11V
2
0.090A
0.462
73.217%
0.101
5.135V
0.631
115.11V
3
0.550A
2.820
77.387%
0.337
5.126V
3.644
115.11V
4
1.000A
5.120
77.365%
0.405
5.119V
6.618
115.11V
5
1.500A
7.667
77.711%
0.439
5.111V
9.866
115.11V
6
3.000A
15.235
75.940%
0.482
5.078V
20.062
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
62.264%
0.019
5.136V
0.371
230.30V
2
0.090A
0.463
68.899%
0.034
5.135V
0.672
230.30V
3
0.550A
2.820
76.196%
0.161
5.126V
3.701
230.30V
4
1.000A
5.120
76.900%
0.242
5.118V
6.658
230.29V
5
1.500A
7.665
77.012%
0.296
5.109V
9.953
230.28V
6
3.000A
15.252
77.689%
0.369
5.084V
19.632
230.28V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.619A
2.004A
1.990A
0.978A
64.819
84.899%
0
<6.0
43.77°C
0.960
11.944V
4.992V
3.312V
5.112V
76.348
39.04°C
115.12V
2
8.243A
3.007A
2.989A
1.176A
129.342
88.998%
932
19.7
39.53°C
0.978
11.943V
4.989V
3.310V
5.103V
145.332
44.61°C
115.12V
3
13.271A
3.510A
3.475A
1.374A
194.470
89.648%
939
19.8
40.02°C
0.984
11.941V
4.987V
3.309V
5.094V
216.925
45.78°C
115.12V
4
18.296A
4.012A
3.990A
1.573A
259.673
89.863%
1000
23.9
40.64°C
0.987
11.941V
4.986V
3.308V
5.085V
288.966
47.23°C
115.12V
5
22.988A
5.016A
4.986A
1.774A
324.974
89.544%
1337
33.2
41.35°C
0.989
11.940V
4.985V
3.307V
5.076V
362.923
48.68°C
115.11V
6
27.614A
6.020A
5.989A
1.974A
389.487
89.087%
1604
40.0
41.57°C
0.989
11.939V
4.984V
3.306V
5.066V
437.199
49.83°C
115.11V
7
32.310A
7.023A
6.986A
2.176A
454.816
88.442%
1854
40.8
42.41°C
0.989
11.938V
4.984V
3.306V
5.056V
514.251
51.10°C
115.10V
8
37.001A
8.029A
7.987A
2.379A
520.128
87.713%
2084
44.1
42.74°C
0.991
11.938V
4.983V
3.305V
5.046V
592.987
52.26°C
115.10V
9
42.096A
8.534A
8.475A
2.381A
585.051
87.005%
2087
44.1
43.54°C
0.992
11.938V
4.981V
3.304V
5.040V
672.430
53.71°C
115.10V
10
46.925A
9.039A
8.992A
2.987A
649.891
86.013%
2093
44.2
44.57°C
0.992
11.938V
4.979V
3.302V
5.023V
755.570
55.41°C
115.11V
11
52.359A
9.043A
8.995A
2.991A
714.713
85.193%
2096
44.2
46.18°C
0.993
11.937V
4.977V
3.301V
5.016V
838.932
57.53°C
115.10V
CL1
0.145A
12.000A
11.997A
0.000A
101.263
83.226%
1339
33.2
41.55°C
0.974
11.946V
4.990V
3.305V
5.112V
121.673
48.47°C
115.13V
CL2
54.015A
1.002A
0.999A
1.000A
658.197
86.754%
2094
44.2
44.32°C
0.992
11.938V
4.983V
3.310V
5.067V
758.692
55.17°C
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.618A
2.003A
1.990A
0.978A
64.803
86.115%
0
<6.0
43.61°C
0.799
11.944V
4.992V
3.312V
5.112V
75.252
38.87°C
230.28V
2
8.243A
3.007A
2.988A
1.176A
129.331
89.735%
937
19.8
39.71°C
0.901
11.942V
4.989V
3.310V
5.102V
144.126
44.83°C
230.29V
3
13.272A
3.509A
3.475A
1.375A
194.472
91.144%
945
20.8
40.60°C
0.937
11.940V
4.988V
3.309V
5.093V
213.367
46.28°C
230.30V
4
18.300A
4.012A
3.989A
1.574A
259.685
91.597%
1068
26.0
41.26°C
0.953
11.939V
4.986V
3.308V
5.084V
283.508
47.71°C
230.31V
5
22.989A
5.016A
4.988A
1.774A
324.943
91.573%
1337
33.2
41.95°C
0.963
11.938V
4.985V
3.307V
5.074V
354.845
49.33°C
230.31V
6
27.612A
6.020A
5.989A
1.975A
389.439
91.353%
1678
41.2
42.39°C
0.969
11.938V
4.984V
3.306V
5.065V
426.300
50.24°C
230.29V
7
32.304A
7.023A
6.988A
2.177A
454.752
90.969%
1915
42.8
43.47°C
0.974
11.938V
4.984V
3.306V
5.054V
499.897
52.45°C
230.28V
8
36.997A
8.029A
7.989A
2.379A
520.047
90.570%
2086
44.1
43.78°C
0.977
11.937V
4.983V
3.305V
5.045V
574.191
53.56°C
230.27V
9
42.092A
8.534A
8.476A
2.382A
584.960
90.182%
2093
44.2
44.76°C
0.979
11.937V
4.981V
3.303V
5.039V
648.647
54.96°C
230.27V
10
46.920A
9.039A
8.992A
2.988A
649.787
89.728%
2095
44.2
45.84°C
0.981
11.937V
4.979V
3.302V
5.022V
724.175
56.57°C
230.26V
11
52.356A
9.042A
8.996A
2.991A
714.632
89.281%
2098
44.2
46.05°C
0.983
11.936V
4.978V
3.301V
5.016V
800.430
57.61°C
230.26V
CL1
0.140A
12.000A
11.997A
0.000A
101.215
84.188%
1487
36.7
41.96°C
0.881
11.945V
4.991V
3.305V
5.112V
120.225
49.87°C
230.27V
CL2
54.006A
1.002A
0.998A
1.000A
657.978
90.489%
2097
44.2
45.85°C
0.981
11.936V
4.983V
3.309V
5.066V
727.136
56.95°C
230.27V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.210A
0.500A
0.481A
0.195A
19.546
71.154%
0
<6.0
0.857
11.942V
4.999V
3.318V
5.131V
27.470
115.12V
2
2.483A
1.002A
0.993A
0.390A
39.952
81.254%
0
<6.0
0.932
11.942V
4.997V
3.317V
5.125V
49.169
115.12V
3
3.688A
1.503A
1.476A
0.586A
59.442
85.068%
0
<6.0
0.958
11.943V
4.993V
3.314V
5.120V
69.876
115.12V
4
4.961A
2.004A
1.991A
0.782A
79.850
87.123%
0
<6.0
0.963
11.944V
4.991V
3.312V
5.114V
91.652
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.202A
0.500A
0.479A
0.195A
19.443
71.526%
0
<6.0
0.555
11.942V
4.999V
3.318V
5.130V
27.183
230.26V
2
2.477A
0.999A
0.995A
0.390A
39.871
82.254%
0
<6.0
0.704
11.942V
4.997V
3.317V
5.125V
48.473
230.26V
3
3.684A
1.502A
1.476A
0.586A
59.389
86.012%
0
<6.0
0.781
11.943V
4.993V
3.314V
5.120V
69.047
230.27V
4
4.959A
2.004A
1.990A
0.782A
79.819
88.071%
0
<6.0
0.838
11.943V
4.992V
3.312V
5.114V
90.630
230.28V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.4 mV
9.9 mV
12.7 mV
10.3 mV
Pass
20% Load
13.6 mV
11.4 mV
13.1 mV
10.6 mV
Pass
30% Load
14.1 mV
12.8 mV
14.5 mV
11.7 mV
Pass
40% Load
15.2 mV
13.9 mV
15.1 mV
12.2 mV
Pass
50% Load
16.9 mV
15.9 mV
15.6 mV
12.8 mV
Pass
60% Load
18.5 mV
17.1 mV
16.9 mV
14.1 mV
Pass
70% Load
20.8 mV
18.7 mV
17.6 mV
16.2 mV
Pass
80% Load
21.8 mV
20.6 mV
18.8 mV
18.3 mV
Pass
90% Load
23.4 mV
22.0 mV
19.6 mV
19.7 mV
Pass
100% Load
24.8 mV
23.3 mV
21.4 mV
18.9 mV
Pass
110% Load
36.8 mV
23.6 mV
21.3 mV
23.2 mV
Pass
Crossload 1
16.5 mV
19.3 mV
18.7 mV
10.8 mV
Pass
Crossload 2
23.3 mV
15.1 mV
15.9 mV
18.5 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.0 mV
9.6 mV
12.6 mV
9.8 mV
Pass
20% Load
13.3 mV
11.3 mV
14.4 mV
10.6 mV
Pass
30% Load
13.0 mV
12.8 mV
15.2 mV
11.5 mV
Pass
40% Load
14.3 mV
14.1 mV
14.6 mV
12.0 mV
Pass
50% Load
16.7 mV
15.7 mV
16.0 mV
12.2 mV
Pass
60% Load
17.9 mV
17.3 mV
16.7 mV
13.7 mV
Pass
70% Load
19.2 mV
19.2 mV
16.9 mV
14.6 mV
Pass
80% Load
21.3 mV
21.4 mV
19.2 mV
15.3 mV
Pass
90% Load
23.6 mV
22.7 mV
20.5 mV
16.8 mV
Pass
100% Load
34.6 mV
24.0 mV
21.0 mV
17.2 mV
Pass
110% Load
37.2 mV
24.1 mV
21.6 mV
18.1 mV
Pass
Crossload 1
23.5 mV
20.6 mV
19.4 mV
11.3 mV
Pass
Crossload 2
32.8 mV
16.2 mV
17.5 mV
16.7 mV
Pass
The results above are not used in the certification process