Thermal Control DF1202512SELN (120mm, 12V, 0.25A, Rifle Bearing Fan)
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
86.182%
Average Noise Output (>1450 Load Combinations)
32.25dBA
Average PF (>1450 Load Combinations)
0.913
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1818W
Non-Accredited
12V Ripple (Full Load)
51.42mV
5V Ripple (Full Load)
24.00mV
3.3V Ripple (Full Load)
27.41mV
5VSB Ripple (Full Load)
20.93mV
12V Load Regulation
1.11%
5V Load Regulation
2.27%
3.3V Load Regulation
2.31%
5VSB Load Regulation
3.31%
Inrush Current
67.026A
Hold-Up Time & PWR_OK Signal
11.00ms
AC Loss to PWR_OK Hold Up Time
13.20ms
PWR_OK Inactive to DC Loss Delay
-2.20ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
11
AC Loss to PWR_OK Hold Up Time (ms)
13.2
PWR_OK Inactive to DC Loss Delay (ms)
-2.2
待機電源消耗
Tables 230V
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
47.071%
0.010
5.183V
0.495
230.29V
2
0.090A
0.467
59.490%
0.015
5.181V
0.785
230.29V
3
0.550A
2.843
76.796%
0.070
5.168V
3.702
230.29V
4
1.000A
5.155
78.594%
0.118
5.154V
6.559
230.29V
5
1.500A
7.710
79.248%
0.165
5.139V
9.729
230.29V
6
3.000A
15.279
78.644%
0.266
5.093V
19.428
230.28V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.911A
2.004A
1.954A
0.973A
44.801
83.441%
0
<6.0
42.23°C
0.617
12.146V
4.985V
3.376V
5.142V
53.692
35.25°C
230.28V
2
4.800A
3.019A
2.942A
1.170A
89.290
85.287%
1114
24.6
35.91°C
0.811
12.165V
4.969V
3.364V
5.128V
104.693
43.53°C
230.28V
3
8.109A
3.529A
3.427A
1.369A
134.419
87.196%
1257
28.8
36.46°C
0.883
12.137V
4.958V
3.356V
5.115V
154.158
44.34°C
230.29V
4
11.422A
4.043A
3.943A
1.569A
179.663
87.747%
1401
31.9
36.88°C
0.919
12.122V
4.947V
3.348V
5.101V
204.750
45.15°C
230.30V
5
14.412A
5.067A
4.942A
1.770A
224.975
87.618%
1539
33.8
37.27°C
0.939
12.106V
4.934V
3.339V
5.086V
256.768
46.23°C
230.31V
6
17.342A
6.096A
5.946A
1.973A
269.503
87.372%
1535
33.8
37.75°C
0.951
12.092V
4.921V
3.330V
5.071V
308.455
47.58°C
230.32V
7
20.346A
7.133A
6.954A
2.177A
314.827
86.835%
1534
33.8
38.10°C
0.959
12.077V
4.908V
3.321V
5.055V
362.559
48.49°C
230.32V
8
23.362A
8.175A
7.969A
2.382A
360.159
86.107%
1536
33.8
38.75°C
0.965
12.060V
4.894V
3.313V
5.039V
418.271
49.63°C
230.33V
9
26.778A
8.701A
8.469A
2.387A
405.074
85.233%
1533
33.7
39.38°C
0.969
12.046V
4.885V
3.306V
5.029V
475.257
50.86°C
230.33V
10
29.940A
9.234A
9.006A
3.000A
449.891
84.100%
1530
33.7
39.74°C
0.973
12.030V
4.874V
3.298V
5.001V
534.947
51.56°C
230.37V
11
33.703A
9.245A
9.021A
3.005A
494.684
83.302%
1533
33.7
40.27°C
0.976
12.016V
4.868V
3.292V
4.994V
593.844
52.63°C
230.34V
CL1
0.143A
12.001A
12.001A
0.000A
100.697
81.507%
1529
33.7
37.12°C
0.847
12.144V
4.909V
3.337V
5.137V
123.544
46.04°C
230.40V
CL2
37.017A
1.003A
0.999A
1.000A
458.816
84.806%
1535
33.8
39.56°C
0.973
12.034V
4.932V
3.325V
5.085V
541.019
51.37°C
230.34V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.188A
0.500A
0.472A
0.193A
19.508
78.671%
0
<6.0
0.368
12.131V
5.000V
3.384V
5.173V
24.797
230.30V
2
2.441A
1.002A
0.974A
0.387A
39.941
83.716%
0
<6.0
0.577
12.146V
4.993V
3.379V
5.163V
47.710
230.33V
3
3.625A
1.504A
1.450A
0.582A
59.396
85.537%
0
<6.0
0.698
12.139V
4.987V
3.375V
5.153V
69.439
230.34V
4
4.884A
2.008A
1.956A
0.778A
79.812
86.516%
0
<6.0
0.778
12.125V
4.980V
3.371V
5.143V
92.251
230.28V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
65.9 mV
23.0 mV
15.6 mV
14.0 mV
Pass
20% Load
53.0 mV
20.3 mV
17.3 mV
13.2 mV
Pass
30% Load
46.3 mV
21.0 mV
17.1 mV
13.1 mV
Pass
40% Load
45.1 mV
20.9 mV
17.2 mV
13.2 mV
Pass
50% Load
44.1 mV
20.9 mV
18.9 mV
13.9 mV
Pass
60% Load
48.8 mV
21.3 mV
20.4 mV
14.9 mV
Pass
70% Load
45.8 mV
23.8 mV
21.4 mV
14.9 mV
Pass
80% Load
42.5 mV
22.1 mV
25.0 mV
16.7 mV
Pass
90% Load
42.4 mV
22.0 mV
25.2 mV
17.2 mV
Pass
100% Load
51.4 mV
24.0 mV
27.4 mV
20.9 mV
Pass
110% Load
52.9 mV
24.7 mV
28.4 mV
21.3 mV
Pass
Crossload 1
52.1 mV
22.7 mV
30.8 mV
14.4 mV
Pass
Crossload 2
49.1 mV
21.7 mV
18.1 mV
17.0 mV
Pass
The results above are not used in the certification process