Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan )
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
87.618%
Average Noise Output (>1450 Load Combinations)
37.93dBA
Average PF (>1450 Load Combinations)
0.911
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1773W
Non-Accredited
12V Ripple (Full Load)
46.66mV
5V Ripple (Full Load)
28.12mV
3.3V Ripple (Full Load)
28.65mV
5VSB Ripple (Full Load)
35.55mV
12V Load Regulation
1.34%
5V Load Regulation
2.61%
3.3V Load Regulation
2.79%
5VSB Load Regulation
3.40%
Inrush Current
Too low to detect
Hold-Up Time & PWR_OK Signal
14.80ms
AC Loss to PWR_OK Hold Up Time
51.20ms
PWR_OK Inactive to DC Loss Delay
-36.40ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
14.80
AC Loss to PWR_OK Hold Up Time (ms)
51.20
PWR_OK Inactive to DC Loss Delay (ms)
-36.40
Stromverbrauch im Ruhezustand
Tables 230V
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.046A
0.234
47.465%
0.139
5.136V
0.493
230.26V
2
0.090A
0.467
59.642%
0.015
5.183V
0.783
230.26V
3
0.550A
2.843
76.651%
0.070
5.168V
3.709
230.26V
4
1.000A
5.154
78.269%
0.119
5.153V
6.585
230.26V
5
1.500A
7.706
78.923%
0.169
5.137V
9.764
230.26V
6
3.000A
15.263
78.614%
0.277
5.088V
19.415
230.26V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.170A
2.012A
1.982A
0.972A
60.017
85.543%
0
<6.0
41.58°C
0.652
12.120V
4.971V
3.328V
5.142V
70.160
34.68°C
230.24V
2
7.361A
3.025A
2.983A
1.170A
119.713
88.060%
0
<6.0
42.85°C
0.812
12.067V
4.956V
3.318V
5.127V
135.945
35.67°C
230.24V
3
11.902A
3.542A
3.475A
1.369A
179.619
89.168%
1083
23.2
35.91°C
0.879
12.067V
4.941V
3.308V
5.114V
201.439
43.55°C
230.24V
4
16.467A
4.058A
3.999A
1.569A
239.623
89.615%
1309
28.8
36.13°C
0.914
12.050V
4.929V
3.299V
5.099V
267.391
44.04°C
230.24V
5
20.709A
5.089A
5.016A
1.770A
299.716
89.520%
1504
32.6
36.54°C
0.937
12.034V
4.914V
3.289V
5.084V
334.805
45.22°C
230.24V
6
24.962A
6.125A
6.039A
1.973A
359.823
89.063%
1939
40.0
36.86°C
0.950
12.019V
4.899V
3.278V
5.069V
404.008
46.52°C
230.24V
7
29.192A
7.169A
7.068A
2.178A
419.538
88.570%
2122
42.4
37.44°C
0.958
12.004V
4.884V
3.268V
5.053V
473.678
47.43°C
230.24V
8
33.502A
8.219A
8.105A
2.383A
480.033
87.952%
2340
44.2
37.69°C
0.963
11.988V
4.868V
3.257V
5.037V
545.791
48.57°C
230.24V
9
38.156A
8.752A
8.618A
2.387A
539.344
87.322%
2396
45.0
38.24°C
0.968
11.973V
4.857V
3.248V
5.028V
617.653
49.54°C
230.24V
10
42.653A
9.288A
9.171A
3.002A
599.754
86.562%
2393
44.6
39.19°C
0.971
11.958V
4.846V
3.238V
4.998V
692.861
50.73°C
230.23V
11
47.731A
9.300A
9.192A
3.007A
659.765
85.718%
2404
45.1
40.34°C
0.973
11.943V
4.840V
3.231V
4.989V
769.691
52.55°C
230.24V
CL1
0.137A
14.002A
13.997A
0.000A
115.657
80.688%
2014
41.1
36.32°C
0.828
12.083V
4.863V
3.280V
5.144V
143.338
45.34°C
230.23V
CL2
49.004A
1.002A
1.000A
1.000A
599.760
87.465%
2396
45.0
39.32°C
0.971
11.968V
4.919V
3.270V
5.080V
685.718
51.01°C
230.23V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.192A
0.501A
0.479A
0.193A
19.510
78.650%
0
<6.0
0.348
12.093V
4.985V
3.337V
5.176V
24.806
230.24V
2
2.449A
1.003A
0.988A
0.387A
39.945
84.529%
0
<6.0
0.538
12.111V
4.979V
3.333V
5.166V
47.256
230.24V
3
3.632A
1.508A
1.471A
0.582A
59.420
86.132%
0
<6.0
0.648
12.120V
4.974V
3.330V
5.157V
68.987
230.24V
4
4.896A
2.013A
1.983A
0.777A
79.823
87.030%
0
<6.0
0.725
12.097V
4.968V
3.326V
5.147V
91.719
230.24V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
84.8 mV
20.9 mV
15.0 mV
20.9 mV
Pass
20% Load
91.9 mV
23.8 mV
17.4 mV
21.9 mV
Pass
30% Load
30.7 mV
21.6 mV
18.2 mV
22.9 mV
Pass
40% Load
29.6 mV
23.4 mV
19.9 mV
24.6 mV
Pass
50% Load
28.2 mV
23.2 mV
20.7 mV
25.2 mV
Pass
60% Load
28.5 mV
24.0 mV
22.9 mV
26.5 mV
Pass
70% Load
29.1 mV
23.8 mV
23.9 mV
27.1 mV
Pass
80% Load
28.9 mV
24.2 mV
25.3 mV
30.5 mV
Pass
90% Load
29.0 mV
25.2 mV
27.4 mV
31.4 mV
Pass
100% Load
46.7 mV
28.1 mV
28.7 mV
35.6 mV
Pass
110% Load
47.0 mV
27.8 mV
29.6 mV
36.6 mV
Pass
Crossload 1
92.4 mV
28.3 mV
29.9 mV
23.5 mV
Pass
Crossload 2
44.8 mV
27.0 mV
22.9 mV
29.9 mV
Pass
The results above are not used in the certification process
Cooler Master MWE 600
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern