Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan )
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
87.274%
Average Noise Output (>1450 Load Combinations)
37.41dBA
Average PF (>1450 Load Combinations)
0.917
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1788W
Non-Accredited
12V Ripple (Full Load)
44.67mV
5V Ripple (Full Load)
29.25mV
3.3V Ripple (Full Load)
28.32mV
5VSB Ripple (Full Load)
32.03mV
12V Load Regulation
1.46%
5V Load Regulation
2.96%
3.3V Load Regulation
2.94%
5VSB Load Regulation
3.73%
Inrush Current
65.413A
Hold-Up Time & Power Ok Signal
28.00ms
AC Loss to PWR_OK Hold Up Time
72.00ms
PWR_OK Inactive to DC Loss Delay
-44.00ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
129.90%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
28.0
AC Loss to PWR_OK Hold Up Time (ms)
72.0
PWR_OK Inactive to DC Loss Delay (ms)
-44.0
待機電源消耗
Tables 230V
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
47.262%
0.010
5.179V
0.493
230.33V
2
0.090A
0.466
59.744%
0.015
5.178V
0.780
230.33V
3
0.550A
2.841
77.390%
0.069
5.164V
3.671
230.31V
4
1.000A
5.151
79.124%
0.119
5.150V
6.510
230.32V
5
1.500A
7.703
79.716%
0.168
5.134V
9.663
230.32V
6
3.000A
15.261
79.089%
0.277
5.087V
19.296
230.32V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.960A
2.019A
1.982A
0.974A
69.611
77.066%
1195
26.3
34.19°C
0.720
12.125V
4.954V
3.326V
5.136V
90.327
40.69°C
230.30V
2
8.987A
3.038A
2.983A
1.172A
139.697
85.985%
1325
29.2
34.56°C
0.840
12.107V
4.937V
3.316V
5.120V
162.467
41.64°C
230.30V
3
14.373A
3.554A
3.475A
1.372A
209.595
89.646%
1233
27.6
35.12°C
0.894
12.078V
4.925V
3.307V
5.104V
233.802
42.67°C
230.30V
4
19.776A
4.072A
4.001A
1.573A
279.621
89.929%
1466
32.7
35.67°C
0.924
12.056V
4.912V
3.298V
5.088V
310.936
43.65°C
230.30V
5
24.853A
5.107A
5.017A
1.775A
349.721
89.698%
1822
38.1
36.21°C
0.941
12.040V
4.895V
3.287V
5.071V
389.888
44.56°C
230.30V
6
29.952A
6.150A
6.043A
1.979A
419.848
89.344%
1949
40.2
36.67°C
0.952
12.021V
4.878V
3.276V
5.053V
469.922
45.68°C
230.30V
7
35.064A
7.200A
7.077A
2.185A
489.980
88.758%
2167
42.7
37.28°C
0.959
12.003V
4.861V
3.265V
5.035V
552.038
47.07°C
230.30V
8
40.192A
8.259A
8.115A
2.392A
560.106
88.054%
2334
44.2
37.97°C
0.965
11.985V
4.844V
3.253V
5.017V
636.096
48.51°C
230.30V
9
45.729A
8.798A
8.632A
2.398A
629.841
87.352%
2444
45.9
38.65°C
0.969
11.969V
4.831V
3.244V
5.006V
721.040
49.76°C
230.31V
10
51.057A
9.343A
9.185A
3.016A
699.896
86.471%
2446
45.9
39.82°C
0.971
11.951V
4.817V
3.234V
4.975V
809.398
51.31°C
230.32V
11
56.995A
9.361A
9.208A
3.023A
769.942
85.394%
2443
45.9
40.42°C
0.972
11.935V
4.808V
3.225V
4.963V
901.631
52.76°C
230.32V
CL1
0.147A
14.001A
14.001A
0.000A
115.761
77.104%
2251
43.0
36.55°C
0.822
12.102V
4.855V
3.286V
5.131V
150.136
44.50°C
230.32V
CL2
58.017A
1.003A
0.999A
1.000A
707.102
87.228%
2445
45.9
39.89°C
0.972
11.960V
4.888V
3.262V
5.057V
810.637
51.24°C
230.34V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.192A
0.501A
0.478A
0.194A
19.532
78.003%
0
<6.0
0.364
12.115V
4.975V
3.338V
5.170V
25.040
230.30V
2
2.444A
1.006A
0.986A
0.388A
39.925
84.159%
0
<6.0
0.547
12.126V
4.970V
3.334V
5.160V
47.440
230.31V
3
3.626A
1.513A
1.469A
0.583A
59.369
74.853%
1113
24.0
0.689
12.127V
4.959V
3.329V
5.151V
79.314
230.31V
4
4.884A
2.019A
1.983A
0.778A
79.797
78.817%
1184
25.9
0.747
12.122V
4.953V
3.325V
5.141V
101.243
230.30V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
15.6 mV
21.4 mV
16.4 mV
18.9 mV
Pass
20% Load
18.0 mV
20.9 mV
16.2 mV
19.9 mV
Pass
30% Load
34.2 mV
22.3 mV
17.0 mV
21.5 mV
Pass
40% Load
32.0 mV
22.6 mV
17.7 mV
22.8 mV
Pass
50% Load
29.0 mV
22.3 mV
17.5 mV
22.5 mV
Pass
60% Load
27.8 mV
22.5 mV
21.0 mV
24.7 mV
Pass
70% Load
27.0 mV
24.1 mV
21.5 mV
25.7 mV
Pass
80% Load
27.8 mV
24.6 mV
24.9 mV
26.4 mV
Pass
90% Load
28.4 mV
24.3 mV
26.5 mV
26.3 mV
Pass
100% Load
44.7 mV
29.3 mV
28.3 mV
32.0 mV
Pass
110% Load
48.0 mV
27.9 mV
28.0 mV
32.9 mV
Pass
Crossload 1
42.5 mV
27.0 mV
32.4 mV
19.9 mV
Pass
Crossload 2
44.7 mV
26.9 mV
18.2 mV
29.5 mV
Pass
The results above are not used in the certification process