Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan )
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Accredited
Average Efficiency (>1450 load combinations)
87.201%
Average Noise Output (>1450 Load Combinations)
37.06dBA
Average PF (>1450 Load Combinations)
0.927
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1856W
Non-Accredited
12V Ripple (Full Load)
40.19mV
5V Ripple (Full Load)
26.26mV
3.3V Ripple (Full Load)
23.71mV
5VSB Ripple (Full Load)
41.38mV
12V Load Regulation
1.71%
5V Load Regulation
3.12%
3.3V Load Regulation
3.66%
5VSB Load Regulation
3.99%
Inrush Current
88.906A
Hold-Up Time & PWR_OK Signal
22.00ms
AC Loss to PWR_OK Hold Up Time
70.00ms
PWR_OK Inactive to DC Loss Delay
-48.00ms
OPP (0.00°C / 0.00°C)
120.15%
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
22
AC Loss to PWR_OK Hold Up Time (ms)
70
PWR_OK Inactive to DC Loss Delay (ms)
-48
待機電源消耗
Tables 230V
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
46.600%
0.009
5.171V
0.500
230.28V
2
0.090A
0.466
59.363%
0.014
5.170V
0.785
230.26V
3
0.550A
2.837
77.051%
0.066
5.156V
3.682
230.26V
4
1.000A
5.143
78.856%
0.114
5.143V
6.522
230.27V
5
1.500A
7.692
79.537%
0.161
5.128V
9.671
230.27V
6
3.000A
15.246
79.064%
0.267
5.082V
19.283
230.28V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.370A
2.006A
1.965A
0.975A
74.490
77.205%
1077
23.2
34.51°C
0.679
12.102V
4.988V
3.358V
5.129V
96.484
40.29°C
230.29V
2
9.807A
3.019A
2.959A
1.174A
149.381
87.438%
1169
25.7
35.26°C
0.839
12.081V
4.970V
3.345V
5.112V
170.842
41.37°C
230.29V
3
15.674A
3.531A
3.447A
1.374A
224.900
89.912%
1157
25.4
35.99°C
0.915
12.052V
4.957V
3.334V
5.095V
250.134
42.50°C
230.29V
4
21.493A
4.047A
3.973A
1.576A
299.680
90.055%
1340
30.2
36.56°C
0.941
12.026V
4.943V
3.322V
5.077V
332.773
43.44°C
230.29V
5
26.993A
5.077A
4.988A
1.779A
374.592
89.717%
1772
38.2
36.95°C
0.949
12.006V
4.926V
3.309V
5.059V
417.526
44.56°C
230.29V
6
32.518A
6.112A
6.009A
1.985A
449.497
89.183%
1893
38.4
37.21°C
0.967
11.984V
4.908V
3.295V
5.040V
504.017
45.49°C
230.29V
7
38.097A
7.161A
7.040A
2.192A
524.831
88.483%
2106
41.5
37.90°C
0.975
11.962V
4.889V
3.281V
5.021V
593.144
46.64°C
230.29V
8
43.692A
8.214A
8.080A
2.400A
600.133
87.682%
2358
44.3
38.28°C
0.978
11.941V
4.871V
3.267V
5.000V
684.443
47.49°C
230.29V
9
49.678A
8.753A
8.602A
2.407A
674.680
86.829%
2406
45.1
39.09°C
0.980
11.920V
4.857V
3.255V
4.988V
777.024
48.59°C
230.28V
10
55.487A
9.296A
9.159A
3.028A
749.892
85.725%
2407
45.1
39.44°C
0.978
11.898V
4.842V
3.242V
4.955V
874.762
49.81°C
230.29V
11
61.923A
9.316A
9.191A
3.036A
825.123
84.431%
2400
45.1
39.88°C
0.976
11.876V
4.832V
3.232V
4.942V
977.277
51.11°C
230.29V
CL1
0.146A
14.004A
13.999A
0.000A
116.578
77.537%
1944
40.1
36.61°C
0.787
12.074V
4.887V
3.313V
5.126V
150.352
44.45°C
230.29V
CL2
62.011A
1.002A
1.000A
1.000A
751.724
86.546%
2414
45.3
39.35°C
0.979
11.909V
4.914V
3.275V
5.036V
868.585
49.36°C
230.29V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.196A
0.499A
0.475A
0.194A
19.533
78.626%
0
<6.0
0.335
12.065V
5.010V
3.373V
5.163V
24.843
230.26V
2
2.458A
0.998A
0.980A
0.388A
39.961
84.525%
0
<6.0
0.531
12.070V
5.003V
3.368V
5.154V
47.277
230.27V
3
3.639A
1.502A
1.457A
0.583A
59.451
74.373%
928
19.4
0.645
12.105V
4.994V
3.363V
5.144V
79.936
230.28V
4
4.899A
2.006A
1.963A
0.779A
79.874
78.735%
1065
23.0
0.699
12.100V
4.987V
3.358V
5.134V
101.446
230.28V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.5 mV
15.9 mV
10.6 mV
20.7 mV
Pass
20% Load
13.0 mV
16.5 mV
12.6 mV
22.5 mV
Pass
30% Load
33.5 mV
16.6 mV
13.9 mV
25.6 mV
Pass
40% Load
30.7 mV
17.9 mV
14.7 mV
26.9 mV
Pass
50% Load
28.8 mV
19.5 mV
15.4 mV
29.1 mV
Pass
60% Load
27.8 mV
19.3 mV
16.7 mV
30.6 mV
Pass
70% Load
25.8 mV
20.0 mV
19.3 mV
32.7 mV
Pass
80% Load
34.2 mV
22.4 mV
20.9 mV
33.5 mV
Pass
90% Load
27.4 mV
24.3 mV
21.6 mV
33.7 mV
Pass
100% Load
40.2 mV
26.3 mV
23.7 mV
41.4 mV
Pass
110% Load
42.0 mV
28.2 mV
24.7 mV
44.2 mV
Pass
Crossload 1
18.1 mV
26.9 mV
22.1 mV
22.9 mV
Pass
Crossload 2
38.8 mV
24.0 mV
18.0 mV
40.5 mV
Pass
The results above are not used in the certification process