Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan )
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
温度范围 (°C /°F)
28-32 / 82.4-89.6
符合ErP Lot3/6规范
✓
符合(EU) No 617/2013规范
✓
Performance Summary
Accredited
平均效率 (>1450 load combinations)
85.672%
Average Noise Output (>1450 Load Combinations)
42.09dBA
PF平均值 (>1450 Load Combinations)
0.972
Efficiency With 10W (≤500W) or 2% (>500W) Load
72.857%
待机功率耗损
0.0765W
Non-Accredited
12V Ripple (Full Load)
36.15mV
5V Ripple (Full Load)
21.90mV
3.3V Ripple (Full Load)
24.66mV
5VSB Ripple (Full Load)
23.71mV
12V Load Regulation
1.08%
5V Load Regulation
2.12%
3.3V Load Regulation
2.16%
5VSB Load Regulation
2.82%
Inrush Current
33.155A
Accredited
平均效率 (>1450 load combinations)
87.845%
Average Noise Output (>1450 Load Combinations)
42.23dBA
PF平均值 (>1450 Load Combinations)
0.907
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
待机功率耗损
0.1902W
Non-Accredited
12V Ripple (Full Load)
37.07mV
5V Ripple (Full Load)
23.05mV
3.3V Ripple (Full Load)
25.12mV
5VSB Ripple (Full Load)
23.88mV
12V Load Regulation
1.11%
5V Load Regulation
2.10%
3.3V Load Regulation
2.16%
5VSB Load Regulation
2.80%
Inrush Current
64.338A
保持时间 & PG信号
22.40ms
AC Loss to PWR_OK Hold Up Time
21.00ms
PWR_OK Inactive to DC Loss Delay
1.40ms
OPP (0.00°C / 0.00°C)
124.39%
-
保持时间 & PG信号
Hold-Up Time (ms)
22.4
AC Loss to PWR_OK Hold Up Time (ms)
21
PWR_OK Inactive to DC Loss Delay (ms)
1.4
待机电源
Tables
Graphs
转换效率图表
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
噪音值图表
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC)
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.234
60.154%
0.025
5.188V
0.389
115.13V
2
0.090A
0.467
69.288%
0.043
5.187V
0.674
115.13V
3
0.550A
2.848
78.696%
0.203
5.177V
3.619
115.12V
4
1.000A
5.167
79.346%
0.304
5.166V
6.512
115.12V
5
1.500A
7.733
79.541%
0.369
5.154V
9.722
115.12V
6
3.000A
15.356
77.462%
0.447
5.118V
19.824
115.12V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.234
46.337%
0.010
5.188V
0.505
230.30V
2
0.090A
0.467
58.742%
0.016
5.187V
0.795
230.30V
3
0.550A
2.848
76.828%
0.070
5.177V
3.707
230.33V
4
1.000A
5.167
78.765%
0.120
5.166V
6.560
230.31V
5
1.500A
7.733
79.500%
0.169
5.154V
9.727
230.31V
6
3.000A
15.356
79.261%
0.276
5.119V
19.374
230.31V
Protection Features
Supplementary Tests (For Reference)
10-110%负载测试
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
4.365A
2.019A
1.981A
0.970A
74.479
75.170%
1434
31.8
34.35°C
0.963
12.113V
4.955V
3.331V
5.157V
99.081
39.76°C
115.12V
2
9.788A
3.035A
2.978A
1.167A
149.347
85.065%
1845
38.3
35.18°C
0.949
12.101V
4.943V
3.323V
5.144V
175.569
40.87°C
115.11V
3
15.624A
3.546A
3.465A
1.364A
224.870
88.301%
1761
38.0
35.56°C
0.956
12.089V
4.934V
3.317V
5.133V
254.663
41.99°C
115.11V
4
21.430A
4.062A
3.988A
1.562A
299.650
88.569%
1944
40.1
35.72°C
0.969
12.060V
4.925V
3.310V
5.121V
338.325
42.61°C
115.11V
5
26.899A
5.090A
4.995A
1.762A
374.580
88.289%
2162
42.6
36.18°C
0.977
12.048V
4.913V
3.302V
5.108V
424.266
43.63°C
115.10V
6
32.383A
6.122A
6.011A
1.963A
449.509
87.756%
2314
44.0
36.54°C
0.981
12.034V
4.902V
3.294V
5.095V
512.226
45.24°C
115.10V
7
37.907A
7.159A
7.030A
2.165A
524.829
86.998%
2469
46.0
37.29°C
0.985
12.022V
4.890V
3.286V
5.082V
603.268
46.35°C
115.10V
8
43.446A
8.201A
8.056A
2.368A
600.158
86.112%
2469
46.0
37.93°C
0.987
12.009V
4.878V
3.278V
5.069V
696.951
47.39°C
115.09V
9
49.361A
8.730A
8.560A
2.372A
674.692
85.079%
2467
46.0
38.63°C
0.988
11.997V
4.869V
3.271V
5.060V
793.018
49.13°C
115.09V
10
55.087A
9.262A
9.101A
2.979A
749.930
83.670%
2468
46.0
39.36°C
0.990
11.985V
4.859V
3.264V
5.036V
896.291
50.63°C
115.11V
11
61.431A
9.276A
9.117A
2.983A
825.164
82.157%
2469
46.0
40.18°C
0.992
11.972V
4.852V
3.258V
5.029V
1004.371
52.57°C
115.12V
CL1
0.149A
14.000A
14.000A
0.000A
116.448
76.782%
2461
45.9
36.03°C
0.955
12.097V
4.890V
3.299V
5.153V
151.660
43.56°C
115.12V
CL2
62.523A
1.002A
1.001A
1.000A
763.013
84.112%
2468
46.0
39.53°C
0.990
11.991V
4.904V
3.285V
5.098V
907.143
50.70°C
115.09V
The results above are not used in the certification process
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
4.368A
2.019A
1.981A
0.970A
74.509
76.434%
1428
31.6
34.10°C
0.734
12.112V
4.955V
3.331V
5.156V
97.482
40.15°C
230.31V
2
9.793A
3.036A
2.977A
1.167A
149.398
86.484%
1875
38.4
34.86°C
0.850
12.100V
4.943V
3.323V
5.144V
172.746
41.33°C
230.32V
3
15.630A
3.548A
3.467A
1.364A
224.922
89.851%
1763
38.1
35.00°C
0.886
12.087V
4.934V
3.316V
5.132V
250.328
42.08°C
230.32V
4
21.437A
4.064A
3.987A
1.563A
299.724
90.260%
1986
40.8
35.74°C
0.915
12.059V
4.925V
3.310V
5.120V
332.066
43.47°C
230.33V
5
26.913A
5.090A
4.998A
1.762A
374.677
90.195%
2156
42.7
36.03°C
0.930
12.045V
4.913V
3.302V
5.107V
415.410
44.55°C
230.34V
6
32.394A
6.123A
6.010A
1.963A
449.603
89.845%
2394
44.6
36.61°C
0.938
12.033V
4.901V
3.294V
5.094V
500.420
45.62°C
230.34V
7
37.925A
7.161A
7.033A
2.165A
524.935
89.369%
2469
46.0
37.16°C
0.944
12.019V
4.889V
3.285V
5.081V
587.379
46.95°C
230.34V
8
43.466A
8.205A
8.055A
2.369A
600.271
88.791%
2467
46.0
37.53°C
0.951
12.006V
4.877V
3.277V
5.068V
676.051
47.88°C
230.35V
9
49.382A
8.733A
8.561A
2.372A
674.803
88.107%
2460
45.9
38.29°C
0.956
11.994V
4.868V
3.271V
5.059V
765.889
49.24°C
230.35V
10
55.108A
9.265A
9.103A
2.979A
750.017
87.154%
2466
46.0
39.74°C
0.960
11.982V
4.858V
3.263V
5.035V
860.564
51.26°C
230.35V
11
61.449A
9.276A
9.119A
2.984A
825.246
86.189%
2467
46.0
40.23°C
0.963
11.970V
4.851V
3.257V
5.028V
957.482
52.44°C
230.34V
CL1
0.152A
14.002A
14.003A
0.000A
116.504
78.120%
2458
45.9
36.26°C
0.831
12.096V
4.890V
3.299V
5.153V
149.134
44.47°C
230.34V
CL2
62.530A
1.003A
1.001A
1.000A
762.912
87.656%
2468
46.0
39.99°C
0.960
11.988V
4.903V
3.284V
5.097V
870.348
51.31°C
230.34V
The results above are not used in the certification process
20-80瓦负载测试
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.197A
0.504A
0.478A
0.193A
19.562
76.390%
0
<6.0
0.732
12.083V
4.968V
3.339V
5.182V
25.608
115.13V
2
2.456A
1.008A
0.987A
0.387A
39.984
82.251%
0
<6.0
0.890
12.087V
4.964V
3.336V
5.175V
48.612
115.12V
3
3.638A
1.512A
1.470A
0.581A
59.478
72.990%
1295
28.6
0.938
12.116V
4.959V
3.333V
5.168V
81.488
115.12V
4
4.891A
2.018A
1.979A
0.775A
79.826
76.362%
1386
30.5
0.965
12.112V
4.954V
3.330V
5.160V
104.536
115.12V
The results above are not used in the certification process
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.202A
0.504A
0.478A
0.193A
19.631
76.669%
0
<6.0
0.354
12.088V
4.970V
3.340V
5.181V
25.605
230.33V
2
2.460A
1.008A
0.987A
0.387A
40.041
83.523%
0
<6.0
0.528
12.090V
4.965V
3.337V
5.174V
47.940
230.33V
3
3.642A
1.514A
1.470A
0.581A
59.533
74.029%
1433
31.7
0.679
12.115V
4.959V
3.333V
5.167V
80.418
230.33V
4
4.896A
2.020A
1.979A
0.775A
79.892
77.708%
1450
32.3
0.746
12.111V
4.954V
3.330V
5.160V
102.810
230.33V
The results above are not used in the certification process
纹波测量
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.6 mV
18.9 mV
18.8 mV
17.7 mV
Pass
20% Load
15.1 mV
19.3 mV
14.1 mV
16.7 mV
Pass
30% Load
27.7 mV
19.1 mV
15.2 mV
15.3 mV
Pass
40% Load
23.4 mV
19.1 mV
15.7 mV
15.2 mV
Pass
50% Load
22.7 mV
19.7 mV
17.0 mV
15.5 mV
Pass
60% Load
31.0 mV
22.2 mV
19.3 mV
18.5 mV
Pass
70% Load
22.0 mV
19.9 mV
19.6 mV
18.0 mV
Pass
80% Load
28.2 mV
20.9 mV
24.0 mV
19.8 mV
Pass
90% Load
23.8 mV
20.7 mV
24.7 mV
20.8 mV
Pass
100% Load
36.2 mV
21.9 mV
24.7 mV
23.7 mV
Pass
110% Load
35.2 mV
22.4 mV
25.6 mV
23.9 mV
Pass
Crossload 1
18.9 mV
26.0 mV
29.1 mV
16.5 mV
Pass
Crossload 2
33.2 mV
21.5 mV
16.1 mV
20.6 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.2 mV
19.0 mV
13.4 mV
16.9 mV
Pass
20% Load
14.9 mV
19.1 mV
14.4 mV
15.3 mV
Pass
30% Load
29.9 mV
19.9 mV
14.8 mV
14.9 mV
Pass
40% Load
25.5 mV
19.1 mV
15.6 mV
14.6 mV
Pass
50% Load
22.8 mV
19.7 mV
16.1 mV
14.8 mV
Pass
60% Load
22.0 mV
19.4 mV
19.0 mV
16.4 mV
Pass
70% Load
21.8 mV
20.2 mV
18.7 mV
16.6 mV
Pass
80% Load
30.7 mV
21.8 mV
22.4 mV
18.5 mV
Pass
90% Load
21.2 mV
20.6 mV
23.3 mV
18.7 mV
Pass
100% Load
37.1 mV
23.1 mV
25.1 mV
23.9 mV
Pass
110% Load
36.0 mV
22.6 mV
27.1 mV
24.2 mV
Pass
Crossload 1
17.6 mV
26.2 mV
28.5 mV
16.7 mV
Pass
Crossload 2
34.0 mV
21.6 mV
16.3 mV
19.1 mV
Pass
The results above are not used in the certification process