Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan )
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
温度范围 (°C /°F)
28-32 / 82.4-89.6
符合ErP Lot3/6规范
✓
符合(EU) No 617/2013规范
✓
Performance Summary
Accredited
平均效率 (>1450 load combinations)
86.077%
Average Noise Output (>1450 Load Combinations)
38.27dBA
PF平均值 (>1450 Load Combinations)
0.976
Efficiency With 10W (≤500W) or 2% (>500W) Load
72.353%
待机功率耗损
0.0804W
Non-Accredited
12V Ripple (Full Load)
33.40mV
5V Ripple (Full Load)
19.51mV
3.3V Ripple (Full Load)
17.19mV
5VSB Ripple (Full Load)
28.39mV
12V Load Regulation
0.97%
5V Load Regulation
1.86%
3.3V Load Regulation
2.07%
5VSB Load Regulation
2.70%
Inrush Current
66.030A
Accredited
平均效率 (>1450 load combinations)
88.392%
Average Noise Output (>1450 Load Combinations)
38.95dBA
PF平均值 (>1450 Load Combinations)
0.905
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
待机功率耗损
0.2063W
Non-Accredited
12V Ripple (Full Load)
33.26mV
5V Ripple (Full Load)
19.81mV
3.3V Ripple (Full Load)
16.75mV
5VSB Ripple (Full Load)
27.45mV
12V Load Regulation
0.97%
5V Load Regulation
1.84%
3.3V Load Regulation
2.04%
5VSB Load Regulation
2.63%
Inrush Current
95.150A
保持时间 & PG信号
22.40ms
AC Loss to PWR_OK Hold Up Time
20.40ms
PWR_OK Inactive to DC Loss Delay
2.00ms
OPP (0.00°C / 0.00°C)
-
-
保持时间 & PG信号
Hold-Up Time (ms)
22.4
AC Loss to PWR_OK Hold Up Time (ms)
20.4
PWR_OK Inactive to DC Loss Delay (ms)
2
待机电源
Tables
Graphs
转换效率图表
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
噪音值图表
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC)
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.234
59.542%
0.025
5.188V
0.393
115.15V
2
0.090A
0.468
68.925%
0.043
5.187V
0.679
115.15V
3
0.550A
2.848
78.457%
0.203
5.176V
3.630
115.15V
4
1.000A
5.166
79.209%
0.305
5.165V
6.522
115.15V
5
1.500A
7.730
79.347%
0.372
5.152V
9.742
115.16V
6
3.000A
15.343
77.267%
0.453
5.114V
19.857
115.16V
测试 #
5VSB
DC/AC (瓦)
效率
PF/AC 电压
1
0.045A
0.234
44.914%
0.010
5.188V
0.521
230.29V
2
0.090A
0.468
57.707%
0.015
5.187V
0.811
230.29V
3
0.550A
2.848
76.354%
0.069
5.176V
3.730
230.33V
4
1.000A
5.166
78.427%
0.117
5.165V
6.587
230.32V
5
1.500A
7.729
79.231%
0.165
5.152V
9.755
230.33V
6
3.000A
15.343
78.888%
0.272
5.114V
19.449
230.30V
Protection Features
Supplementary Tests (For Reference)
10-110%负载测试
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
3.569A
2.004A
1.955A
0.970A
64.893
77.606%
1115
24.1
35.08°C
0.912
12.131V
4.991V
3.373V
5.156V
83.618
40.81°C
115.12V
2
8.126A
3.012A
2.939A
1.166A
129.381
86.115%
1225
27.2
35.86°C
0.958
12.120V
4.981V
3.366V
5.145V
150.242
42.13°C
115.12V
3
13.105A
3.519A
3.425A
1.364A
194.475
88.026%
1297
28.7
36.49°C
0.965
12.092V
4.973V
3.360V
5.133V
220.929
43.17°C
115.11V
4
18.086A
4.030A
3.938A
1.562A
259.692
88.363%
1443
32.1
36.80°C
0.974
12.080V
4.965V
3.353V
5.122V
293.892
44.17°C
115.11V
5
22.742A
5.046A
4.932A
1.762A
324.972
88.067%
1887
38.4
37.40°C
0.983
12.069V
4.954V
3.345V
5.110V
369.005
45.28°C
115.11V
6
27.342A
6.070A
5.932A
1.962A
389.495
87.601%
2095
41.2
37.86°C
0.987
12.058V
4.944V
3.337V
5.097V
444.626
46.36°C
115.11V
7
32.018A
7.098A
6.938A
2.164A
454.804
86.931%
2406
45.1
38.51°C
0.989
12.046V
4.933V
3.329V
5.085V
523.176
47.65°C
115.11V
8
36.698A
8.129A
7.948A
2.367A
520.110
86.131%
2455
45.9
38.88°C
0.991
12.036V
4.922V
3.321V
5.072V
603.860
48.74°C
115.11V
9
41.788A
8.649A
8.444A
2.370A
585.014
85.290%
2454
45.9
39.46°C
0.992
12.025V
4.915V
3.316V
5.065V
685.913
49.83°C
115.10V
10
46.624A
9.172A
8.977A
2.976A
649.858
84.194%
2453
45.9
39.85°C
0.993
12.014V
4.907V
3.309V
5.042V
771.858
50.78°C
115.10V
11
52.067A
9.183A
8.991A
2.980A
714.680
82.981%
2452
45.9
40.28°C
0.993
12.003V
4.902V
3.303V
5.036V
861.260
51.78°C
115.10V
CL1
0.139A
14.001A
13.999A
0.000A
117.437
78.674%
2185
42.8
37.01°C
0.956
12.109V
4.924V
3.344V
5.159V
149.271
45.89°C
115.12V
CL2
54.005A
1.002A
1.002A
1.000A
662.490
84.869%
2457
45.9
39.70°C
0.993
12.019V
4.955V
3.330V
5.103V
780.603
50.81°C
115.10V
The results above are not used in the certification process
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
温度(输入/输出)
PF/AC 电压
1
3.565A
2.004A
1.955A
0.970A
64.841
79.060%
1047
22.1
34.01°C
0.649
12.130V
4.991V
3.373V
5.156V
82.015
39.74°C
230.25V
2
8.122A
3.014A
2.943A
2.942A
138.335
87.198%
1064
22.8
34.41°C
0.832
12.119V
4.978V
3.363V
5.100V
158.645
40.49°C
230.24V
3
13.103A
3.520A
3.422A
1.364A
194.429
89.978%
1131
24.9
35.24°C
0.870
12.091V
4.973V
3.359V
5.133V
216.085
41.79°C
230.25V
4
18.085A
4.027A
3.937A
1.562A
259.662
90.432%
1340
29.9
35.71°C
0.907
12.080V
4.965V
3.353V
5.122V
287.134
42.67°C
230.25V
5
22.742A
5.048A
4.931A
1.761A
324.951
90.386%
1609
33.1
36.04°C
0.935
12.068V
4.954V
3.345V
5.110V
359.515
43.82°C
230.25V
6
27.344A
6.071A
5.933A
1.962A
389.468
90.067%
2007
41.2
36.98°C
0.945
12.056V
4.943V
3.337V
5.098V
432.421
45.23°C
230.26V
7
32.020A
7.098A
6.940A
2.163A
454.792
89.653%
2212
42.8
37.16°C
0.953
12.045V
4.932V
3.329V
5.086V
507.278
45.83°C
230.25V
8
36.703A
8.129A
7.948A
2.366A
520.084
89.114%
2456
45.9
37.80°C
0.960
12.034V
4.921V
3.321V
5.073V
583.619
47.17°C
230.25V
9
41.795A
8.651A
8.447A
2.369A
585.014
88.635%
2452
45.9
38.34°C
0.964
12.023V
4.914V
3.315V
5.066V
660.029
48.63°C
230.26V
10
46.628A
9.175A
8.977A
2.975A
649.854
87.979%
2452
45.9
39.66°C
0.967
12.013V
4.906V
3.308V
5.043V
738.646
50.82°C
230.26V
11
52.066A
9.183A
8.993A
2.980A
714.675
87.296%
2448
45.9
40.30°C
0.969
12.003V
4.902V
3.303V
5.036V
818.676
52.19°C
230.26V
CL1
0.144A
14.004A
13.998A
0.000A
117.481
80.031%
2226
42.9
35.99°C
0.811
12.110V
4.923V
3.343V
5.158V
146.795
43.35°C
230.27V
CL2
54.016A
1.002A
1.000A
1.000A
662.507
88.503%
2455
45.9
39.91°C
0.967
12.017V
4.954V
3.329V
5.103V
748.569
50.78°C
230.28V
The results above are not used in the certification process
20-80瓦负载测试
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.197A
0.498A
0.473A
0.193A
19.588
76.864%
0
<6.0
0.693
12.111V
5.004V
3.381V
5.182V
25.484
115.12V
2
2.447A
1.001A
0.975A
0.387A
39.965
82.862%
0
<6.0
0.868
12.122V
5.000V
3.379V
5.175V
48.231
115.12V
3
3.634A
1.502A
1.450A
0.581A
59.489
76.855%
1018
21.2
0.919
12.132V
4.996V
3.376V
5.167V
77.404
115.12V
4
4.887A
2.004A
1.957A
0.775A
79.867
81.256%
1091
23.9
0.948
12.128V
4.990V
3.372V
5.160V
98.290
115.12V
The results above are not used in the certification process
测试 #
12V
5V
3.3V
5VSB
DC/AC (瓦)
效率
风扇转速 (RPM)
电源供应器噪音 (dB[A])
PF/AC 电压
1
1.194A
0.500A
0.472A
0.193A
19.560
77.761%
0
<6.0
0.329
12.112V
5.006V
3.383V
5.181V
25.154
230.25V
2
2.444A
0.999A
0.977A
0.387A
39.930
83.922%
0
<6.0
0.494
12.123V
5.002V
3.380V
5.174V
47.580
230.25V
3
3.631A
1.502A
1.449A
0.581A
59.444
78.874%
972
20.1
0.627
12.131V
4.995V
3.376V
5.167V
75.366
230.25V
4
4.884A
2.004A
1.954A
0.775A
79.817
83.021%
1077
23.3
0.699
12.127V
4.990V
3.372V
5.160V
96.141
230.25V
The results above are not used in the certification process
纹波测量
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.6 mV
15.7 mV
9.1 mV
18.2 mV
Pass
20% Load
9.0 mV
15.8 mV
9.7 mV
16.8 mV
Pass
30% Load
25.7 mV
15.5 mV
10.0 mV
17.4 mV
Pass
40% Load
24.5 mV
15.9 mV
10.9 mV
17.1 mV
Pass
50% Load
24.1 mV
16.0 mV
11.0 mV
18.1 mV
Pass
60% Load
21.9 mV
16.9 mV
13.4 mV
21.0 mV
Pass
70% Load
24.0 mV
16.7 mV
14.6 mV
21.7 mV
Pass
80% Load
23.2 mV
17.0 mV
16.6 mV
23.5 mV
Pass
90% Load
22.5 mV
18.3 mV
17.9 mV
24.2 mV
Pass
100% Load
33.4 mV
19.5 mV
17.2 mV
28.4 mV
Pass
110% Load
33.9 mV
19.7 mV
18.6 mV
30.6 mV
Pass
Crossload 1
21.7 mV
24.3 mV
18.2 mV
17.5 mV
Pass
Crossload 2
31.8 mV
18.5 mV
11.8 mV
25.7 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.6 mV
16.3 mV
9.8 mV
18.8 mV
Pass
20% Load
7.9 mV
15.8 mV
9.4 mV
19.4 mV
Pass
30% Load
26.4 mV
15.9 mV
10.5 mV
17.3 mV
Pass
40% Load
24.1 mV
15.8 mV
10.7 mV
17.0 mV
Pass
50% Load
23.0 mV
16.5 mV
11.4 mV
17.9 mV
Pass
60% Load
21.8 mV
16.5 mV
13.2 mV
18.2 mV
Pass
70% Load
22.6 mV
16.4 mV
14.1 mV
21.0 mV
Pass
80% Load
22.6 mV
17.4 mV
16.4 mV
21.1 mV
Pass
90% Load
22.1 mV
18.5 mV
16.6 mV
23.4 mV
Pass
100% Load
33.3 mV
19.8 mV
16.8 mV
27.5 mV
Pass
110% Load
33.6 mV
20.7 mV
18.0 mV
26.8 mV
Pass
Crossload 1
24.6 mV
25.3 mV
18.3 mV
17.4 mV
Pass
Crossload 2
33.3 mV
18.3 mV
11.8 mV
22.2 mV
Pass
The results above are not used in the certification process