Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan )
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
85.801%
Average Noise Output (>1450 Load Combinations)
38.02dBA
Average PF (>1450 Load Combinations)
0.975
Efficiency With 10W (≤500W) or 2% (>500W) Load
72.047%
Standby Power Consumption
0.0734W
Non-Accredited
12V Ripple (Full Load)
36.60mV
5V Ripple (Full Load)
21.85mV
3.3V Ripple (Full Load)
18.98mV
5VSB Ripple (Full Load)
41.53mV
12V Load Regulation
1.46%
5V Load Regulation
2.25%
3.3V Load Regulation
2.65%
5VSB Load Regulation
3.04%
Inrush Current
67.882A
Accredited
Average Efficiency (>1450 load combinations)
88.099%
Average Noise Output (>1450 Load Combinations)
37.76dBA
Average PF (>1450 Load Combinations)
0.902
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1835W
Non-Accredited
12V Ripple (Full Load)
37.03mV
5V Ripple (Full Load)
21.68mV
3.3V Ripple (Full Load)
18.88mV
5VSB Ripple (Full Load)
41.27mV
12V Load Regulation
1.27%
5V Load Regulation
2.19%
3.3V Load Regulation
2.60%
5VSB Load Regulation
3.01%
Inrush Current
84.095A
Hold-Up Time & PWR_OK Signal
21.40ms
AC Loss to PWR_OK Hold Up Time
19.60ms
PWR_OK Inactive to DC Loss Delay
1.80ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
21.40
AC Loss to PWR_OK Hold Up Time (ms)
19.60
PWR_OK Inactive to DC Loss Delay (ms)
1.80
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
60.836%
0.025
5.165V
0.383
115.11V
2
0.090A
0.465
69.403%
0.044
5.164V
0.670
115.11V
3
0.550A
2.835
78.121%
0.208
5.153V
3.629
115.11V
4
1.000A
5.142
78.780%
0.312
5.142V
6.527
115.11V
5
1.500A
7.695
78.923%
0.378
5.129V
9.750
115.11V
6
3.001A
15.276
76.799%
0.454
5.091V
19.891
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
47.071%
0.010
5.165V
0.495
230.24V
2
0.090A
0.465
59.236%
0.015
5.164V
0.785
230.24V
3
0.550A
2.835
76.395%
0.070
5.152V
3.711
230.24V
4
1.000A
5.142
78.241%
0.120
5.141V
6.572
230.24V
5
1.500A
7.694
78.856%
0.170
5.129V
9.757
230.24V
6
3.001A
15.276
78.455%
0.277
5.091V
19.471
230.24V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.164A
2.017A
1.971A
0.975A
60.175
79.914%
981
20.3
34.15°C
0.936
12.190V
4.961V
3.348V
5.130V
75.300
39.97°C
115.13V
2
7.304A
3.032A
2.964A
1.173A
119.834
86.597%
967
20.0
34.52°C
0.964
12.176V
4.949V
3.338V
5.117V
138.381
40.81°C
115.12V
3
11.832A
3.543A
3.453A
1.372A
179.708
87.902%
1171
25.7
35.02°C
0.963
12.145V
4.940V
3.331V
5.105V
204.442
41.71°C
115.12V
4
16.365A
4.058A
3.972A
1.572A
239.727
88.104%
1512
32.7
35.82°C
0.974
12.131V
4.930V
3.322V
5.091V
272.095
42.88°C
115.11V
5
20.578A
5.086A
4.980A
1.773A
299.805
87.952%
1630
33.1
36.03°C
0.980
12.115V
4.917V
3.312V
5.077V
340.874
43.72°C
115.11V
6
24.801A
6.119A
5.995A
1.976A
359.902
87.411%
2006
41.2
36.69°C
0.984
12.100V
4.904V
3.302V
5.064V
411.736
44.99°C
115.11V
7
29.005A
7.159A
7.015A
2.179A
419.609
86.611%
2207
42.8
37.03°C
0.987
12.084V
4.891V
3.292V
5.050V
484.475
46.45°C
115.11V
8
33.282A
8.202A
8.041A
2.384A
480.118
85.763%
2427
45.5
37.58°C
0.988
12.070V
4.878V
3.282V
5.035V
559.820
47.60°C
115.11V
9
37.904A
8.730A
8.553A
2.389A
539.440
84.970%
2424
45.4
38.24°C
0.990
12.055V
4.868V
3.274V
5.026V
634.862
48.87°C
115.11V
10
42.373A
9.265A
9.096A
3.001A
599.844
83.809%
2425
45.5
39.41°C
0.991
12.039V
4.858V
3.265V
5.001V
715.725
50.39°C
115.11V
11
47.414A
9.276A
9.116A
3.006A
659.866
82.639%
2424
45.4
40.44°C
0.991
12.025V
4.852V
3.258V
4.992V
798.491
52.30°C
115.10V
CL1
0.144A
14.004A
13.999A
0.000A
116.484
80.418%
2108
41.5
36.32°C
0.961
12.162V
4.886V
3.308V
5.123V
144.849
43.45°C
115.12V
CL2
50.014A
1.002A
1.000A
1.000A
615.697
84.318%
2427
45.5
39.46°C
0.991
12.045V
4.912V
3.291V
5.065V
730.210
50.72°C
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.163A
2.016A
1.970A
0.975A
60.158
80.965%
907
18.1
34.01°C
0.636
12.191V
4.961V
3.348V
5.130V
74.301
39.91°C
230.27V
2
7.303A
3.032A
2.964A
1.173A
119.822
88.031%
1065
22.8
34.73°C
0.800
12.176V
4.949V
3.338V
5.117V
136.113
40.87°C
230.26V
3
11.834A
3.544A
3.452A
1.372A
179.713
89.636%
1203
26.4
35.03°C
0.872
12.144V
4.939V
3.330V
5.104V
200.492
41.59°C
230.27V
4
16.368A
4.058A
3.975A
1.572A
239.733
90.069%
1452
32.4
35.74°C
0.910
12.129V
4.929V
3.321V
5.091V
266.165
42.89°C
230.27V
5
20.580A
5.087A
4.983A
1.773A
299.813
89.993%
1773
38.1
36.03°C
0.930
12.114V
4.916V
3.311V
5.077V
333.152
43.73°C
230.26V
6
24.807A
6.118A
5.998A
1.976A
359.915
89.698%
2036
41.5
36.64°C
0.944
12.098V
4.903V
3.301V
5.063V
401.251
44.84°C
230.26V
7
29.009A
7.160A
7.019A
2.179A
419.627
89.251%
2245
43.0
37.34°C
0.949
12.083V
4.890V
3.291V
5.048V
470.166
46.18°C
230.27V
8
33.292A
8.205A
8.045A
2.385A
480.153
88.677%
2432
45.7
37.56°C
0.956
12.067V
4.877V
3.281V
5.034V
541.462
46.81°C
230.27V
9
37.915A
8.734A
8.556A
2.389A
539.460
88.170%
2426
45.5
38.23°C
0.961
12.052V
4.867V
3.272V
5.025V
611.841
48.22°C
230.27V
10
42.381A
9.266A
9.102A
3.001A
599.869
87.372%
2425
45.5
39.67°C
0.965
12.037V
4.858V
3.264V
5.000V
686.566
50.27°C
230.27V
11
47.429A
9.276A
9.121A
3.006A
659.890
86.686%
2429
45.6
40.28°C
0.966
12.022V
4.851V
3.256V
4.991V
761.242
52.15°C
230.27V
CL1
0.144A
14.005A
13.999A
0.000A
116.488
81.736%
2108
41.5
36.27°C
0.811
12.159V
4.886V
3.308V
5.124V
142.518
43.66°C
230.27V
CL2
50.014A
1.002A
1.001A
1.000A
615.597
87.975%
2424
45.5
39.32°C
0.964
12.043V
4.911V
3.290V
5.065V
699.741
50.61°C
230.27V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.196A
0.503A
0.477A
0.194A
19.684
77.536%
0
<6.0
0.699
12.190V
4.975V
3.357V
5.158V
25.387
115.15V
2
2.441A
1.006A
0.986A
0.389A
40.132
83.327%
0
<6.0
0.873
12.217V
4.970V
3.354V
5.150V
48.162
115.15V
3
3.624A
1.511A
1.463A
0.584A
59.586
80.644%
687
11.0
0.932
12.191V
4.965V
3.350V
5.141V
73.888
115.15V
4
4.869A
2.018A
1.972A
0.779A
79.934
83.494%
886
17.4
0.942
12.185V
4.959V
3.346V
5.133V
95.736
115.14V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.193A
0.504A
0.478A
0.194A
19.659
78.068%
0
<6.0
0.337
12.192V
4.977V
3.358V
5.157V
25.182
230.30V
2
2.436A
1.007A
0.984A
0.389A
40.077
84.210%
0
<6.0
0.503
12.219V
4.972V
3.355V
5.149V
47.592
230.30V
3
3.619A
1.511A
1.464A
0.584A
59.534
81.616%
779
13.9
0.633
12.192V
4.966V
3.350V
5.141V
72.944
230.28V
4
4.867A
2.017A
1.970A
0.779A
79.900
84.893%
872
16.9
0.710
12.185V
4.960V
3.346V
5.133V
94.119
230.27V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.6 mV
17.9 mV
11.5 mV
17.7 mV
Pass
20% Load
25.1 mV
17.8 mV
11.8 mV
24.1 mV
Pass
30% Load
24.4 mV
18.2 mV
12.3 mV
29.7 mV
Pass
40% Load
23.6 mV
18.1 mV
12.0 mV
31.6 mV
Pass
50% Load
22.0 mV
18.0 mV
12.6 mV
32.8 mV
Pass
60% Load
22.5 mV
17.5 mV
13.9 mV
32.4 mV
Pass
70% Load
23.8 mV
18.8 mV
15.0 mV
33.6 mV
Pass
80% Load
25.0 mV
19.1 mV
17.3 mV
36.1 mV
Pass
90% Load
24.3 mV
19.8 mV
17.1 mV
35.5 mV
Pass
100% Load
36.6 mV
21.9 mV
19.0 mV
41.5 mV
Pass
110% Load
38.6 mV
22.0 mV
18.7 mV
42.8 mV
Pass
Crossload 1
37.1 mV
25.5 mV
19.5 mV
26.7 mV
Pass
Crossload 2
35.9 mV
20.6 mV
14.7 mV
37.1 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.9 mV
18.4 mV
11.2 mV
19.9 mV
Pass
20% Load
25.3 mV
18.0 mV
11.5 mV
20.3 mV
Pass
30% Load
24.8 mV
17.5 mV
12.0 mV
24.2 mV
Pass
40% Load
24.1 mV
17.5 mV
12.4 mV
27.9 mV
Pass
50% Load
23.1 mV
17.9 mV
12.5 mV
29.4 mV
Pass
60% Load
22.7 mV
17.4 mV
14.1 mV
31.2 mV
Pass
70% Load
22.8 mV
19.7 mV
15.6 mV
35.6 mV
Pass
80% Load
24.4 mV
19.6 mV
16.8 mV
34.5 mV
Pass
90% Load
24.1 mV
20.1 mV
17.1 mV
36.0 mV
Pass
100% Load
37.0 mV
21.7 mV
18.9 mV
41.3 mV
Pass
110% Load
39.2 mV
21.5 mV
19.6 mV
41.7 mV
Pass
Crossload 1
41.8 mV
25.4 mV
18.6 mV
23.0 mV
Pass
Crossload 2
38.7 mV
22.4 mV
14.0 mV
38.5 mV
Pass
The results above are not used in the certification process