Thermal Control DF1202512SELN (120mm, 12V, 0.25A, Rifle Bearing Fan)
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
85.601%
Average Noise Output (>1450 Load Combinations)
30.07dBA
Average PF (>1450 Load Combinations)
0.974
Efficiency With 10W (≤500W) or 2% (>500W) Load
68.580%
Standby Power Consumption
0.0756W
Non-Accredited
12V Ripple (Full Load)
48.99mV
5V Ripple (Full Load)
24.23mV
3.3V Ripple (Full Load)
19.35mV
5VSB Ripple (Full Load)
39.17mV
12V Load Regulation
1.07%
5V Load Regulation
1.96%
3.3V Load Regulation
2.26%
5VSB Load Regulation
2.79%
Inrush Current
62.537A
Accredited
Average Efficiency (>1450 load combinations)
87.864%
Average Noise Output (>1450 Load Combinations)
29.96dBA
Average PF (>1450 Load Combinations)
0.896
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1812W
Non-Accredited
12V Ripple (Full Load)
50.85mV
5V Ripple (Full Load)
23.53mV
3.3V Ripple (Full Load)
18.94mV
5VSB Ripple (Full Load)
37.88mV
12V Load Regulation
1.09%
5V Load Regulation
1.94%
3.3V Load Regulation
2.26%
5VSB Load Regulation
2.79%
Inrush Current
71.267A
Hold-Up Time & PWR_OK Signal
17.20ms
AC Loss to PWR_OK Hold Up Time
15.80ms
PWR_OK Inactive to DC Loss Delay
1.40ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
17.2
AC Loss to PWR_OK Hold Up Time (ms)
15.8
PWR_OK Inactive to DC Loss Delay (ms)
1.4
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.234
60.622%
0.025
5.178V
0.386
115.13V
2
0.090A
0.467
69.806%
0.044
5.177V
0.669
115.13V
3
0.550A
2.842
78.835%
0.207
5.166V
3.605
115.13V
4
1.000A
5.156
79.543%
0.310
5.155V
6.482
115.12V
5
1.500A
7.715
79.643%
0.376
5.142V
9.687
115.13V
6
3.000A
15.314
77.579%
0.455
5.105V
19.740
115.14V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.234
47.177%
0.010
5.178V
0.496
230.29V
2
0.090A
0.467
59.566%
0.015
5.177V
0.784
230.28V
3
0.550A
2.842
77.186%
0.070
5.166V
3.682
230.29V
4
1.000A
5.156
79.068%
0.120
5.155V
6.521
230.29V
5
1.500A
7.715
79.799%
0.169
5.142V
9.668
230.29V
6
3.000A
15.314
79.401%
0.277
5.105V
19.287
230.29V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.319A
1.999A
1.966A
0.972A
49.779
82.806%
0
<6.0
40.22°C
0.913
12.149V
5.006V
3.356V
5.144V
60.115
34.60°C
115.13V
2
5.688A
3.005A
2.956A
1.169A
99.854
85.826%
0
<6.0
41.17°C
0.964
12.122V
4.995V
3.348V
5.131V
116.345
34.88°C
115.13V
3
9.393A
3.513A
3.444A
1.367A
149.764
87.212%
1044
24.2
35.47°C
0.968
12.110V
4.985V
3.340V
5.120V
171.725
42.51°C
115.13V
4
13.107A
4.020A
3.962A
1.566A
199.744
87.746%
1121
26.2
35.80°C
0.972
12.096V
4.975V
3.332V
5.109V
227.638
43.70°C
115.13V
5
16.500A
5.040A
4.965A
1.766A
249.881
87.604%
1251
29.1
36.05°C
0.977
12.083V
4.963V
3.323V
5.096V
285.238
44.55°C
115.13V
6
19.897A
6.058A
5.973A
1.968A
299.962
87.162%
1460
33.0
36.77°C
0.981
12.070V
4.952V
3.315V
5.084V
344.142
45.60°C
115.13V
7
23.302A
7.085A
6.985A
2.170A
350.078
86.543%
1487
33.1
37.36°C
0.984
12.058V
4.941V
3.306V
5.071V
404.515
46.52°C
115.12V
8
26.711A
8.116A
8.005A
2.374A
400.177
85.786%
1486
33.1
37.73°C
0.986
12.046V
4.930V
3.298V
5.057V
466.485
47.40°C
115.13V
9
30.524A
8.636A
8.508A
2.377A
449.881
84.931%
1488
33.1
38.53°C
0.988
12.035V
4.923V
3.292V
5.049V
529.701
48.80°C
115.12V
10
34.115A
9.160A
9.044A
2.986A
499.885
83.626%
1489
33.1
39.31°C
0.989
12.023V
4.914V
3.284V
5.026V
597.760
50.30°C
115.12V
11
38.310A
9.170A
9.057A
2.990A
549.897
81.932%
1489
33.1
40.30°C
0.989
12.012V
4.909V
3.279V
5.018V
671.163
51.75°C
115.12V
CL1
0.143A
14.005A
13.999A
0.000A
117.225
80.682%
1484
33.1
36.04°C
0.973
12.110V
4.931V
3.317V
5.136V
145.292
44.24°C
115.13V
CL2
41.594A
1.004A
1.000A
1.000A
513.715
84.298%
1490
33.1
39.89°C
0.989
12.029V
4.963V
3.309V
5.089V
609.402
50.91°C
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.320A
1.998A
1.966A
0.972A
49.785
84.197%
0
<6.0
39.94°C
0.600
12.150V
5.005V
3.356V
5.144V
59.129
34.11°C
230.29V
2
5.690A
3.004A
2.956A
1.170A
99.865
87.397%
0
<6.0
40.97°C
0.782
12.120V
4.994V
3.348V
5.131V
114.266
34.55°C
230.29V
3
9.397A
3.513A
3.442A
1.368A
149.775
88.999%
1021
24.1
35.06°C
0.852
12.107V
4.984V
3.339V
5.120V
168.288
42.00°C
230.29V
4
13.109A
4.023A
3.964A
1.566A
199.742
89.634%
1090
24.8
35.51°C
0.897
12.093V
4.974V
3.331V
5.109V
222.841
42.81°C
230.29V
5
16.505A
5.040A
4.967A
1.766A
249.872
89.662%
1246
28.5
36.25°C
0.921
12.079V
4.962V
3.322V
5.096V
278.681
43.89°C
230.29V
6
19.901A
6.062A
5.974A
1.968A
299.953
89.442%
1427
32.4
36.84°C
0.935
12.067V
4.951V
3.313V
5.083V
335.360
44.86°C
230.29V
7
23.308A
7.090A
6.990A
2.171A
350.074
89.040%
1489
33.1
37.03°C
0.945
12.054V
4.939V
3.304V
5.070V
393.163
45.60°C
230.28V
8
26.720A
8.119A
8.010A
2.374A
400.178
88.539%
1489
33.1
37.87°C
0.953
12.042V
4.928V
3.296V
5.056V
451.979
47.16°C
230.29V
9
30.538A
8.640A
8.514A
2.378A
449.887
88.031%
1494
33.2
38.12°C
0.957
12.030V
4.920V
3.289V
5.048V
511.055
48.20°C
230.29V
10
34.131A
9.166A
9.053A
2.987A
499.886
87.331%
1495
33.2
39.90°C
0.959
12.017V
4.912V
3.281V
5.024V
572.405
50.63°C
230.29V
11
38.326A
9.175A
9.064A
2.992A
549.904
86.459%
1490
33.1
40.46°C
0.964
12.007V
4.907V
3.276V
5.016V
636.027
51.91°C
230.29V
CL1
0.145A
14.004A
14.000A
0.000A
117.191
82.358%
1482
33.1
36.15°C
0.827
12.107V
4.929V
3.315V
5.135V
142.295
43.88°C
230.30V
CL2
41.595A
1.003A
1.001A
1.000A
513.516
87.965%
1494
33.2
39.31°C
0.960
12.024V
4.962V
3.308V
5.089V
583.772
50.37°C
230.29V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.500A
0.475A
0.194A
19.672
76.637%
0
<6.0
0.737
12.135V
5.017V
3.364V
5.170V
25.669
115.13V
2
2.451A
0.998A
0.982A
0.388A
40.067
82.408%
0
<6.0
0.877
12.143V
5.012V
3.360V
5.162V
48.620
115.13V
3
3.633A
1.497A
1.460A
0.582A
59.548
84.344%
0
<6.0
0.927
12.153V
5.007V
3.357V
5.154V
70.601
115.13V
4
4.893A
2.000A
1.969A
0.777A
79.953
85.365%
0
<6.0
0.950
12.129V
5.003V
3.353V
5.146V
93.660
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.201A
0.500A
0.476A
0.194A
19.688
77.787%
0
<6.0
0.356
12.135V
5.017V
3.364V
5.170V
25.310
230.30V
2
2.453A
0.997A
0.982A
0.388A
40.081
83.519%
0
<6.0
0.536
12.141V
5.012V
3.360V
5.162V
47.990
230.29V
3
3.634A
1.497A
1.460A
0.582A
59.552
85.929%
0
<6.0
0.647
12.151V
5.007V
3.356V
5.154V
69.304
230.29V
4
4.895A
2.001A
1.968A
0.778A
79.965
86.801%
0
<6.0
0.724
12.126V
5.002V
3.352V
5.145V
92.125
230.29V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
88.0 mV
20.8 mV
12.2 mV
19.3 mV
Pass
20% Load
88.9 mV
21.0 mV
13.3 mV
18.4 mV
Pass
30% Load
35.1 mV
19.6 mV
12.5 mV
20.6 mV
Pass
40% Load
32.5 mV
18.9 mV
12.6 mV
24.8 mV
Pass
50% Load
29.9 mV
18.3 mV
13.3 mV
27.4 mV
Pass
60% Load
29.7 mV
19.4 mV
15.6 mV
30.7 mV
Pass
70% Load
26.5 mV
18.5 mV
13.2 mV
27.1 mV
Pass
80% Load
34.2 mV
21.2 mV
18.4 mV
33.7 mV
Pass
90% Load
33.5 mV
21.3 mV
17.5 mV
33.9 mV
Pass
100% Load
49.0 mV
24.2 mV
19.4 mV
39.2 mV
Pass
110% Load
49.5 mV
24.8 mV
18.6 mV
39.3 mV
Pass
Crossload 1
43.2 mV
26.5 mV
20.6 mV
20.5 mV
Pass
Crossload 2
46.6 mV
22.5 mV
14.4 mV
35.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
89.1 mV
20.3 mV
11.9 mV
18.8 mV
Pass
20% Load
87.5 mV
20.4 mV
12.4 mV
18.0 mV
Pass
30% Load
34.7 mV
18.1 mV
11.9 mV
17.8 mV
Pass
40% Load
34.6 mV
18.7 mV
12.6 mV
22.0 mV
Pass
50% Load
32.6 mV
20.2 mV
12.7 mV
24.2 mV
Pass
60% Load
33.0 mV
18.9 mV
14.6 mV
26.4 mV
Pass
70% Load
33.6 mV
20.0 mV
15.5 mV
30.6 mV
Pass
80% Load
37.2 mV
20.2 mV
17.2 mV
33.0 mV
Pass
90% Load
33.6 mV
21.3 mV
17.2 mV
34.6 mV
Pass
100% Load
50.9 mV
23.5 mV
18.9 mV
37.9 mV
Pass
110% Load
50.6 mV
22.5 mV
17.9 mV
36.9 mV
Pass
Crossload 1
44.4 mV
27.2 mV
19.3 mV
18.5 mV
Pass
Crossload 2
50.9 mV
21.7 mV
15.5 mV
35.6 mV
Pass
The results above are not used in the certification process