Thermal Control DF1202512SELN (120mm, 12V, 0.25A, Rifle Bearing Fan)
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
84.602%
Average Noise Output (>1450 Load Combinations)
27.85dBA
Average PF (>1450 Load Combinations)
0.974
Efficiency With 10W (≤500W) or 2% (>500W) Load
71.924%
Standby Power Consumption
0.0743W
Non-Accredited
12V Ripple (Full Load)
45.42mV
5V Ripple (Full Load)
23.01mV
3.3V Ripple (Full Load)
30.24mV
5VSB Ripple (Full Load)
26.42mV
12V Load Regulation
1.29%
5V Load Regulation
2.91%
3.3V Load Regulation
2.94%
5VSB Load Regulation
3.91%
Inrush Current
60.395A
Accredited
Average Efficiency (>1450 load combinations)
87.142%
Average Noise Output (>1450 Load Combinations)
27.32dBA
Average PF (>1450 Load Combinations)
0.892
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1865W
Non-Accredited
12V Ripple (Full Load)
44.34mV
5V Ripple (Full Load)
23.05mV
3.3V Ripple (Full Load)
30.02mV
5VSB Ripple (Full Load)
25.61mV
12V Load Regulation
1.32%
5V Load Regulation
2.85%
3.3V Load Regulation
2.85%
5VSB Load Regulation
3.80%
Inrush Current
59.320A
Hold-Up Time & PWR_OK Signal
17.50ms
AC Loss to PWR_OK Hold Up Time
15.80ms
PWR_OK Inactive to DC Loss Delay
1.70ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
17.5
AC Loss to PWR_OK Hold Up Time (ms)
15.8
PWR_OK Inactive to DC Loss Delay (ms)
1.7
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
60.836%
0.025
5.172V
0.383
115.13V
2
0.090A
0.466
70.075%
0.043
5.171V
0.665
115.12V
3
0.550A
2.836
79.107%
0.197
5.155V
3.585
115.13V
4
1.000A
5.142
79.795%
0.288
5.140V
6.444
115.12V
5
1.500A
7.686
79.879%
0.347
5.123V
9.622
115.12V
6
3.000A
15.217
77.582%
0.427
5.072V
19.614
115.12V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
46.787%
0.010
5.173V
0.498
230.30V
2
0.090A
0.466
59.439%
0.015
5.171V
0.784
230.30V
3
0.550A
2.837
77.197%
0.069
5.156V
3.675
230.30V
4
1.000A
5.142
79.047%
0.118
5.141V
6.505
230.30V
5
1.500A
7.687
79.699%
0.164
5.124V
9.645
230.30V
6
3.000A
15.218
79.141%
0.264
5.072V
19.229
230.30V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.927A
2.014A
1.983A
0.976A
44.892
83.235%
0
<6.0
40.71°C
0.900
12.084V
4.968V
3.327V
5.127V
53.934
35.00°C
115.13V
2
4.839A
3.031A
2.985A
1.175A
89.409
84.754%
870
18.5
35.99°C
0.958
12.089V
4.951V
3.316V
5.110V
105.492
42.21°C
115.12V
3
8.167A
3.545A
3.477A
1.375A
134.501
86.311%
904
21.2
36.46°C
0.974
12.060V
4.939V
3.306V
5.094V
155.833
43.38°C
115.12V
4
11.504A
4.062A
4.002A
1.576A
179.727
86.760%
987
23.1
36.65°C
0.972
12.041V
4.926V
3.297V
5.078V
207.154
44.16°C
115.12V
5
14.517A
5.093A
5.021A
1.779A
225.026
86.532%
1141
27.4
37.35°C
0.977
12.022V
4.909V
3.286V
5.060V
260.050
45.33°C
115.12V
6
17.472A
6.134A
6.046A
1.984A
269.545
86.070%
1292
29.0
37.93°C
0.981
12.004V
4.892V
3.275V
5.042V
313.170
46.84°C
115.12V
7
20.503A
7.181A
7.078A
2.190A
314.851
85.381%
1473
33.0
38.40°C
0.984
11.986V
4.875V
3.263V
5.023V
368.761
48.00°C
115.12V
8
23.543A
8.236A
8.117A
2.398A
360.171
84.492%
1480
33.1
38.64°C
0.986
11.968V
4.858V
3.252V
5.005V
426.279
48.69°C
115.13V
9
26.992A
8.774A
8.633A
2.404A
405.067
83.590%
1481
33.1
39.34°C
0.988
11.950V
4.845V
3.243V
4.994V
484.585
49.74°C
115.13V
10
30.182A
9.315A
9.187A
3.024A
449.876
82.170%
1481
33.1
39.93°C
0.989
11.933V
4.832V
3.233V
4.961V
547.497
50.93°C
115.13V
11
33.991A
9.332A
9.209A
3.030A
494.681
80.377%
1480
33.1
40.05°C
0.990
11.914V
4.823V
3.225V
4.952V
615.448
51.56°C
115.15V
CL1
0.142A
14.002A
14.000A
0.000A
115.472
79.624%
1408
32.1
37.64°C
0.972
12.060V
4.853V
3.272V
5.110V
145.022
45.98°C
115.13V
CL2
37.512A
1.003A
0.998A
1.000A
461.016
83.187%
1482
33.1
39.69°C
0.990
11.937V
4.906V
3.266V
5.056V
554.190
50.66°C
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.928A
2.013A
1.984A
0.976A
44.906
84.717%
0
<6.0
41.00°C
0.576
12.086V
4.968V
3.327V
5.126V
53.007
34.86°C
230.32V
2
4.839A
3.030A
2.986A
1.175A
89.404
86.442%
832
17.7
35.64°C
0.762
12.089V
4.951V
3.316V
5.109V
103.427
42.15°C
230.32V
3
8.167A
3.543A
3.478A
1.375A
134.492
88.326%
874
18.9
36.01°C
0.845
12.060V
4.938V
3.306V
5.094V
152.268
43.25°C
230.31V
4
11.503A
4.062A
4.002A
1.576A
179.714
88.917%
1034
24.2
36.75°C
0.888
12.041V
4.926V
3.297V
5.078V
202.114
44.37°C
230.31V
5
14.515A
5.093A
5.021A
1.779A
225.002
88.948%
1137
26.9
37.50°C
0.913
12.022V
4.909V
3.286V
5.060V
252.958
45.83°C
230.31V
6
17.472A
6.134A
6.044A
1.984A
269.521
88.705%
1272
29.1
37.84°C
0.929
12.003V
4.892V
3.275V
5.042V
303.840
46.49°C
230.32V
7
20.503A
7.181A
7.077A
2.190A
314.831
88.314%
1428
32.5
38.09°C
0.940
11.985V
4.875V
3.263V
5.024V
356.492
47.10°C
230.32V
8
23.544A
8.236A
8.119A
2.398A
360.144
87.761%
1480
33.1
38.92°C
0.948
11.966V
4.858V
3.252V
5.005V
410.370
48.85°C
230.33V
9
26.996A
8.773A
8.633A
2.403A
405.051
87.263%
1475
33.1
39.37°C
0.955
11.948V
4.845V
3.243V
4.994V
464.174
49.78°C
230.32V
10
30.188A
9.315A
9.186A
3.024A
449.856
86.568%
1476
33.1
39.71°C
0.959
11.930V
4.832V
3.233V
4.962V
519.655
50.48°C
230.32V
11
33.995A
9.332A
9.209A
3.030A
494.664
85.936%
1476
33.1
40.39°C
0.962
11.912V
4.823V
3.225V
4.953V
575.620
52.10°C
230.32V
CL1
0.144A
14.002A
13.999A
0.000A
115.478
81.503%
1449
32.9
37.81°C
0.832
12.057V
4.852V
3.272V
5.109V
141.686
45.70°C
230.31V
CL2
37.514A
1.002A
0.999A
1.000A
460.927
87.572%
1475
33.1
39.95°C
0.959
11.934V
4.906V
3.266V
5.056V
526.339
50.48°C
230.32V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.201A
0.501A
0.479A
0.194A
19.588
79.108%
0
<6.0
0.750
12.066V
4.985V
3.336V
5.163V
24.761
115.13V
2
2.460A
1.005A
0.988A
0.388A
40.005
83.276%
0
<6.0
0.884
12.079V
4.977V
3.331V
5.151V
48.039
115.13V
3
3.652A
1.510A
1.472A
0.584A
59.489
84.881%
0
<6.0
0.929
12.072V
4.970V
3.326V
5.140V
70.085
115.13V
4
4.917A
2.016A
1.984A
0.780A
79.881
85.811%
0
<6.0
0.956
12.058V
4.962V
3.321V
5.128V
93.090
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.203A
0.502A
0.479A
0.194A
19.627
80.544%
0
<6.0
0.353
12.074V
4.986V
3.337V
5.162V
24.368
230.32V
2
2.462A
1.005A
0.990A
0.389A
40.055
85.100%
0
<6.0
0.540
12.084V
4.978V
3.331V
5.150V
47.068
230.32V
3
3.654A
1.511A
1.472A
0.584A
59.526
86.674%
0
<6.0
0.654
12.074V
4.970V
3.326V
5.139V
68.678
230.32V
4
4.919A
2.015A
1.986A
0.780A
79.906
87.620%
0
<6.0
0.732
12.058V
4.962V
3.321V
5.127V
91.196
230.32V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
81.2 mV
18.2 mV
15.2 mV
18.6 mV
Pass
20% Load
38.5 mV
16.0 mV
17.4 mV
18.9 mV
Pass
30% Load
34.1 mV
16.7 mV
19.2 mV
20.2 mV
Pass
40% Load
32.4 mV
17.1 mV
18.3 mV
20.0 mV
Pass
50% Load
30.7 mV
16.7 mV
19.9 mV
19.6 mV
Pass
60% Load
32.0 mV
17.7 mV
20.6 mV
19.9 mV
Pass
70% Load
39.3 mV
18.0 mV
23.6 mV
20.0 mV
Pass
80% Load
32.6 mV
20.6 mV
26.8 mV
21.1 mV
Pass
90% Load
33.2 mV
20.9 mV
28.2 mV
23.2 mV
Pass
100% Load
45.4 mV
23.0 mV
30.2 mV
26.4 mV
Pass
110% Load
45.3 mV
22.4 mV
29.3 mV
25.6 mV
Pass
Crossload 1
41.9 mV
26.9 mV
34.9 mV
20.1 mV
Pass
Crossload 2
44.5 mV
17.6 mV
15.6 mV
23.2 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
75.1 mV
16.9 mV
15.4 mV
18.9 mV
Pass
20% Load
41.2 mV
15.7 mV
16.8 mV
19.2 mV
Pass
30% Load
35.9 mV
17.2 mV
17.0 mV
18.5 mV
Pass
40% Load
33.9 mV
17.1 mV
18.3 mV
19.4 mV
Pass
50% Load
32.0 mV
16.9 mV
18.0 mV
18.7 mV
Pass
60% Load
32.1 mV
17.6 mV
20.4 mV
19.3 mV
Pass
70% Load
37.6 mV
18.8 mV
23.1 mV
21.5 mV
Pass
80% Load
31.7 mV
20.1 mV
27.5 mV
21.2 mV
Pass
90% Load
31.3 mV
20.5 mV
28.0 mV
20.8 mV
Pass
100% Load
44.3 mV
23.1 mV
30.0 mV
25.6 mV
Pass
110% Load
45.5 mV
22.1 mV
29.8 mV
24.2 mV
Pass
Crossload 1
41.3 mV
26.5 mV
35.1 mV
19.5 mV
Pass
Crossload 2
44.7 mV
17.4 mV
15.8 mV
22.4 mV
Pass
The results above are not used in the certification process