ErP Lot 6 2010: ✓
ErP Lot 6 2013: ✓
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.686%
Average Noise Output (>1450 Load Combinations)
22.32dBA
Average PF (>1450 Load Combinations)
0.986
Efficiency With 10W (≤500W) or 2% (>500W) Load
56.837%
Standby Power Consumption
0.0999W
Non-Accredited
12V Ripple (Full Load)
46.31mV
5V Ripple (Full Load)
19.71mV
3.3V Ripple (Full Load)
18.10mV
5VSB Ripple (Full Load)
16.75mV
12V Load Regulation
1.22%
5V Load Regulation
2.73%
3.3V Load Regulation
3.87%
5VSB Load Regulation
3.63%
Inrush Current
39.019A
Accredited
Average Efficiency (>1450 load combinations)
90.512%
Average Noise Output (>1450 Load Combinations)
23.19dBA
Average PF (>1450 Load Combinations)
0.933
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1422W
Non-Accredited
12V Ripple (Full Load)
47.09mV
5V Ripple (Full Load)
18.81mV
3.3V Ripple (Full Load)
16.01mV
5VSB Ripple (Full Load)
15.67mV
12V Load Regulation
1.17%
5V Load Regulation
2.69%
3.3V Load Regulation
3.78%
5VSB Load Regulation
3.59%
Inrush Current
88.193A
Hold-Up Time & PWR_OK Signal
19.80ms
AC Loss to PWR_OK Hold Up Time
15.40ms
PWR_OK Inactive to DC Loss Delay
4.40ms
OPP (0.00°C / 0.00°C)
133.22%
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
19.8
AC Loss to PWR_OK Hold Up Time (ms)
15.4
PWR_OK Inactive to DC Loss Delay (ms)
4.4
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
71.429%
0.045
5.101V
0.322
115.13V
2
0.090A
0.460
75.908%
0.082
5.099V
0.606
115.13V
3
0.550A
2.798
79.806%
0.312
5.086V
3.506
115.13V
4
1.000A
5.074
79.195%
0.393
5.073V
6.407
115.13V
5
1.500A
7.590
78.539%
0.436
5.059V
9.664
115.13V
6
3.001A
15.051
77.803%
0.493
5.016V
19.345
115.13V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
56.235%
0.017
5.101V
0.409
230.27V
2
0.090A
0.460
64.067%
0.030
5.099V
0.718
230.27V
3
0.550A
2.798
74.534%
0.141
5.086V
3.754
230.28V
4
1.000A
5.075
74.753%
0.222
5.074V
6.789
230.28V
5
1.500A
7.590
78.336%
0.276
5.059V
9.689
230.28V
6
3.001A
15.054
79.152%
0.364
5.017V
19.019
230.27V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.171A
1.982A
1.951A
0.988A
60.152
83.084%
767
14.5
40.08°C
0.957
12.156V
5.048V
3.382V
5.063V
72.399
43.62°C
115.13V
2
7.326A
2.982A
2.940A
1.189A
119.852
88.137%
770
14.7
40.75°C
0.986
12.140V
5.033V
3.369V
5.047V
135.984
44.72°C
115.12V
3
11.853A
3.487A
3.425A
1.391A
179.747
89.740%
774
14.8
41.12°C
0.982
12.127V
5.021V
3.357V
5.032V
200.297
45.57°C
115.12V
4
16.393A
3.996A
3.945A
1.595A
239.757
90.265%
778
14.9
41.76°C
0.985
12.112V
5.008V
3.344V
5.016V
265.615
46.46°C
115.12V
5
20.613A
5.010A
4.955A
1.800A
299.851
90.232%
783
15.0
42.43°C
0.989
12.096V
4.993V
3.330V
5.000V
332.312
47.55°C
115.12V
6
24.845A
6.030A
5.972A
2.008A
359.949
89.862%
993
22.7
42.63°C
0.991
12.080V
4.977V
3.316V
4.983V
400.556
48.54°C
115.12V
7
29.060A
7.057A
7.000A
2.216A
419.663
89.288%
1447
33.1
43.09°C
0.993
12.063V
4.961V
3.300V
4.965V
470.012
49.25°C
115.12V
8
33.356A
8.091A
8.034A
2.426A
480.178
88.618%
1831
39.6
43.75°C
0.994
12.045V
4.945V
3.285V
4.948V
541.851
50.31°C
115.12V
9
37.986A
8.620A
8.556A
2.431A
539.485
88.077%
1848
39.9
44.25°C
0.995
12.030V
4.932V
3.272V
4.938V
612.516
51.47°C
115.12V
10
42.465A
9.155A
9.118A
3.057A
599.903
87.358%
1857
40.1
45.53°C
0.995
12.014V
4.917V
3.258V
4.909V
686.717
53.63°C
115.12V
11
47.522A
9.177A
9.149A
3.063A
659.932
86.709%
1864
40.2
46.61°C
0.996
11.999V
4.905V
3.246V
4.899V
761.089
55.54°C
115.12V
CL1
0.147A
12.001A
11.999A
0.000A
101.948
83.153%
832
16.1
42.78°C
0.986
12.127V
5.000V
3.347V
5.062V
122.603
47.65°C
115.13V
CL2
48.010A
1.002A
1.001A
1.000A
591.238
88.456%
1857
40.1
45.39°C
0.995
12.039V
4.957V
3.287V
4.989V
668.399
53.88°C
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.171A
1.981A
1.953A
0.988A
60.151
84.284%
765
14.3
40.45°C
0.764
12.155V
5.048V
3.382V
5.063V
71.367
44.17°C
230.27V
2
7.327A
2.982A
2.937A
1.189A
119.850
89.456%
768
14.5
40.80°C
0.876
12.140V
5.033V
3.368V
5.046V
133.976
45.20°C
230.27V
3
11.856A
3.485A
3.427A
1.391A
179.748
91.115%
771
14.7
41.42°C
0.919
12.125V
5.020V
3.356V
5.031V
197.275
46.20°C
230.27V
4
16.397A
3.995A
3.946A
1.595A
239.767
91.777%
774
14.8
41.68°C
0.941
12.110V
5.007V
3.344V
5.016V
261.250
47.15°C
230.26V
5
20.614A
5.012A
4.956A
1.801A
299.848
91.898%
781
14.9
42.25°C
0.955
12.095V
4.992V
3.329V
4.999V
326.283
48.37°C
230.27V
6
24.849A
6.031A
5.973A
2.008A
359.948
91.745%
903
19.4
42.52°C
0.964
12.078V
4.977V
3.315V
4.982V
392.334
49.24°C
230.27V
7
29.065A
7.057A
6.999A
2.216A
419.661
91.372%
1371
31.1
43.09°C
0.970
12.061V
4.961V
3.300V
4.965V
459.290
50.20°C
230.27V
8
33.360A
8.094A
8.036A
2.426A
480.171
90.887%
1830
39.6
43.57°C
0.973
12.043V
4.944V
3.285V
4.947V
528.316
51.47°C
230.27V
9
37.990A
8.623A
8.559A
2.432A
539.476
90.586%
1847
39.9
44.97°C
0.977
12.028V
4.931V
3.272V
4.937V
595.540
53.05°C
230.27V
10
42.468A
9.157A
9.119A
3.058A
599.894
90.117%
1858
40.1
45.93°C
0.979
12.013V
4.916V
3.257V
4.908V
665.686
54.40°C
230.27V
11
47.524A
9.178A
9.153A
3.064A
659.920
89.753%
1865
40.2
46.63°C
0.980
11.998V
4.905V
3.245V
4.898V
735.262
55.49°C
230.27V
CL1
0.147A
12.003A
11.998A
0.000A
101.942
84.333%
831
16.1
42.52°C
0.862
12.126V
4.999V
3.347V
5.062V
120.881
48.58°C
230.27V
CL2
48.016A
1.002A
1.002A
1.000A
591.216
91.210%
1858
40.1
46.12°C
0.979
12.037V
4.956V
3.287V
4.988V
648.191
54.08°C
230.27V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.199A
0.494A
0.471A
0.196A
19.678
66.807%
774
14.8
0.856
12.159V
5.063V
3.395V
5.094V
29.455
115.13V
2
2.448A
0.991A
0.974A
0.394A
40.085
79.449%
765
14.3
0.930
12.162V
5.055V
3.389V
5.085V
50.454
115.13V
3
3.630A
1.487A
1.449A
0.591A
59.538
83.290%
764
14.2
0.956
12.156V
5.050V
3.384V
5.075V
71.483
115.13V
4
4.883A
1.984A
1.952A
0.790A
79.933
85.504%
765
14.3
0.970
12.150V
5.044V
3.379V
5.066V
93.484
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.192A
0.494A
0.471A
0.196A
19.600
69.012%
754
14.0
0.551
12.166V
5.063V
3.395V
5.094V
28.401
230.27V
2
2.447A
0.988A
0.974A
0.394A
40.053
80.217%
754
14.0
0.686
12.160V
5.055V
3.388V
5.084V
49.931
230.27V
3
3.630A
1.485A
1.449A
0.591A
59.524
84.416%
757
14.0
0.761
12.155V
5.050V
3.384V
5.075V
70.513
230.27V
4
4.883A
1.984A
1.954A
0.790A
79.934
86.867%
761
14.2
0.814
12.149V
5.044V
3.378V
5.066V
92.019
230.27V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.8 mV
9.6 mV
10.8 mV
12.0 mV
Pass
20% Load
25.4 mV
10.7 mV
11.2 mV
12.4 mV
Pass
30% Load
33.3 mV
11.2 mV
12.0 mV
11.8 mV
Pass
40% Load
36.8 mV
11.7 mV
11.0 mV
12.2 mV
Pass
50% Load
35.9 mV
13.1 mV
11.9 mV
12.8 mV
Pass
60% Load
30.0 mV
15.9 mV
12.4 mV
12.8 mV
Pass
70% Load
27.7 mV
15.2 mV
13.3 mV
13.4 mV
Pass
80% Load
27.1 mV
17.3 mV
15.2 mV
15.5 mV
Pass
90% Load
30.5 mV
18.0 mV
15.4 mV
15.6 mV
Pass
100% Load
46.3 mV
19.7 mV
18.1 mV
16.8 mV
Pass
110% Load
50.6 mV
20.9 mV
16.7 mV
18.9 mV
Pass
Crossload 1
29.8 mV
15.1 mV
16.3 mV
16.3 mV
Pass
Crossload 2
45.5 mV
16.3 mV
13.9 mV
16.6 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
22.2 mV
9.7 mV
11.2 mV
12.1 mV
Pass
20% Load
30.7 mV
10.4 mV
10.8 mV
12.2 mV
Pass
30% Load
39.8 mV
11.1 mV
11.2 mV
12.3 mV
Pass
40% Load
46.3 mV
11.6 mV
11.0 mV
12.9 mV
Pass
50% Load
41.5 mV
12.6 mV
11.5 mV
13.6 mV
Pass
60% Load
33.1 mV
14.0 mV
12.4 mV
12.5 mV
Pass
70% Load
29.3 mV
15.3 mV
13.2 mV
13.5 mV
Pass
80% Load
29.7 mV
16.2 mV
14.9 mV
14.2 mV
Pass
90% Load
31.2 mV
17.5 mV
14.6 mV
16.1 mV
Pass
100% Load
47.1 mV
18.8 mV
16.0 mV
15.7 mV
Pass
110% Load
49.9 mV
19.6 mV
18.3 mV
16.7 mV
Pass
Crossload 1
35.3 mV
14.8 mV
15.6 mV
17.3 mV
Pass
Crossload 2
46.0 mV
15.2 mV
12.7 mV
15.9 mV
Pass
The results above are not used in the certification process
Kolink Enclave 600W
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern