ErP Lot 6 2010: ✓
ErP Lot 6 2013: ✓
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.592%
Average Noise Output (>1450 Load Combinations)
32.29dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
62.188%
Standby Power Consumption
0.0932W
Non-Accredited
12V Ripple (Full Load)
46.66mV
5V Ripple (Full Load)
18.54mV
3.3V Ripple (Full Load)
30.05mV
5VSB Ripple (Full Load)
18.15mV
12V Load Regulation
1.01%
5V Load Regulation
1.84%
3.3V Load Regulation
2.84%
5VSB Load Regulation
3.57%
Inrush Current
26.613A
Accredited
Average Efficiency (>1450 load combinations)
90.886%
Average Noise Output (>1450 Load Combinations)
32.24dBA
Average PF (>1450 Load Combinations)
0.954
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1471W
Non-Accredited
12V Ripple (Full Load)
48.38mV
5V Ripple (Full Load)
18.30mV
3.3V Ripple (Full Load)
28.17mV
5VSB Ripple (Full Load)
19.74mV
12V Load Regulation
0.98%
5V Load Regulation
1.80%
3.3V Load Regulation
2.81%
5VSB Load Regulation
3.54%
Inrush Current
50.053A
Hold-Up Time & PWR_OK Signal
19.20ms
AC Loss to PWR_OK Hold Up Time
15.90ms
PWR_OK Inactive to DC Loss Delay
3.30ms
PSU Timings: T1 (20% / 100%)
88.0ms
81.0ms
PSU Timings: T3 (20% / 100%)
263.0ms
274.0ms
OPP (0.00°C / 0.00°C)
130.18%
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
19.2
AC Loss to PWR_OK Hold Up Time (ms)
15.9
PWR_OK Inactive to DC Loss Delay (ms)
3.3
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
70.122%
0.046
5.103V
0.328
115.15V
2
0.090A
0.460
74.675%
0.084
5.102V
0.616
115.15V
3
0.550A
2.800
78.519%
0.319
5.090V
3.566
115.16V
4
1.000A
5.079
79.359%
0.399
5.078V
6.400
115.16V
5
1.500A
7.598
79.278%
0.441
5.064V
9.584
115.15V
6
2.500A
12.594
79.317%
0.485
5.037V
15.878
115.15V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
58.524%
0.017
5.093V
0.393
230.24V
2
0.090A
0.459
66.234%
0.029
5.092V
0.693
230.24V
3
0.550A
2.795
74.613%
0.144
5.080V
3.746
230.24V
4
1.000A
5.069
77.366%
0.222
5.068V
6.552
230.23V
5
1.500A
7.583
78.038%
0.282
5.055V
9.717
230.24V
6
2.500A
12.571
78.407%
0.353
5.028V
16.033
230.24V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.360A
1.998A
1.977A
0.989A
74.485
85.317%
855
11.6
40.07°C
0.979
12.126V
5.010V
3.339V
5.059V
87.304
42.31°C
115.17V
2
9.782A
3.001A
2.971A
1.190A
149.397
89.195%
858
12.3
40.52°C
0.984
12.114V
5.001V
3.329V
5.042V
167.494
43.14°C
115.15V
3
15.611A
3.506A
3.460A
1.393A
224.921
90.194%
865
13.5
41.44°C
0.985
12.102V
4.993V
3.321V
5.025V
249.375
44.43°C
115.14V
4
21.380A
4.014A
3.986A
1.598A
299.694
90.263%
1369
23.0
41.89°C
0.990
12.090V
4.984V
3.312V
5.008V
332.022
45.31°C
115.15V
5
26.840A
5.027A
4.998A
1.803A
374.623
89.858%
2164
37.0
42.34°C
0.994
12.076V
4.973V
3.302V
4.992V
416.905
46.13°C
115.14V
6
32.309A
6.046A
6.017A
2.011A
449.556
89.343%
2327
38.3
42.84°C
0.995
12.063V
4.963V
3.291V
4.975V
503.180
47.02°C
115.15V
7
37.827A
7.068A
7.040A
2.220A
524.879
88.741%
2338
38.4
43.64°C
0.996
12.049V
4.953V
3.280V
4.956V
591.475
48.52°C
115.15V
8
43.356A
8.096A
8.076A
2.432A
600.207
87.950%
2351
38.6
44.16°C
0.997
12.035V
4.942V
3.269V
4.937V
682.440
49.55°C
115.15V
9
49.256A
8.620A
8.593A
2.437A
674.725
87.195%
2356
38.7
44.72°C
0.997
12.023V
4.932V
3.259V
4.925V
773.815
50.65°C
115.16V
10
55.174A
9.146A
9.142A
2.547A
749.855
86.246%
2365
38.8
45.42°C
0.997
12.010V
4.921V
3.249V
4.910V
869.441
51.80°C
115.17V
11
61.501A
9.165A
9.169A
2.553A
825.102
85.143%
2372
38.9
46.67°C
0.997
11.998V
4.911V
3.239V
4.898V
969.080
53.50°C
115.18V
CL1
0.150A
12.002A
12.000A
0.000A
101.641
83.130%
1680
28.9
42.88°C
0.989
12.098V
5.000V
3.318V
5.055V
122.268
46.02°C
115.16V
CL2
62.525A
1.003A
1.000A
1.000A
765.351
86.871%
2362
38.8
45.61°C
0.997
12.030V
4.925V
3.263V
4.972V
881.021
51.41°C
115.19V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.361A
1.998A
1.977A
0.989A
74.493
86.553%
858
12.3
40.34°C
0.819
12.125V
5.011V
3.339V
5.059V
86.066
42.78°C
230.35V
2
9.785A
3.001A
2.971A
1.190A
149.417
90.705%
862
12.8
40.46°C
0.920
12.112V
5.002V
3.329V
5.042V
164.728
43.28°C
230.35V
3
15.615A
3.507A
3.462A
1.393A
224.941
91.919%
869
14.7
41.33°C
0.952
12.100V
4.992V
3.320V
5.025V
244.716
44.65°C
230.36V
4
21.387A
4.015A
3.985A
1.597A
299.727
92.222%
1469
25.4
41.81°C
0.966
12.088V
4.983V
3.311V
5.009V
325.005
45.66°C
230.36V
5
26.846A
5.030A
4.998A
1.803A
374.652
92.085%
2003
35.3
41.96°C
0.975
12.074V
4.973V
3.301V
4.992V
406.854
46.26°C
230.36V
6
32.317A
6.047A
6.016A
2.011A
449.585
91.810%
2323
38.2
42.74°C
0.979
12.061V
4.963V
3.290V
4.975V
489.691
47.57°C
230.36V
7
37.833A
7.069A
7.043A
2.220A
524.914
91.463%
2338
38.4
43.23°C
0.984
12.048V
4.952V
3.279V
4.956V
573.911
48.33°C
230.36V
8
43.365A
8.098A
8.080A
2.431A
600.233
91.046%
2338
38.4
43.65°C
0.986
12.033V
4.941V
3.268V
4.938V
659.260
49.86°C
230.36V
9
49.267A
8.620A
8.592A
2.437A
674.750
90.622%
2347
38.6
44.96°C
0.987
12.021V
4.931V
3.259V
4.926V
744.577
51.78°C
230.35V
10
55.184A
9.150A
9.144A
2.546A
749.877
90.078%
2358
38.7
46.18°C
0.988
12.008V
4.921V
3.248V
4.910V
832.472
53.35°C
230.35V
11
61.506A
9.168A
9.170A
2.553A
825.111
89.523%
2364
38.8
46.51°C
0.989
11.997V
4.910V
3.239V
4.899V
921.679
54.16°C
230.35V
CL1
0.149A
12.001A
12.002A
0.000A
101.643
84.577%
1864
31.8
41.04°C
0.882
12.097V
5.001V
3.318V
5.055V
120.178
45.91°C
230.36V
CL2
62.525A
1.004A
1.001A
1.000A
765.232
90.761%
2351
38.6
45.91°C
0.988
12.028V
4.924V
3.262V
4.973V
843.132
52.98°C
230.35V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.195A
0.500A
0.477A
0.197A
19.609
67.466%
847
11.4
0.857
12.136V
5.015V
3.346V
5.092V
29.065
115.16V
2
2.451A
0.999A
0.985A
0.394A
40.041
78.736%
849
11.5
0.937
12.133V
5.013V
3.344V
5.082V
50.855
115.17V
3
3.634A
1.499A
1.465A
0.592A
59.486
83.366%
850
11.5
0.962
12.129V
5.011V
3.341V
5.073V
71.355
115.17V
4
4.892A
1.998A
1.974A
0.790A
79.914
85.885%
852
11.6
0.977
12.125V
5.009V
3.338V
5.064V
93.048
115.17V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.194A
0.499A
0.477A
0.197A
19.592
68.535%
847
11.4
0.560
12.135V
5.016V
3.347V
5.093V
28.587
230.35V
2
2.449A
0.999A
0.986A
0.394A
40.020
80.040%
850
11.5
0.699
12.132V
5.014V
3.345V
5.083V
50.000
230.35V
3
3.634A
1.498A
1.464A
0.592A
59.476
84.835%
852
11.6
0.780
12.128V
5.011V
3.342V
5.074V
70.108
230.35V
4
4.892A
1.998A
1.976A
0.790A
79.913
87.360%
853
11.6
0.829
12.123V
5.009V
3.339V
5.064V
91.476
230.35V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.4 mV
7.1 mV
15.3 mV
9.4 mV
Pass
20% Load
17.1 mV
7.7 mV
15.3 mV
9.3 mV
Pass
30% Load
20.1 mV
8.9 mV
15.8 mV
10.7 mV
Pass
40% Load
18.0 mV
9.9 mV
17.9 mV
12.9 mV
Pass
50% Load
21.3 mV
11.5 mV
18.5 mV
13.3 mV
Pass
60% Load
23.6 mV
12.8 mV
19.8 mV
13.4 mV
Pass
70% Load
27.0 mV
13.8 mV
22.2 mV
13.7 mV
Pass
80% Load
28.6 mV
15.0 mV
24.9 mV
15.1 mV
Pass
90% Load
31.9 mV
16.0 mV
25.3 mV
14.7 mV
Pass
100% Load
46.7 mV
18.5 mV
30.1 mV
18.2 mV
Pass
110% Load
53.0 mV
19.7 mV
28.7 mV
19.0 mV
Pass
Crossload 1
18.4 mV
8.3 mV
22.3 mV
23.8 mV
Pass
Crossload 2
48.5 mV
17.1 mV
23.6 mV
17.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.5 mV
6.8 mV
13.6 mV
9.6 mV
Pass
20% Load
18.3 mV
7.3 mV
15.2 mV
9.9 mV
Pass
30% Load
21.8 mV
8.5 mV
14.7 mV
12.3 mV
Pass
40% Load
18.2 mV
10.5 mV
16.2 mV
14.1 mV
Pass
50% Load
20.7 mV
11.7 mV
17.7 mV
12.2 mV
Pass
60% Load
24.5 mV
12.2 mV
19.3 mV
13.1 mV
Pass
70% Load
26.3 mV
13.3 mV
20.7 mV
14.6 mV
Pass
80% Load
29.4 mV
14.9 mV
25.1 mV
14.6 mV
Pass
90% Load
31.8 mV
15.6 mV
25.5 mV
15.5 mV
Pass
100% Load
48.4 mV
18.3 mV
28.2 mV
19.7 mV
Pass
110% Load
54.6 mV
20.1 mV
30.0 mV
19.8 mV
Pass
Crossload 1
21.1 mV
8.2 mV
22.7 mV
23.0 mV
Pass
Crossload 2
50.9 mV
17.1 mV
24.1 mV
17.5 mV
Pass
The results above are not used in the certification process
Cooler Master MWE Gold 750