1x ON Semiconductor MBR2045CTG SBR (45V, 20A @ 163°C)
Standby PWM Controller
Infineon ICE2QR4765
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
ErP Lot 6 2010: ✓
ErP Lot 6 2013: ✓
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.138%
Average Noise Output (>1450 Load Combinations)
35.29dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
61.102%
Standby Power Consumption
0.0891W
Non-Accredited
12V Ripple (Full Load)
51.27mV
5V Ripple (Full Load)
16.41mV
3.3V Ripple (Full Load)
21.17mV
5VSB Ripple (Full Load)
13.11mV
12V Load Regulation
0.88%
5V Load Regulation
1.69%
3.3V Load Regulation
2.60%
5VSB Load Regulation
3.01%
Inrush Current
32.742A
Accredited
Average Efficiency (>1450 load combinations)
90.259%
Average Noise Output (>1450 Load Combinations)
35.35dBA
Average PF (>1450 Load Combinations)
0.952
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1426W
Non-Accredited
12V Ripple (Full Load)
51.22mV
5V Ripple (Full Load)
16.65mV
3.3V Ripple (Full Load)
20.56mV
5VSB Ripple (Full Load)
12.81mV
12V Load Regulation
0.86%
5V Load Regulation
1.75%
3.3V Load Regulation
2.58%
5VSB Load Regulation
2.95%
Inrush Current
79.619A
Hold-Up Time & PWR_OK Signal
14.60ms
AC Loss to PWR_OK Hold Up Time
13.50ms
PWR_OK Inactive to DC Loss Delay
1.10ms
PSU Timings: T1 (20% / 100%)
80.0ms
84.0ms
PSU Timings: T3 (20% / 100%)
268.0ms
264.0ms
OPP (0.00°C / 0.00°C)
116.16%
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
14.6
AC Loss to PWR_OK Hold Up Time (ms)
13.5
PWR_OK Inactive to DC Loss Delay (ms)
1.1
待機電源消耗
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
70.769%
0.046
5.092V
0.325
115.11V
2
0.090A
0.459
75.493%
0.085
5.092V
0.608
115.11V
3
0.550A
2.794
79.420%
0.323
5.080V
3.518
115.11V
4
1.000A
5.068
78.549%
0.408
5.068V
6.452
115.11V
5
1.500A
7.582
78.399%
0.450
5.054V
9.671
115.11V
6
2.500A
12.570
78.460%
0.493
5.028V
16.021
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
58.524%
0.017
5.093V
0.393
230.24V
2
0.090A
0.459
66.234%
0.029
5.092V
0.693
230.24V
3
0.550A
2.795
74.613%
0.144
5.080V
3.746
230.24V
4
1.000A
5.069
77.366%
0.222
5.068V
6.552
230.23V
5
1.500A
7.583
78.038%
0.282
5.055V
9.717
230.24V
6
2.500A
12.571
78.407%
0.353
5.028V
16.033
230.24V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.572A
1.992A
1.979A
0.990A
64.918
84.036%
916
12.4
40.04°C
0.967
12.126V
5.022V
3.335V
5.052V
77.250
42.55°C
115.11V
2
8.130A
2.993A
2.977A
1.191A
129.399
88.440%
920
12.4
40.24°C
0.988
12.115V
5.013V
3.325V
5.038V
146.312
43.34°C
115.11V
3
13.093A
3.496A
3.466A
1.393A
194.487
89.595%
928
12.4
41.68°C
0.987
12.105V
5.005V
3.318V
5.024V
217.074
44.97°C
115.11V
4
18.066A
4.003A
3.987A
1.597A
259.714
89.691%
1856
31.7
42.24°C
0.991
12.095V
4.998V
3.310V
5.011V
289.565
46.21°C
115.11V
5
22.719A
5.012A
4.998A
1.802A
324.987
89.361%
2404
39.1
42.84°C
0.994
12.082V
4.988V
3.300V
4.996V
363.678
47.61°C
115.11V
6
27.317A
6.028A
6.017A
2.008A
389.508
88.937%
2416
39.2
43.01°C
0.995
12.069V
4.979V
3.291V
4.982V
437.959
48.19°C
115.11V
7
31.991A
7.046A
7.039A
2.215A
454.826
88.356%
2428
39.4
43.22°C
0.996
12.057V
4.969V
3.281V
4.968V
514.767
49.05°C
115.10V
8
36.671A
8.068A
8.073A
2.424A
520.121
87.617%
2435
39.5
44.68°C
0.997
12.045V
4.959V
3.271V
4.952V
593.628
51.00°C
115.10V
9
41.759A
8.586A
8.582A
2.429A
585.028
86.838%
2437
39.5
45.53°C
0.997
12.034V
4.950V
3.262V
4.942V
673.699
52.55°C
115.10V
10
46.789A
9.109A
9.129A
2.536A
649.759
85.835%
2407
39.1
46.09°C
0.997
12.023V
4.942V
3.253V
4.930V
756.989
53.78°C
115.10V
11
52.227A
9.123A
9.152A
2.541A
714.570
84.585%
2400
39.1
46.53°C
0.998
12.012V
4.934V
3.245V
4.922V
844.798
55.16°C
115.10V
CL1
0.144A
11.999A
11.999A
0.000A
101.335
83.257%
1818
31.2
42.96°C
0.990
12.103V
4.993V
3.307V
5.052V
121.713
47.12°C
115.12V
CL2
54.097A
1.001A
0.999A
1.000A
664.439
86.461%
2400
39.1
45.88°C
0.997
12.038V
4.961V
3.272V
4.986V
768.484
53.18°C
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.576A
1.993A
1.978A
0.990A
64.956
85.189%
917
12.4
40.21°C
0.788
12.125V
5.017V
3.335V
5.052V
76.249
42.47°C
230.25V
2
8.134A
2.996A
2.975A
1.191A
129.439
89.853%
921
12.4
40.85°C
0.911
12.115V
5.008V
3.325V
5.038V
144.057
43.58°C
230.25V
3
13.097A
3.500A
3.467A
1.393A
194.525
91.207%
927
12.4
41.00°C
0.949
12.104V
5.000V
3.317V
5.024V
213.278
44.36°C
230.26V
4
18.073A
4.008A
3.987A
1.597A
259.760
91.583%
1585
28.3
41.78°C
0.964
12.093V
4.992V
3.309V
5.011V
283.632
45.53°C
230.25V
5
22.725A
5.019A
5.001A
1.801A
325.031
91.420%
2399
39.1
42.05°C
0.977
12.080V
4.983V
3.300V
4.997V
355.535
46.26°C
230.25V
6
27.324A
6.037A
6.019A
2.007A
389.546
91.207%
2414
39.2
42.79°C
0.980
12.067V
4.973V
3.290V
4.984V
427.100
47.64°C
230.25V
7
31.997A
7.054A
7.045A
2.215A
454.876
90.867%
2429
39.4
43.68°C
0.985
12.056V
4.963V
3.280V
4.968V
500.593
49.06°C
230.25V
8
36.681A
8.079A
8.075A
2.424A
520.173
90.400%
2438
39.5
43.81°C
0.986
12.043V
4.953V
3.270V
4.952V
575.410
49.70°C
230.25V
9
41.766A
8.598A
8.588A
2.429A
585.099
89.912%
2444
39.5
44.49°C
0.987
12.033V
4.945V
3.261V
4.943V
650.746
51.00°C
230.25V
10
46.802A
9.123A
9.132A
2.536A
649.831
89.255%
2447
39.6
45.23°C
0.988
12.021V
4.935V
3.252V
4.931V
728.065
52.45°C
230.26V
11
52.242A
9.135A
9.155A
2.541A
714.649
88.357%
2450
39.6
46.66°C
0.989
12.010V
4.928V
3.244V
4.922V
808.822
55.35°C
230.26V
CL1
0.147A
12.003A
11.999A
0.000A
101.330
84.577%
1696
29.3
42.45°C
0.876
12.102V
4.988V
3.307V
5.053V
119.808
46.58°C
230.26V
CL2
54.100A
1.003A
0.999A
1.000A
664.426
89.934%
2447
39.6
45.48°C
0.988
12.037V
4.955V
3.271V
4.986V
738.797
52.46°C
230.26V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.198A
0.495A
0.479A
0.197A
19.626
68.738%
903
12.7
0.820
12.132V
5.030V
3.342V
5.083V
28.552
115.12V
2
2.448A
0.995A
0.988A
0.394A
39.996
79.535%
909
12.5
0.927
12.130V
5.027V
3.340V
5.074V
50.287
115.12V
3
3.637A
1.492A
1.469A
0.593A
59.507
83.434%
913
12.4
0.959
12.127V
5.024V
3.337V
5.065V
71.322
115.12V
4
4.890A
1.992A
1.982A
0.791A
79.894
85.840%
915
12.4
0.974
12.124V
5.021V
3.333V
5.056V
93.073
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.498A
0.478A
0.197A
19.664
69.835%
910
12.5
0.542
12.134V
5.028V
3.342V
5.081V
28.158
230.26V
2
2.451A
0.996A
0.988A
0.394A
40.032
80.622%
911
12.5
0.677
12.129V
5.025V
3.340V
5.073V
49.654
230.25V
3
3.640A
1.495A
1.469A
0.593A
59.549
84.771%
913
12.4
0.766
12.126V
5.019V
3.337V
5.065V
70.247
230.26V
4
4.895A
1.993A
1.981A
0.791A
79.941
87.258%
915
12.4
0.830
12.123V
5.016V
3.333V
5.056V
91.615
230.26V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.8 mV
6.5 mV
6.8 mV
6.0 mV
Pass
20% Load
16.5 mV
7.5 mV
7.8 mV
6.5 mV
Pass
30% Load
19.3 mV
8.5 mV
8.8 mV
7.5 mV
Pass
40% Load
18.6 mV
9.3 mV
10.2 mV
9.6 mV
Pass
50% Load
20.7 mV
10.1 mV
11.4 mV
10.1 mV
Pass
60% Load
24.1 mV
10.9 mV
13.2 mV
9.8 mV
Pass
70% Load
27.3 mV
12.2 mV
15.9 mV
10.8 mV
Pass
80% Load
30.0 mV
13.6 mV
16.4 mV
11.4 mV
Pass
90% Load
32.6 mV
14.0 mV
17.7 mV
11.7 mV
Pass
100% Load
51.3 mV
16.4 mV
21.2 mV
13.1 mV
Pass
110% Load
55.1 mV
17.0 mV
20.8 mV
14.6 mV
Pass
Crossload 1
20.1 mV
9.6 mV
12.1 mV
21.0 mV
Pass
Crossload 2
51.8 mV
15.8 mV
17.2 mV
14.3 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.0 mV
7.0 mV
7.4 mV
6.3 mV
Pass
20% Load
16.6 mV
7.5 mV
7.7 mV
6.9 mV
Pass
30% Load
20.9 mV
8.2 mV
8.6 mV
8.3 mV
Pass
40% Load
18.0 mV
8.9 mV
10.3 mV
9.7 mV
Pass
50% Load
21.1 mV
10.2 mV
11.8 mV
10.1 mV
Pass
60% Load
23.7 mV
11.2 mV
13.3 mV
10.0 mV
Pass
70% Load
26.7 mV
12.5 mV
14.3 mV
11.1 mV
Pass
80% Load
29.2 mV
13.0 mV
16.6 mV
12.2 mV
Pass
90% Load
33.0 mV
13.9 mV
16.9 mV
13.3 mV
Pass
100% Load
51.2 mV
16.7 mV
20.6 mV
12.8 mV
Pass
110% Load
55.5 mV
16.9 mV
21.0 mV
13.7 mV
Pass
Crossload 1
22.2 mV
10.5 mV
12.4 mV
21.0 mV
Pass
Crossload 2
51.7 mV
14.6 mV
16.8 mV
12.8 mV
Pass
The results above are not used in the certification process