Cables and Connectors(Non-accredited measurements)
Native Cables
Description
Cable Count
Connector Count (Total)
Gauge
ATX connector 20+4 pin (600mm)
1
1
18-24AWG
Modular Cables
4+4 pin EPS12V (650mm)
2
2
18AWG
6+2 pin PCIe (600mm+100mm)
4
8
18AWG
SATA (550mm+100mm+100mm)
1
3
18AWG
4 pin Molex (550mm+100mm+100mm)
1
3
18AWG
FDD Adapter (+100mm)
1
2
22AWG
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
24
24
70.8
3
0.5
Watts
120
849.6
15
6
Total Max. Power (W)
850
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
88.715%
Average Noise Output (>1450 Load Combinations)
24.63dBA
Average PF (>1450 Load Combinations)
0.984
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1069W
Non-Accredited
12V Ripple (Full Load)
21.69mV
5V Ripple (Full Load)
19.28mV
3.3V Ripple (Full Load)
22.06mV
5VSB Ripple (Full Load)
32.69mV
12V Load Regulation
1.05%
5V Load Regulation
0.80%
3.3V Load Regulation
1.39%
5VSB Load Regulation
3.42%
Inrush Current
22.587A
Accredited
Average Efficiency (>1450 load combinations)
90.709%
Average Noise Output (>1450 Load Combinations)
30.05dBA
Average PF (>1450 Load Combinations)
0.964
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.1962W
Non-Accredited
12V Ripple (Full Load)
17.44mV
5V Ripple (Full Load)
22.37mV
3.3V Ripple (Full Load)
17.25mV
5VSB Ripple (Full Load)
26.63mV
12V Load Regulation
0.52%
5V Load Regulation
0.36%
3.3V Load Regulation
0.79%
5VSB Load Regulation
2.97%
Inrush Current
47.130A
Hold-Up Time & PWR_OK Signal
28.24ms
AC Loss to PWR_OK Hold Up Time
24.06ms
PWR_OK Inactive to DC Loss Delay
4.18ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
28.24
AC Loss to PWR_OK Hold Up Time (ms)
24.06
PWR_OK Inactive to DC Loss Delay (ms)
4.18
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
62.602%
0.031
5.129V
0.369
115.37V
2
0.090A
0.462
72.300%
0.052
5.127V
0.639
115.38V
3
0.550A
2.813
79.847%
0.236
5.113V
3.523
115.37V
4
1.000A
5.100
80.138%
0.338
5.099V
6.364
115.37V
5
1.500A
7.627
79.747%
0.401
5.084V
9.564
115.36V
6
3.000A
15.114
77.385%
0.481
5.038V
19.531
115.35V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
50.000%
0.014
5.128V
0.462
230.92V
2
0.090A
0.462
63.724%
0.021
5.127V
0.725
230.92V
3
0.550A
2.813
78.751%
0.099
5.113V
3.572
230.92V
4
1.000A
5.099
79.436%
0.166
5.098V
6.419
230.92V
5
1.500A
7.628
79.186%
0.227
5.084V
9.633
230.92V
6
3.000A
15.116
78.799%
0.337
5.038V
19.183
230.91V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.235A
1.994A
2.000A
0.981A
84.823
84.781%
520
11.8
37.77°C
0.975
12.083V
5.005V
3.299V
5.087V
100.050
40.96°C
115.02V
2
11.518A
2.994A
3.004A
1.179A
169.695
88.983%
520
11.8
37.98°C
0.989
12.055V
5.000V
3.294V
5.072V
190.704
41.49°C
115.02V
3
18.170A
3.507A
3.523A
1.380A
254.969
90.384%
520
11.8
38.50°C
0.991
12.046V
4.996V
3.290V
5.059V
282.096
42.36°C
115.03V
4
24.828A
4.004A
4.014A
1.583A
339.795
90.782%
520
11.8
38.99°C
0.995
12.028V
4.991V
3.287V
5.045V
374.299
43.79°C
115.03V
5
31.127A
5.007A
5.025A
1.787A
424.698
90.685%
725
18.5
39.73°C
0.997
12.023V
4.988V
3.282V
5.031V
468.321
44.73°C
115.13V
6
37.461A
6.019A
6.043A
1.991A
509.688
90.296%
998
27.9
40.53°C
0.998
12.010V
4.984V
3.276V
5.015V
564.466
45.63°C
115.05V
7
43.794A
7.025A
7.060A
2.199A
594.627
89.666%
1320
34.2
41.58°C
0.999
12.001V
4.978V
3.271V
4.998V
663.158
46.90°C
115.04V
8
50.126A
8.045A
8.081A
2.405A
679.613
88.853%
1600
39.9
42.71°C
0.999
11.994V
4.974V
3.267V
4.983V
764.873
48.18°C
115.08V
9
56.915A
8.547A
8.612A
2.411A
764.652
88.292%
1690
41.6
43.97°C
0.999
11.984V
4.971V
3.263V
4.975V
866.051
50.19°C
115.06V
10
63.436A
9.063A
9.110A
3.031A
849.487
87.542%
1690
41.6
45.43°C
0.998
11.977V
4.969V
3.259V
4.946V
970.374
52.13°C
115.04V
11
70.594A
9.064A
9.120A
3.034A
934.422
86.841%
1690
41.6
46.60°C
0.998
11.966V
4.967V
3.255V
4.940V
1076.019
53.83°C
115.06V
CL1
0.101A
14.024A
14.003A
0.004A
117.079
81.630%
700
17.6
42.64°C
0.982
12.071V
4.992V
3.273V
5.086V
143.426
46.79°C
115.06V
CL2
70.793A
1.002A
1.003A
1.002A
860.645
88.213%
1690
41.6
43.78°C
0.998
11.969V
4.981V
3.280V
5.032V
975.640
50.26°C
115.06V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.224A
1.993A
1.994A
0.982A
84.576
85.355%
680
16.9
37.98°C
0.696
12.060V
5.010V
3.305V
5.091V
99.087
43.21°C
230.65V
2
11.485A
2.993A
2.994A
1.182A
169.101
89.709%
680
16.9
38.48°C
0.948
12.035V
5.008V
3.303V
5.078V
188.500
43.84°C
230.59V
3
18.129A
3.494A
3.482A
1.382A
254.188
91.424%
725
18.5
39.38°C
0.971
12.036V
5.007V
3.300V
5.066V
278.033
45.17°C
230.63V
4
24.791A
3.994A
4.000A
1.583A
339.391
92.083%
965
27.3
40.44°C
0.981
12.029V
5.005V
3.298V
5.053V
368.571
46.62°C
230.57V
5
31.122A
4.995A
5.006A
1.786A
424.697
92.239%
1230
32.8
41.10°C
0.986
12.024V
5.003V
3.295V
5.040V
460.433
47.54°C
230.49V
6
37.378A
5.999A
6.013A
1.989A
509.229
92.226%
1445
39.2
41.61°C
0.990
12.024V
5.001V
3.292V
5.028V
552.156
48.44°C
230.44V
7
43.724A
6.999A
7.023A
2.194A
594.562
91.927%
1752
43.0
42.91°C
0.993
12.018V
4.999V
3.289V
5.014V
646.774
49.98°C
230.30V
8
50.050A
8.002A
8.031A
2.400A
679.895
91.636%
1835
44.4
44.16°C
0.994
12.018V
4.998V
3.287V
5.001V
741.949
51.75°C
230.40V
9
56.780A
8.505A
8.524A
2.403A
764.819
91.376%
1835
44.4
44.78°C
0.995
12.017V
4.997V
3.284V
4.994V
836.998
52.78°C
230.34V
10
63.252A
9.008A
9.046A
3.020A
849.659
90.965%
1835
44.4
45.34°C
0.995
12.015V
4.995V
3.282V
4.968V
934.046
53.98°C
230.27V
11
70.313A
9.008A
9.052A
3.024A
934.431
90.576%
1835
44.4
46.36°C
0.996
12.014V
4.995V
3.280V
4.962V
1031.649
55.68°C
230.30V
CL1
0.724A
14.000A
13.997A
0.000A
125.023
83.257%
1240
33.6
43.68°C
0.929
12.047V
5.009V
3.299V
5.094V
150.166
48.51°C
230.80V
CL2
70.829A
0.999A
0.996A
1.000A
864.251
91.447%
1835
44.4
45.19°C
0.996
12.014V
4.998V
3.287V
5.045V
945.084
52.40°C
230.37V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.211A
0.489A
0.480A
0.196A
19.701
65.633%
0
<6.0
0.652
12.107V
5.009V
3.304V
5.121V
30.017
115.00V
2
2.441A
0.989A
0.997A
0.391A
39.794
77.592%
0
<6.0
0.715
12.104V
5.009V
3.305V
5.112V
51.286
115.00V
3
3.674A
1.485A
1.515A
0.586A
59.870
82.118%
520
11.8
0.775
12.097V
5.007V
3.301V
5.101V
72.907
115.02V
4
4.903A
1.994A
2.000A
0.785A
79.832
84.419%
520
11.8
0.972
12.085V
5.007V
3.299V
5.093V
94.566
115.02V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.207A
0.491A
0.481A
0.196A
19.659
64.905%
680
16.9
0.433
12.089V
5.012V
3.305V
5.120V
30.289
230.25V
2
2.444A
0.990A
0.997A
0.391A
39.769
77.248%
680
16.9
0.536
12.085V
5.010V
3.304V
5.111V
51.482
230.26V
3
3.679A
1.486A
1.513A
0.586A
59.854
82.321%
680
16.9
0.685
12.077V
5.009V
3.302V
5.101V
72.708
230.24V
4
4.912A
1.995A
1.999A
0.785A
79.794
85.025%
680
16.9
0.701
12.060V
5.007V
3.299V
5.093V
93.848
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.4 mV
10.5 mV
13.5 mV
22.6 mV
Pass
20% Load
13.9 mV
11.2 mV
14.5 mV
27.8 mV
Pass
30% Load
13.4 mV
12.2 mV
14.8 mV
18.4 mV
Pass
40% Load
14.2 mV
12.1 mV
15.7 mV
18.7 mV
Pass
50% Load
14.8 mV
13.8 mV
15.6 mV
21.8 mV
Pass
60% Load
15.4 mV
13.9 mV
15.6 mV
23.2 mV
Pass
70% Load
16.9 mV
15.5 mV
17.0 mV
27.5 mV
Pass
80% Load
18.7 mV
16.5 mV
18.7 mV
30.4 mV
Pass
90% Load
18.5 mV
17.6 mV
20.5 mV
31.0 mV
Pass
100% Load
21.7 mV
19.3 mV
22.1 mV
32.7 mV
Pass
110% Load
23.0 mV
21.9 mV
25.1 mV
35.1 mV
Pass
Crossload 1
10.3 mV
12.2 mV
14.1 mV
15.6 mV
Pass
Crossload 2
21.0 mV
18.6 mV
21.9 mV
29.7 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.0 mV
9.6 mV
9.3 mV
16.0 mV
Pass
20% Load
23.7 mV
10.5 mV
10.3 mV
17.6 mV
Pass
30% Load
26.9 mV
11.5 mV
11.1 mV
19.7 mV
Pass
40% Load
27.9 mV
13.2 mV
15.8 mV
19.7 mV
Pass
50% Load
31.0 mV
15.0 mV
17.7 mV
20.1 mV
Pass
60% Load
37.7 mV
17.3 mV
34.0 mV
21.8 mV
Pass
70% Load
36.5 mV
19.7 mV
16.9 mV
32.1 mV
Pass
80% Load
39.2 mV
21.4 mV
17.9 mV
27.9 mV
Pass
90% Load
41.0 mV
23.9 mV
28.2 mV
30.1 mV
Pass
100% Load
45.1 mV
29.9 mV
33.9 mV
28.4 mV
Pass
110% Load
47.2 mV
31.7 mV
39.7 mV
30.2 mV
Pass
Crossload 1
36.2 mV
17.4 mV
11.9 mV
15.1 mV
Pass
Crossload 2
37.4 mV
26.8 mV
38.9 mV
33.9 mV
Pass
The results above are not used in the certification process
EVGA 850 GQ
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern