CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Cooler Master MWE Gold 850 V2 (GX Gold 750) (#2)
Serial Number
Lab IDCM85002259
Certification ID252259
  • Test Result Report ID: 23PS2259A
  • Certificate Issue Date: Oct 13, 2023
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Power Specifications

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

待機電源消耗

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

8283848586878889909192Average efficiency (%)83.6289.5290.0289.2587.8384.9691.0191.9691.7290.940-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 82115V230V
8283848586878889909192Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 82115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0.9690.9820.9920.9960.9970.8490.9460.9710.9820.9860-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %228 / 22883.62%84.96%0.9690.849
20-<40 %331 / 33189.52%91.01%0.9820.946
40-<60 %327 / 32790.02%91.96%0.9920.971
60-<80 %333 / 33389.25%91.72%0.9960.982
80-100 %334 / 33487.83%90.94%0.9970.986
70-100 % (High-Load)505 / 50588.22%91.17%0.9970.985
All (published average)1553 / 155388.34%90.46%0.9890.954

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1553 (115V) and 1553 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 850 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 36.1 dB(A) at 115V and 36.2 dB(A) at 230V · loudest point 43.6 dB(A)
Efficiency 88.22% / 91.17% · power factor 0.997 / 0.985 (115V / 230V)
051015202530354045Average noise (dB(A))22.223.30-<20 %fan off 0%/0%22.723.320-<40 %fan off 0%/0%23.323.340-<60 %fan off 0%/0%23.423.460-<80 %fan off 0%/0%37.937.980-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))22.223.30-<20 %off 0%/0%22.723.320-<40 %off 0%/0%23.323.340-<60 %off 0%/0%23.423.460-<80 %off 0%/0%37.937.980-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %22.2 (23.3)23.3 (23.3)0% / 0%
20-<40 %22.7 (23.3)23.3 (23.3)0% / 0%
40-<60 %23.3 (23.3)23.3 (23.3)0% / 0%
60-<80 %23.4 (28.6)23.4 (31.5)0% / 0%
80-100 %37.9 (43.6)37.9 (43.6)0% / 0%
70-100 % (High-Load)36.1 (43.6)36.2 (43.6)0% / 0%
All (published average)31.7 (43.6)31.8 (43.6)0% / 0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1553 (115V) and 1553 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 850 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%1010 RPM · 23.5 dB(A) · 40.2 °C1010 RPM · 23.5 dB(A) · 40.2 °C+0.0 dB(A)
20%1011 RPM · 23.6 dB(A) · 40.4 °C1011 RPM · 23.6 dB(A) · 40.4 °C+0.0 dB(A)
50%1016 RPM · 23.7 dB(A) · 42.1 °C1016 RPM · 23.7 dB(A) · 42.1 °C+0.0 dB(A)
100%2135 RPM · 44.5 dB(A) · 45.3 °C2135 RPM · 44.5 dB(A) · 45.3 °C+0.0 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%1006 RPM · 24.4 dB(A) · 40.3 °C1006 RPM · 24.4 dB(A) · 40.3 °C+0.0 dB(A)
20%1008 RPM · 23.5 dB(A) · 40.7 °C1008 RPM · 23.5 dB(A) · 40.7 °C+0.0 dB(A)
50%1016 RPM · 23.7 dB(A) · 42.1 °C1016 RPM · 23.7 dB(A) · 42.1 °C+0.0 dB(A)
100%2131 RPM · 44.4 dB(A) · 45.7 °C2131 RPM · 44.4 dB(A) · 45.7 °C+0.0 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Cooler Master MWE Gold 850 V2 (GX Gold 750) (#2)

Top side
Top side
Power specifications label
Power specifications label
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus