CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Cougar GEX PRO 850
Serial Number12BD07GXP8500003
Lab IDCG85002581
Certification ID252581
  • Test Result Report ID: 24PS2581A
  • Certificate Issue Date: Sep 26, 2024
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

待機電源消耗

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%417 RPM · <6.0 dB(A) · 30.8 °C435 RPM · 6.8 dB(A) · 40.0 °C<6.0 → 6.8 dB(A)
20%420 RPM · 6.5 dB(A) · 30.5 °C438 RPM · 6.8 dB(A) · 40.5 °C+0.3 dB(A)
50%429 RPM · 6.8 dB(A) · 31.0 °C454 RPM · 7.0 dB(A) · 42.0 °C+0.2 dB(A)
100%1276 RPM · 31.0 dB(A) · 30.2 °C1704 RPM · 39.5 dB(A) · 45.9 °C+8.5 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%417 RPM · <6.0 dB(A) · 31.0 °C443 RPM · 6.6 dB(A) · 40.0 °C<6.0 → 6.6 dB(A)
20%419 RPM · <6.0 dB(A) · 30.3 °C445 RPM · 6.5 dB(A) · 40.8 °C<6.0 → 6.5 dB(A)
50%427 RPM · 6.8 dB(A) · 30.5 °C460 RPM · 6.8 dB(A) · 42.5 °C+0.0 dB(A)
100%1362 RPM · 33.0 dB(A) · 31.0 °C1704 RPM · 39.5 dB(A) · 45.6 °C+6.5 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Cougar GEX PRO 850

Top side
Top side
Power specifications label
Power specifications label
Cybenetics 提供自願性認證方案:電源供應器方面有 ETA(效率)、LAMBDA(噪音)與 SAFE(安全與正確運作);散熱產品方面有 DELTA(機殼隔音)與 PHI(風扇風量與靜壓)