CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Cougar GEX PRO 850
Serial Number12BD07GXP8500003
Lab IDCG85002581
Certification ID252581
  • Test Result Report ID: 24PS2581A
  • Certificate Issue Date: Sep 26, 2024
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%417 RPM · <6.0 dB(A) · 30.8 °C435 RPM · 6.8 dB(A) · 40.0 °C<6.0 → 6.8 dB(A)
20%420 RPM · 6.5 dB(A) · 30.5 °C438 RPM · 6.8 dB(A) · 40.5 °C+0.3 dB(A)
50%429 RPM · 6.8 dB(A) · 31.0 °C454 RPM · 7.0 dB(A) · 42.0 °C+0.2 dB(A)
100%1276 RPM · 31.0 dB(A) · 30.2 °C1704 RPM · 39.5 dB(A) · 45.9 °C+8.5 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%417 RPM · <6.0 dB(A) · 31.0 °C443 RPM · 6.6 dB(A) · 40.0 °C<6.0 → 6.6 dB(A)
20%419 RPM · <6.0 dB(A) · 30.3 °C445 RPM · 6.5 dB(A) · 40.8 °C<6.0 → 6.5 dB(A)
50%427 RPM · 6.8 dB(A) · 30.5 °C460 RPM · 6.8 dB(A) · 42.5 °C+0.0 dB(A)
100%1362 RPM · 33.0 dB(A) · 31.0 °C1704 RPM · 39.5 dB(A) · 45.6 °C+6.5 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Cougar GEX PRO 850

Top side
Top side
Power specifications label
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern