76.60A (141.59%), 11.575V* *Didn't shut down, Voltage drop (10.921V@77A)
72.60A (134.20%), 11.916V
5V OCP (29.3°C / 44.4°C)
26.5A (147.22%), 4.938V
26.6A (147.78%), 4.936V
3.3V OCP (29.3°C / 44.4°C)
25.7A (142.78%), 3.223V
26.2A (145.56%), 3.219V
5VSB OCP (29.3°C / 44.4°C)
3.9A (130.00%), 4.943V
3.8A (126.67%), 4.935V
OPP (30.84°C / 44.13°C)
136.86%
123.16%
保持时间 & PG信号
Hold-Up Time (ms)
16.5
AC Loss to PWR_OK Hold Up Time (ms)
14.2
PWR_OK Inactive to DC Loss Delay (ms)
2.3
待机电源
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.02 V
230.90 V
227.70 V
231.09 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.117 W
0.069 W
N/A
0.185 W
N/A
N/A
Apparent Power:
26.370 W
25.254 W
N/A
27.576 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs 230V
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
230V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input