Aristeidis Bitziopoulos, Certification Body General Manager
General Information
Main Specs
Product Identification Details
Brand
Gamemax
Model
GX-1050 PRO
OEM
Sohoo
Serial Number
Product Specifications
Manufacturer
Rated Voltage (Vrms)
100-240
Rated Current (Arms)
15-8
Rated Frequency (Hz)
50-60
Rated Power (W)
1050
Operating Temperature (Continuous Full Load) (°C)
Type
ATX12V
Cable Design
Fully Modular
Warranty
-
Cybenetics
Dimensions (W x H x D)
Weight
Cooling
135mm Hydro Dynamic Bearing Fan (DF1352512FDHN)
Semi-Passive Operation
✓
Cybenetics Testing Information
Lab ID
GM10502654
Date of receipt
Nov 5, 2024
Testing Date
Nov 19, 2024
Report Issued Date
Nov 20, 2024
DUT Notes
No -12V Rail, despite the label saying it has one. During OCP testing under normal and cold conditions, the +12V rail reached 127A (>145% load) without shutting down. This forces us to not provide an ATX v3.1 compliance.
Engineer Name
-
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input