CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Gamemax GX-1050 PRO
Serial Number
Lab IDGM10502654
Certification ID252654
  • Test Result Report ID: 24PS2654A
  • Certificate Issue Date: Nov 20, 2024
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 30.2 °C427 RPM · 7.7 dB(A) · 40.3 °Cfan starts (<6.0 → 7.7)
20%0 RPM · <6.0 dB(A) · 32.9 °C631 RPM · 17.6 dB(A) · 40.9 °Cfan starts (<6.0 → 17.6)
50%0 RPM · <6.0 dB(A) · 35.4 °C991 RPM · 25.8 dB(A) · 42.4 °Cfan starts (<6.0 → 25.8)
100%1095 RPM · 28.6 dB(A) · 30.2 °C1435 RPM · 36.0 dB(A) · 45.1 °C+7.4 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%216 RPM · <6.0 dB(A) · 30.4 °C415 RPM · 7.5 dB(A) · 40.4 °C<6.0 → 7.5 dB(A)
20%280 RPM · <6.0 dB(A) · 30.8 °C611 RPM · 14.5 dB(A) · 40.8 °C<6.0 → 14.5 dB(A)
50%632 RPM · 17.6 dB(A) · 31.2 °C984 RPM · 26.1 dB(A) · 42.1 °C+8.5 dB(A)
100%1192 RPM · 30.9 dB(A) · 30.7 °C1448 RPM · 36.5 dB(A) · 45.1 °C+5.6 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Gamemax GX-1050 PRO

Top side
Top side
Power specifications label
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus