77.20A (132.42%), 11.498V *High Ripple (175.43mV), Voltage Drop (11.266V@77.6A), Stopped
76.80A (131.73%), 11.412V *High Ripple(185.25mV), Voltage Drop (11.15V@77.2A), Stopped
5V OCP (28.4°C / 41.7°C)
27A (150.00%), 5.022V
25.6A (142.22%), 5.015V
3.3V OCP (28.4°C / 41.7°C)
28.5A (158.33%), 3.304V
28.1A (156.11%), 3.304V
5VSB OCP (28.4°C / 41.7°C)
5.5A (183.33%), 4.986V
5.3A (176.67%), 4.988V
OPP (29.27°C / 42.41°C)
127.23%
124.24%
Hold-Up Time (ms)
13.4
AC Loss to PWR_OK Hold Up Time (ms)
12.1
PWR_OK Inactive to DC Loss Delay (ms)
1.3
待機電源消耗
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.00 V
230.88 V
227.70 V
231.07 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.29 %
2.00 %
PASS
Real Power:
0.159 W
0.120 W
N/A
0.212 W
N/A
N/A
Apparent Power:
16.358 W
16.154 W
N/A
16.602 W
N/A
N/A
Power Factor:
0.011
N/A
N/A
N/A
N/A
N/A
Graphs 230V
230V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
230V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input