CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Seasonic Core GX-750 ATX3
Serial Number-
Lab IDSS75002753
Certification ID252753
  • Test Result Report ID: 25PS2753A
  • Certificate Issue Date: Mar 6, 2025
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features(Manufacturer)

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%845 RPM · 26.0 dB(A) · 30.3 °C864 RPM · 24.9 dB(A) · 40.4 °C-1.1 dB(A)
20%845 RPM · 26.0 dB(A) · 30.3 °C862 RPM · 24.7 dB(A) · 40.6 °C-1.3 dB(A)
50%830 RPM · 24.5 dB(A) · 30.1 °C843 RPM · 26.0 dB(A) · 42.2 °C+1.5 dB(A)
100%1498 RPM · 40.0 dB(A) · 30.4 °C1583 RPM · 42.3 dB(A) · 45.5 °C+2.3 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%851 RPM · 25.7 dB(A) · 30.2 °C864 RPM · 24.9 dB(A) · 40.2 °C-0.8 dB(A)
20%849 RPM · 25.9 dB(A) · 30.2 °C861 RPM · 24.6 dB(A) · 40.7 °C-1.3 dB(A)
50%832 RPM · 24.7 dB(A) · 30.6 °C842 RPM · 25.9 dB(A) · 42.4 °C+1.2 dB(A)
100%1502 RPM · 40.1 dB(A) · 30.4 °C1583 RPM · 42.3 dB(A) · 45.2 °C+2.2 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter, with the fan stopped; with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Seasonic Core GX-750 ATX3

Top side
Top side
Power specifications label
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern