CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Thermaltake Toughpower PT 1000W
Serial NumberPSTPP100FNFAPU1BLCW00008
Lab IDTT10002995
Certification ID252995
  • Test Result Report ID: 25PS2995A
  • Certificate Issue Date: Oct 22, 2025
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Stromverbrauch im Ruhezustand

Tables

Graphs

Efficiency Graph

Noise Graph

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%391 RPM · <6.0 dB(A) · 30.1 °C401 RPM · <6.0 dB(A) · 40.4 °C<6.0 in both
20%393 RPM · <6.0 dB(A) · 30.1 °C402 RPM · <6.0 dB(A) · 40.8 °C<6.0 in both
50%394 RPM · <6.0 dB(A) · 30.6 °C405 RPM · <6.0 dB(A) · 42.3 °C<6.0 in both
100%1038 RPM · 27.9 dB(A) · 30.6 °C1430 RPM · 36.3 dB(A) · 45.4 °C+8.4 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%390 RPM · <6.0 dB(A) · 30.6 °C401 RPM · <6.0 dB(A) · 40.1 °C<6.0 in both
20%392 RPM · <6.0 dB(A) · 30.0 °C403 RPM · <6.0 dB(A) · 40.8 °C<6.0 in both
50%393 RPM · <6.0 dB(A) · 30.5 °C404 RPM · <6.0 dB(A) · 42.4 °C<6.0 in both
100%1037 RPM · 27.8 dB(A) · 30.4 °C1434 RPM · 36.4 dB(A) · 45.9 °C+8.6 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

Thermaltake Toughpower PT 1000W

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern