CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
be quiet! Power Zone 2 1200W (EU)
序号030EUH5429900002
Lab IDBQ12003042
Certification ID253042
  • Test Result Report ID: 25PS3042A
  • Certificate Issue Date: Nov 21, 2025
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

线材与接头(Non-accredited measurements)

Protection Features

电源规范

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

保持时间 & PG信号

待机电源

Tables

Graphs

转换效率图表

Efficiency and power factor by load range

85868788899091929394Average efficiency (%)86.1191.6291.7891.0189.7386.9892.9893.4893.1492.390-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
85868788899091929394Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0.9580.9830.9920.9960.9970.8620.9490.9700.9780.9840-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %245 / 24586.11%86.98%0.9580.862
20-<40 %328 / 32891.62%92.98%0.9830.949
40-<60 %327 / 32791.78%93.48%0.9920.970
60-<80 %328 / 32891.01%93.14%0.9960.978
80-100 %331 / 33189.73%92.39%0.9970.984
70-100 % (High-Load)497 / 49790.08%92.60%0.9970.983
All (published average)1559 / 155990.26%92.05%0.9870.953

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1559 (115V) and 1559 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

噪音值图表

Noise by load range

High-Load Index (70-100 % load)
Noise 27.4 dB(A) at 115V and 27.4 dB(A) at 230V · loudest point 29.6 dB(A)
Efficiency 90.08% / 92.60% · power factor 0.997 / 0.983 (115V / 230V)
05101520253035Average noise (dB(A))<6.0<6.00-<20 %fan off 99%/99%13.314.720-<40 %fan off 94%/91%22.121.840-<60 %fan off 44%/45%25.225.260-<80 %fan off 0%/0%28.128.180-100 %fan off 0%/0%115V230V
0102030Average noise (dB(A))<6.0<6.00-<20 %off 99%/99%13.314.720-<40 %off 94%/91%22.121.840-<60 %off 44%/45%25.225.260-<80 %off 0%/0%28.128.180-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %<6.0 (<6.0)<6.0 (<6.0)99% / 99%
20-<40 %13.3 (24.8)14.7 (24.8)94% / 91%
40-<60 %22.1 (25.2)21.8 (25.2)44% / 45%
60-<80 %25.2 (26.6)25.2 (26.6)0% / 0%
80-100 %28.1 (29.6)28.1 (29.6)0% / 0%
70-100 % (High-Load)27.4 (29.6)27.4 (29.6)0% / 0%
All (published average)23.9 (29.6)23.9 (29.6)45% / 44%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1559 (115V) and 1559 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 34.2 °C0 RPM · <6.0 dB(A) · 45.8 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 35.3 °C0 RPM · <6.0 dB(A) · 48.0 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 37.8 °C1000 RPM · 25.2 dB(A) · 42.4 °Cfan starts (<6.0 → 25.2)
100%1097 RPM · 28.9 dB(A) · 30.1 °C1893 RPM · 44.0 dB(A) · 45.9 °C+15.1 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 32.3 °C0 RPM · <6.0 dB(A) · 45.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 34.4 °C0 RPM · <6.0 dB(A) · 46.8 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 37.2 °C1010 RPM · 25.7 dB(A) · 42.2 °Cfan starts (<6.0 → 25.7)
100%1131 RPM · 29.3 dB(A) · 30.3 °C1901 RPM · 43.9 dB(A) · 45.3 °C+14.6 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

高环温电源转换效率

5Vsb转换效率

输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

10-110%负载测试

20-80瓦负载测试

纹波测量

be quiet! Power Zone 2 1200W (EU)

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internal
PSU Internal
本测试报告中包含的所有数据和图表均可在以下条件下由任何人使用:使用过程需提及测试结果由Cybenetics提供。
在任何情况下都应提供原始测试结果文档的网站链接
Cybenetics 提供自愿性认证计划:电源方面有 ETA(效率)、LAMBDA(噪声)与 SAFE(安全与正确运行);散热产品方面有 DELTA(机箱隔音)与 PHI(风扇风量与静压)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus