CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
be quiet! Power Zone 2 1200W (EU)
Serial Number030EUH5429900002
Lab IDBQ12003042
Certification ID253042
  • Test Result Report ID: 25PS3042A
  • Certificate Issue Date: Nov 21, 2025
115V230V
Scheme: ETA-EMI PSU
115V230V
Scheme: LAMBDA PSU
Outside Validation Scope
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

DUT Information(Non-accredited measurements)

Cables and Connectors(Non-accredited measurements)

Protection Features

Power Specifications

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

Hold-Up Time & PWR_OK Signal

Vampire Power

Tables

Graphs

Efficiency Graph

Efficiency and power factor by load range

85868788899091929394Average efficiency (%)86.1191.6291.7891.0189.7386.9892.9893.4893.1492.390-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
85868788899091929394Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0.9580.9830.9920.9960.9970.8620.9490.9700.9780.9840-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %245 / 24586.11%86.98%0.9580.862
20-<40 %328 / 32891.62%92.98%0.9830.949
40-<60 %327 / 32791.78%93.48%0.9920.970
60-<80 %328 / 32891.01%93.14%0.9960.978
80-100 %331 / 33189.73%92.39%0.9970.984
70-100 % (High-Load)497 / 49790.08%92.60%0.9970.983
All (published average)1559 / 155990.26%92.05%0.9870.953

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1559 (115V) and 1559 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Noise Graph

Noise by load range

High-Load Index (70-100 % load)
Noise 27.4 dB(A) at 115V and 27.4 dB(A) at 230V · loudest point 29.6 dB(A)
Efficiency 90.08% / 92.60% · power factor 0.997 / 0.983 (115V / 230V)
05101520253035Average noise (dB(A))<6.0<6.00-<20 %fan off 99%/99%13.314.720-<40 %fan off 94%/91%22.121.840-<60 %fan off 44%/45%25.225.260-<80 %fan off 0%/0%28.128.180-100 %fan off 0%/0%115V230V
0102030Average noise (dB(A))<6.0<6.00-<20 %off 99%/99%13.314.720-<40 %off 94%/91%22.121.840-<60 %off 44%/45%25.225.260-<80 %off 0%/0%28.128.180-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %<6.0 (<6.0)<6.0 (<6.0)99% / 99%
20-<40 %13.3 (24.8)14.7 (24.8)94% / 91%
40-<60 %22.1 (25.2)21.8 (25.2)44% / 45%
60-<80 %25.2 (26.6)25.2 (26.6)0% / 0%
80-100 %28.1 (29.6)28.1 (29.6)0% / 0%
70-100 % (High-Load)27.4 (29.6)27.4 (29.6)0% / 0%
All (published average)23.9 (29.6)23.9 (29.6)45% / 44%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1559 (115V) and 1559 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 34.2 °C0 RPM · <6.0 dB(A) · 45.8 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 35.3 °C0 RPM · <6.0 dB(A) · 48.0 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 37.8 °C1000 RPM · 25.2 dB(A) · 42.4 °Cfan starts (<6.0 → 25.2)
100%1097 RPM · 28.9 dB(A) · 30.1 °C1893 RPM · 44.0 dB(A) · 45.9 °C+15.1 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 32.3 °C0 RPM · <6.0 dB(A) · 45.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 34.4 °C0 RPM · <6.0 dB(A) · 46.8 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 37.2 °C1010 RPM · 25.7 dB(A) · 42.2 °Cfan starts (<6.0 → 25.7)
100%1131 RPM · 29.3 dB(A) · 30.3 °C1901 RPM · 43.9 dB(A) · 45.3 °C+14.6 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

Efficiency under high ambient temperature

5VSB Efficiency

5VSB Efficiency (ERP LOT 3/6 & CEC)

Protection Features

Supplementary Tests (For Reference)

Typical Load Tests

Light Load Tests

Ripple Measurements

be quiet! Power Zone 2 1200W (EU)

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internal
PSU Internal
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure. THETA rates cooler performance on AMD AM5 and Intel LGA1851 outside ISO 17065 and accreditation scope