• The results apply to both the black and white (ICE) models.
• The vampire power consumption is too high for the Gold ETA rating at 230V (0.2127W).
• PF @ 230V is lower than the Platinum ETA level's requirements.
Engineer Name
Ioannis Kalyviotis
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Efficiency and power factor by load range
Load range
Points
Efficiency 115V
PF 115V
0-<20 %
210
86.05%
0.948
20-<40 %
310
90.29%
0.977
40-<60 %
310
90.55%
0.988
60-<80 %
310
89.85%
0.992
80-100 %
318
88.58%
0.994
70-100 % (High-Load)
473
88.91%
0.994
All (published average)
1458
89.27%
0.982
INFO
The average efficiency and power factor in five ranges of load. Calculated from the 1458 (115V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.
Informational. Not part of the ETA or LAMBDA rating.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Noise by load range
High-Load Index (70-100 % load)
Noise 39.3 dB(A) at 115V · loudest point 44.2 dB(A)
Efficiency 88.91% · power factor 0.994 (115V)
Load range
Noise 115V avg (loudest)
Fan off 115V
0-<20 %
15.2 (19.6)
35%
20-<40 %
20.6 (23.4)
0%
40-<60 %
26.1 (30.1)
0%
60-<80 %
31.9 (40.2)
0%
80-100 %
40.6 (44.2)
0%
70-100 % (High-Load)
39.3 (44.2)
0%
All (published average)
34.7 (44.2)
5%
INFO
The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1458 (115V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.
Informational. Not part of the ETA or LAMBDA rating.
Conducted Emissions EN 55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input