• The results apply to both the black and white (ICE) models.
• The vampire power consumption is too high for the Gold ETA rating at 230V (0.2127W).
• PF @ 230V is lower than the Platinum ETA level's requirements.
Engineer Name
Ioannis Kalyviotis
Authorized By the Laboratory Technical Manager
Aristeidis Bitziopoulos
Signature
Cables and Connectors(Non-accredited measurements)
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Efficiency and power factor by load range
Load range
Points
Efficiency 115V
PF 115V
0-<20 %
210
86.05%
0.948
20-<40 %
310
90.29%
0.977
40-<60 %
310
90.55%
0.988
60-<80 %
310
89.85%
0.992
80-100 %
318
88.58%
0.994
70-100 % (High-Load)
473
88.91%
0.994
All (published average)
1458
89.27%
0.982
INFO
The average efficiency and power factor in five ranges of load. Calculated from the 1458 (115V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.
Informational. Not part of the ETA or LAMBDA rating.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Noise by load range
High-Load Index (70-100 % load)
Noise 39.3 dB(A) at 115V · loudest point 44.2 dB(A)
Efficiency 88.91% · power factor 0.994 (115V)
Load range
Noise 115V avg (loudest)
Fan off 115V
0-<20 %
15.2 (19.6)
35%
20-<40 %
20.6 (23.4)
0%
40-<60 %
26.1 (30.1)
0%
60-<80 %
31.9 (40.2)
0%
80-100 %
40.6 (44.2)
0%
70-100 % (High-Load)
39.3 (44.2)
0%
All (published average)
34.7 (44.2)
5%
INFO
The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1458 (115V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.
Informational. Not part of the ETA or LAMBDA rating.
Conducted Emissions EN 55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
UVP (Full Load @ 90V)
✓
UVP (No Damage @ 80V)
✓
Conducted Emissions EN55032 & CISPR 32
✓
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.614A
1.977A
2.007A
1A
100.009
88.09%
739
21.1
40.43°C
0.965
11.855V
5.059V
3.288V
4.999V
113.531
42.3°C
115.01V
20%
14.268A
2.966A
3.012A
1.202A
199.962
91.039%
778
22.5
40.56°C
0.966
11.849V
5.057V
3.287V
4.992V
219.644
43.04°C
114.97V
30%
22.287A
3.465A
3.516A
1.404A
300.022
91.138%
875
26.3
41.15°C
0.979
11.844V
5.051V
3.285V
4.985V
329.189
45.88°C
114.94V
40%
30.273A
3.964A
4.02A
1.607A
399.598
91.207%
962
29.2
41.92°C
0.985
11.839V
5.046V
3.284V
4.978V
438.12
46.62°C
114.9V
50%
37.929A
4.957A
5.028A
1.811A
499.324
90.985%
1042
31.5
42.32°C
0.989
11.833V
5.044V
3.282V
4.97V
548.796
49.75°C
114.86V
60%
45.662A
5.95A
6.038A
2A
599.789
90.467%
1434
39.4
42.8°C
0.991
11.827V
5.043V
3.28V
4.963V
662.995
50.94°C
114.83V
70%
53.336A
6.944A
7.048A
2.22A
699.582
89.84%
1735
43
43.27°C
0.993
11.821V
5.041V
3.278V
4.956V
778.702
51.08°C
114.79V
80%
61.086A
7.937A
8.059A
2.323A
799.582
89.176%
1896
44.5
43.88°C
0.994
11.814V
5.039V
3.276V
4.951V
896.636
51.7°C
114.75V
90%
69.180A
8.444A
8.55A
2.426A
899.347
88.485%
1900
44.6
44.24°C
0.995
11.808V
5.032V
3.275V
4.947V
1016.383
53.84°C
114.71V
100%
77.079A
8.954A
9.073A
3.045A
999.366
87.547%
1904
44.7
45.14°C
0.996
11.802V
5.024V
3.274V
4.927V
1141.515
56.35°C
114.66V
110%
84.905A
9.956A
10.18A
3.046A
1099.947
86.515%
1908
44.7
47.09°C
0.997
11.798V
5.021V
3.271V
4.925V
1271.396
59.83°C
114.62V
CL1
0.118A
14.574A
15.173A
0A
126.297
82.72%
1868
44.3
40.14°C
0.963
11.867V
5.166V
3.269V
5.027V
152.678
43.82°C
114.99V
CL2
0.118A
23.872A
0A
0A
126.26
82.978%
925
28
40.69°C
0.962
11.864V
5.231V
3.29V
5.027V
152.156
43.46°C
114.99V
CL3
0.117A
0A
25.331A
0A
83.898
74.883%
943
28.5
40.19°C
0.965
11.864V
5.018V
3.257V
5.028V
112.038
44.23°C
115V
CL4
84.754A
0A
0A
0.001A
999.931
88.296%
1908
44.7
45.85°C
0.995
11.798V
4.948V
3.287V
5.012V
1132.488
54.7°C
114.67V
The results above are not used in the certification process
Light Load Tests 115V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.253A
0.495A
0.501A
0.199A
20.01
68.813%
685
18.4
36.72°C
0.748
11.860V
5.054V
3.291V
5.022V
29.079
39.27°C
115.03V
40W
2.758A
0.693A
0.702A
0.299A
40.005
80.421%
688
18.5
37.4°C
0.871
11.857V
5.054V
3.29V
5.019V
49.748
39.62°C
115.02V
60W
4.262A
0.89A
0.903A
0.399A
60.003
84.043%
696
19.4
38.69°C
0.931
11.857V
5.054V
3.29V
5.016V
71.399
40.82°C
115.02V
80W
5.763A
1.088A
1.104A
0.499A
79.954
86.827%
710
19.9
39.42°C
0.954
11.856V
5.053V
3.289V
5.013V
92.09
41.4°C
115.01V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
29.06mV
24.83mV
24.81mV
23.02mV
Pass
20% Load
28.45mV
23.86mV
23.94mV
22.61mV
Pass
30% Load
30.70mV
23.45mV
23.43mV
22.61mV
Pass
40% Load
30.44mV
24.01mV
26.34mV
22.56mV
Pass
50% Load
30.49mV
28.00mV
26.45mV
23.73mV
Pass
60% Load
30.29mV
26.67mV
29.57mV
25.57mV
Pass
70% Load
31.21mV
26.77mV
28.39mV
25.27mV
Pass
80% Load
31.87mV
27.38mV
31.15mV
27.01mV
Pass
90% Load
30.80mV
29.68mV
32.33mV
27.67mV
Pass
100% Load
32.46mV
27.75mV
26.18mV
28.43mV
Pass
110% Load
32.02mV
28.80mV
31.80mV
29.85mV
Pass
Crossload1
28.17mV
26.63mV
33.07mV
20.91mV
Pass
Crossload2
32.33mV
32.80mV
36.73mV
23.43mV
Pass
Crossload3
29.78mV
25.44mV
28.85mV
21.63mV
Pass
Crossload4
31.66mV
25.14mV
23.21mV
27.39mV
Pass
The results above are not used in the certification process