CYBENETICS LTD 塞浦路斯 尼科西亚 拉齐亚 2231 Syrou 6号
Super Flower Leadex VII XG V2 ETA Platinum 1000W
序号S2606199003
Lab IDSF10003371
认证ID263371
  • 测试结果报告ID: 26PS3371A
  • 证书签发日期: Aug 4, 2026
115V230V
认证方案:ETA-EMI PSU
115V230V
认证方案:LAMBDA PSU
验证范围之外
Aristeidis Bitziopoulos, 认证机构总经理

General Information

Test Equipment

DUT Information(Non-accredited measurements)

线材与接头(Non-accredited measurements)

保护功能

电源规格

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary

保持时间 & PWR_OK 信号

待机功耗

Tables

Graphs

转换效率图表

Efficiency and power factor by load range

868788899091929394Average efficiency (%)87.4491.8691.9091.0689.9388.8693.5393.9393.4692.870-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 86115V230V
868788899091929394Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 86115V230V
0.800.820.840.860.880.900.920.940.960.981.00Average power factor0.9560.9890.9950.9960.9970.8320.9540.9730.9830.9870-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.80115V230V
0.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.80115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %233 / 23387.44%88.86%0.9560.832
20-<40 %310 / 31091.86%93.53%0.9890.954
40-<60 %310 / 31091.90%93.93%0.9950.973
60-<80 %310 / 31091.06%93.46%0.9960.983
80-100 %317 / 31789.93%92.87%0.9970.987
70-100 % (High-Load)472 / 47290.23%93.02%0.9960.986
All (published average)1480 / 148090.59%92.72%0.9880.952

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1480 (115V) and 1480 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

噪声图

Noise by load range

High-Load Index (70-100 % load)
Noise 21.2 dB(A) at 115V and 20.5 dB(A) at 230V · loudest point 31.7 dB(A)
Efficiency 90.23% / 93.02% · power factor 0.996 / 0.986 (115V / 230V)
051015202530Average noise (dB(A))<6.0<6.00-<20 %fan off 100%/100%<6.0<6.020-<40 %fan off 98%/99%<6.0<6.040-<60 %fan off 52%/55%11.710.760-<80 %fan off 3%/5%22.721.980-100 %fan off 0%/0%115V230V
051015202530Average noise (dB(A))<6.0<6.00-<20 %off 100%/100%<6.0<6.020-<40 %off 98%/99%<6.0<6.040-<60 %off 52%/55%11.710.760-<80 %off 3%/5%22.721.980-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %<6.0 (<6.0)<6.0 (<6.0)100% / 100%
20-<40 %<6.0 (<6.0)<6.0 (<6.0)98% / 99%
40-<60 %<6.0 (14.1)<6.0 (14.1)52% / 55%
60-<80 %11.7 (22.6)10.7 (20.2)3% / 5%
80-100 %22.7 (31.7)21.9 (28.5)0% / 0%
70-100 % (High-Load)21.2 (31.7)20.5 (28.5)0% / 0%
All (published average)16.5 (31.7)15.8 (28.5)48% / 49%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1480 (115V) and 1480 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

115V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 35.7 °C0 RPM · <6.0 dB(A) · 43.7 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 39.2 °C0 RPM · <6.0 dB(A) · 46.0 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 44.9 °C0 RPM · <6.0 dB(A) · 58.8 °Cfan off in both
100%775 RPM · 25.1 dB(A) · 31.0 °C1130 RPM · 38.3 dB(A) · 45.1 °C+13.2 dB(A)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 31.4 °C0 RPM · <6.0 dB(A) · 42.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 32.7 °C0 RPM · <6.0 dB(A) · 42.8 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 37.7 °C0 RPM · <6.0 dB(A) · 53.0 °Cfan off in both
100%695 RPM · 22.3 dB(A) · 30.9 °C1088 RPM · 35.8 dB(A) · 45.0 °C+13.5 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

传导发射 EN 55032 & CISPR 32

Indicative Performance

高环温电源转换效率

5VSB效率

5VSB效率(ERP LOT 3/6与CEC)

Protection Features

Supplementary Tests (For Reference)

典型负载测试

轻载测试

纹波测量

Super Flower Leadex VII XG V2 ETA Platinum 1000W

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
本测试报告中包含的所有数据和图表,任何个人在满足以下条件时均可使用:
› 应注明测试结果由 Cybenetics 提供
› 在任何情况下均应提供原始测试结果文档的链接
Cybenetics为电源开展自愿性认证项目——ETA针对效率、LAMBDA针对噪音、SAFE针对安全性与正确运行——同时也为散热产品提供认证,其中DELTA针对机箱隔音,PHI针对风扇风量与静压。THETA在ISO 17065与认可范围之外,对AMD AM5和Intel LGA1851平台上的散热器性能进行评级。