CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Thermaltake AX 3200W
序号PSTPA3200FNSAPE1YGCW00074
Lab IDTT32003410
Certification ID263410
  • Test Result Report ID: 26PS3410A
  • Certificate Issue Date: Sep 16, 2026
230V
Scheme: ETA-EMI PSU
230V
No LAMBDA levelAverage noise output 48.47 dB(A), above the 45 dB(A) limit of the lowest LAMBDA level (Standard).
Scheme: LAMBDA PSU
Outside Validation Scope
This product certification body is accredited by CYS-CYSAB (Cyprus Accreditation Body) under accreditation number C010 as a Product Certification Body, in accordance with the recognized International Standard ISO/IEC 17065:2012 “Conformity assessment — Requirements for bodies certifying products, processes and services”. The accreditation covers the ETA and LAMBDA certification of power supply units and of multimedia (information technology) equipment, and the PHI certification of cooling fans, each as a Type 1a scheme according to ISO/IEC 17067. Certifications outside that scope are not covered by the accreditation. This accreditation demonstrates technical competence for a defined scope and the operation of a management system.
Aristeidis Bitziopoulos, Certification Body General Manager
CYS-CYSAB accreditation symbol, ISO/IEC 17065:2012
No. of Accred.: C010
PRODUCT CERTIFICATION

General Information

Test Equipment

DUT Information(Non-accredited measurements)

线材与接头(Non-accredited measurements)

Protection Features

电源规范

Parts Description

Test Results

Temperature & Compliance Info

Performance Summary 230V

保持时间 & PG信号

待机电源

Tables 230V

Graphs 230V

转换效率图表

230V

Efficiency and power factor by load range

878889909192939495Average efficiency (%)88.3494.0593.8692.8691.550-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87230V
878889909192939495Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 87230V
0.900.920.940.960.981.00Average power factor0.9340.9850.9920.9950.9970-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.90230V
0.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.90230V
Load rangePointsEfficiency
230V
PF
230V
0-<20 %29788.34%0.934
20-<40 %32294.05%0.985
40-<60 %32093.86%0.992
60-<80 %31892.86%0.995
80-100 %32491.55%0.997
70-100 % (High-Load)48291.89%0.996
All (published average)158192.19%0.981

INFO

The average efficiency and power factor in five ranges of load. Calculated from the 1581 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 3200 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

噪音值图表

230V

Noise by load range

High-Load Index (70-100 % load)
Noise 53.4 dB(A) at 230V · loudest point 56.5 dB(A)
Efficiency 91.89% · power factor 0.996 (230V)
051015202530354045505560Average noise (dB(A))26.00-<20 %fan off 0%27.320-<40 %fan off 0%32.140-<60 %fan off 0%47.460-<80 %fan off 0%54.680-100 %fan off 0%230V
0102030405060Average noise (dB(A))26.00-<20 %off 0%27.320-<40 %off 0%32.140-<60 %off 0%47.460-<80 %off 0%54.680-100 %off 0%230V
Load rangeNoise 230V
avg (loudest)
Fan off
230V
0-<20 %26.0 (31.2)0%
20-<40 %27.3 (31.2)0%
40-<60 %32.1 (41.9)0%
60-<80 %47.4 (50.8)0%
80-100 %54.6 (56.5)0%
70-100 % (High-Load)53.4 (56.5)0%
All (published average)48.5 (56.5)0%

INFO

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1581 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 3200 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)

230V

LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%426 RPM · 9.7 dB(A) · 30.5 °C447 RPM · 11.8 dB(A) · 40.5 °C+2.1 dB(A)
20%429 RPM · 11.1 dB(A) · 30.2 °C478 RPM · 11.1 dB(A) · 40.6 °C+0.0 dB(A)
50%846 RPM · 24.2 dB(A) · 30.2 °C1385 RPM · 38.4 dB(A) · 42.2 °C+14.2 dB(A)
100%2793 RPM · 56.5 dB(A) · 31.0 °C2917 RPM · 57.1 dB(A) · 47.0 °C+0.6 dB(A)

INFO

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Conducted Emissions EN 55032 & CISPR 32

Indicative Performance

高环温电源转换效率

5Vsb转换效率

输入电压 时的5Vsb 效率 (ErP Lot3/6 & CEC) 230V

Protection Features

Supplementary Tests (For Reference)

10-110%负载测试 230V

20-80瓦负载测试 230V

纹波测量 230V

Thermaltake AX 3200W

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals
本测试报告中包含的所有数据和图表均可在以下条件下由任何人使用:使用过程需提及测试结果由Cybenetics提供。
在任何情况下都应提供原始测试结果文档的网站链接
Cybenetics 提供自愿性认证计划:电源方面有 ETA(效率)、LAMBDA(噪声)与 SAFE(安全与正确运行);散热产品方面有 DELTA(机箱隔音)与 PHI(风扇风量与静压)
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus